aboutsummaryrefslogtreecommitdiffstats
path: root/docs/docs_CCVPN.rst
blob: c1bb8e07d746d35fbfcaddc9bf720468da1f2c1c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
.. This work is licensed under a Creative Commons Attribution 4.0
   International License. http://creativecommons.org/licenses/by/4.0

.. _docs_ccvpn:

:orphan:

CCVPN (Cross Domain and Cross Layer VPN)
----------------------------------------

Update for Guilin Release
~~~~~~~~~~~~~~~~~~~~~~~~~

In Guilin Release, **MDONS** Extension feature is introduced.

In addition to the MDONS extension, CCVPN has also developed an
IETF/ACTN-based Transport Slicing solution (REQ-347). This development
enabled ONAP to offer the TN NSSMF functionality, which was used by
the E2E Network Slicing use case (REQ-342).  The solution was built
upon the existing IETF/ACTN E-LINE over OTN NNI feature developed in Frankfurt release.

Guilin Scope and Impacted modules
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
MDONS Extension implementation for the Frankfurt release will incorporate the following:

- Support Asynchronous OpenRoadM OTN service activation notification handling
- Add OOF support for inter domain link/path selection
- Support Closed Loop sub-use case

Impacted ONAP modules include: OOF, SDN-C, SO and Holmes.

`Wiki link reference <https://wiki.onap.org/display/DW/MDONS+Extension+in+R7>`_

Transport Slicing in Guilin release has implemented the following TN NSSMF functionality:

- Allocate TN NSSI
- Deallocate TN NSSI
- Activate TN NSSI
- Deactivate TN NSSI

The Tranport Slicing implementation has made code changes in the following modules:

- AAI (Schema changes only)
- UUI
- SO
- OOF
- SDN-C
- CCSDK
- Modelling

Functional/Integration Test Cases
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

For integration test case and description of MDONS extension, refer to this
`following wiki-page <https://wiki.onap.org/display/DW/Integration+Test+Cases+-+MDONS+Extension>`_.

For integration test case and description of Transport Slicing:

- `Guilin Test plan <https://wiki.onap.org/display/DW/CCVPN+-+Transport+Slicing+integration+test+plan+for+Guilin+release>`_
- `Guilin E2E Network Slicing <https://wiki.onap.org/display/DW/E2E+Network+Slicing+Use+Case+in+R7+Guilin>`_

Installation Procedure
~~~~~~~~~~~~~~~~~~~~~~

For MDONS extension, the integration test environment is established to have ONAP instance with Guilin
release interfacing to 3rd party transport domain controllers. One controller
instance manages OpenROADM OTN topology and the other 2 instances manage TAPI
OTN topology. L0 infrastructure and WDM services are pre-provisioned to support
L1 topology discovery and OTN service orchestration from ONAP.

For Transport Slicing, the installation procedure is similar to that of the E2E
Network Slicing use case. In other words, we need to bring up the required modules
including SDC, SO, A&AI, UUI and OOF. We also need to configure these modules along
with the mandatory common modules such as DMaaP.

Testing Procedures
~~~~~~~~~~~~~~~~~~

The testing procedure is described in:

- `Testing procedure for MDONS extension <https://wiki.onap.org/display/DW/Integration+Test+Cases+-+MDONS+Extension>`_
- `Testing procedure for Transport Slicing <https://wiki.onap.org/display/DW/CCVPN+-+Transport+Slicing+integration+test+plan+for+Guilin+release>`_

Update for Frankfurt release
~~~~~~~~~~~~~~~~~~~~~~~~~~~~

In Frankfurt, we introduced two extensions in CCVPN use case. One is E-LINE service over OTN NNI handover, another is the
multi domain optical service which aims to provide end to end layer 1 service.

E-LINE over OTN NNI
~~~~~~~~~~~~~~~~~~~

Description
~~~~~~~~~~~

It is considered a typical scenario for operators to use OTN to interconnect its multiple transport network domains. Hence
the capabilities of orchestrating end-to-end E-LINE services across the domains over OTN is important for ONAP.  When operating
with multiple domains with multi vendor solutions, it is also important to define and use standard and open
interfaces, such as the IETF ACTN-based transport `YANG models <https://tools.ietf.org/html/rfc8345>`_, as the southbound interface
of ONAP, in order to ensure interoperability. The SOTN NNI use-case aims to automate the design, service provision by independent
operational entities within a service provider network by delivering E-Line over OTN orchestration capabilities into ONAP. SOTN NNI
extends upon the CCVPN use-case by incorporating support for L1/L2 network management capabilities leveraging open standards & common
data models.

Frankfurt Scope and Impacted modules
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The Frankfurt demonstration includes L1(OTN) and L2(ETH) Topology discovery from multiple domains controllers with in an operator
and provide VPN service provision in OTN and ETH network.

The ONAP components involved in this use case are: SDC, A&AI, UUI, SO, SDNC, OOF, MSB.

Functional Test Cases
~~~~~~~~~~~~~~~~~~~~~

Usecase specific developments have been realized in SO, OOF, AAI, SDNC and UUI ONAP components..

Testing Procedure
~~~~~~~~~~~~~~~~~
Design time
SOTNVPNInfraService service design in SDC and distribute to AAI and SO.

Run Time:
All operation will be triggered by UUI, including service creation and termination,
link management and topology network display:

- `E-LINE over OTN Inter Domain Test Cases <https://wiki.onap.org/display/DW/E-LINE+over+OTN+Inter+Domain+Test+Cases>`_
- `Testing status <https://wiki.onap.org/display/DW/2%3A+Frankfurt+Release+Integration+Testing+Status>`_

MDONS (Multi-Domain Optical Network Services)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Overall Description
~~~~~~~~~~~~~~~~~~~

The MDONS use-case aims to automate the design, activation & operations resulting
from an optical transport (L0/L1) service request exchange between service providers and/or independent operational entities within a service provider network by delivering E2E optical orchestration capabilities into ONAP. MDONS extends upon the CCVPN use-case by incorporating support for L0/L1 network management capabilities leveraging open standards & common data models defined by OpenROADM, Transport-API & MEF.

Frankfurt Scope and Impacted modules
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

MDONS implementation for the Frankfurt release will incorporate the following:
- Design & modelling of optical services based on MEF L1 subscriber & operator properties
- E2E optical service workflow definitions for service instantiation & deletion
- UI portal with L1 service instantiation templates
- Optical Transport domain management (topology, resource onboarding) through standard models / APIs - OpenROADM, T-API
Impacted ONAP modules include: A&AI, SDC, SDN-C, SO, UUI

References:

- `OpenROADM reference <https://github.com/OpenROADM/OpenROADM_MSA_Public>`_
- `ONF Transport-API (TAPI) <https://github.com/OpenNetworkingFoundation/TAPI>`_
- `MEF <https://wiki.mef.net/display/CESG/MEF+63+-+Subscriber+Layer+1+Service+Attributes>`_

Functional/Integration Test Cases
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

For integration test case and description, refer to this following
`wiki-page <https://wiki.onap.org/display/DW/MDONS+Integration+Test+Case>`_.

Installation Procedure
~~~~~~~~~~~~~~~~~~~~~~

The integration test environment is established to have ONAP instance with
Frankfurt release interfacing to 3rd party transport domain controllers.
One controller instance manages OpenROADM OTN topology and the other 2 instances
manage TAPI OTN topology. L0 infrastructure and WDM services are pre-provisioned
to support L1 topology discovery and OTN service orchestration from ONAP.

Testing Procedure
~~~~~~~~~~~~~~~~~

Test environment is described in
`Installation and Test Procedure <https://wiki.onap.org/display/DW/MDONS+Integration+Test+Case>`_.

Update for Dublin release
~~~~~~~~~~~~~~~~~~~~~~~~~

1. Service model optimization

In Dublin release,the design of CCVPN was optimized by having support of List type of Input in SDC.
During onboarding and design phase, one end to end service is created using SDC.
This service is composed of these two kinds of resources:

- VPN resource
- Site resource

See the `Details of Targeted Service Template wiki page <https://wiki.onap.org/display/DW/Details+of+Targeted+Service+Template>`_
for details.

2. Closed Loop in bandwidth adjustment
Simulate alarm at the edge site branch and ONAP will execute close-loop automatically and trigger bandwidth to change higher.

3. Site Change
Site can be add or delete according to the requirements

More information about:

- `CCVPN in Dublin release <https://wiki.onap.org/pages/viewpage.action?pageId=45296665>`_
- `Dublin test cases <https://wiki.onap.org/display/DW/CCVPN+Test+Cases+for+Dublin+Release>`_
- `CCVPN Test Status wiki page <https://wiki.onap.org/display/DW/CCVPN+Test+Status>`_

.. note::
    CCVPN integration testing coversed service design, service creation and
    closed-loop bandwidth adjustments in Dublin release.

    The service termination and service change will continue to be tested in E release.
    During the integration testing, SDC, SO, SDC master branch are used which
    includes the enhanced features for CCVPN use case.

Service used for CCVPN
~~~~~~~~~~~~~~~~~~~~~~

- `SOTNVPNInfraService, SDWANVPNInfraService and SIteService <https://wiki.onap.org/display/DW/CCVPN+Service+Design>`_
- `WanConnectionService (Another way to describe CCVPN in a single service form which based on ONF CIM <https://wiki.onap.org/display/DW/CCVPN+Wan+Connection+Service+Design>`_

Description
~~~~~~~~~~~

Cross-domain, cross-layer VPN (CCVPN) is one of the use cases of the ONAP
Casablanca release. This release demonstrates cross-operator ONAP orchestration
and interoperability with third party SDN controllers and enables cross-domain,
cross-layer and cross-operator service creation and assurance.

The demonstration includes two ONAP instances, one deployed by Vodafone and one
by China Mobile, both of which orchestrate the respective operator underlay OTN
networks and overlay SD-WAN networks and peer to each other for cross-operator
VPN service delivery.

`CCVPN Use Case Wiki Page <https://wiki.onap.org/display/DW/CCVPN%28Cross+Domain+and+Cross+Layer+VPN%29+USE+CASE>`_

The projects covered by this use case include: SDC, A&AI, UUI, SO, SDNC, OOF, Policy, DCAE(Holmes), External API, MSB

How to Use
~~~~~~~~~~

Design time:

- `SOTNVPNInfraService, SDWANVPNInfraService and SIteService service Design steps <https://wiki.onap.org/display/DW/CCVPN+Service+Design>`_
- `WanConnectionService ( Another way to describe CCVPN in a single service form which based on ONF CIM ) <https://wiki.onap.org/display/DW/CCVPN+Wan+Connection+Service+Design>`_

Run Time:

- All operations will be triggered by UUI, including service creation and termination,
  link management and topology network display.


See the `CCVPN Test Guide wiki page <https://wiki.onap.org/display/DW/CCVPN+Test+Guide>`_
for details.

Test Status and Plans
~~~~~~~~~~~~~~~~~~~~~

- `All test case covered by this use case <https://wiki.onap.org/display/DW/CCVPN+Integration+Test+Case>`_
- `Test status <https://wiki.onap.org/display/DW/CCVPN++-Test+Status>`_

Known Issues and Resolutions
~~~~~~~~~~~~~~~~~~~~~~~~~~~~

1) AAI-1923. Link Management, UUI can't delete the link to external onap otn domain.

For the manual steps provided by A&AI team, we should follow the steps as follow
the only way to delete is using the forceDeleteTool shell script in the graphadmin container.
First we will need to find the vertex id, you should be able to get the id by making the following GET request.

GET /aai/v14/network/ext-aai-networks/ext-aai-network/createAndDelete/esr-system-info/test-esr-system-info-id-val-0?format=raw

.. code-block:: JSON

  {

    "results": [
      {
        "id": "20624",
        "node-type": "pserver",
        "url": "/aai/v13/cloud-infrastructure/pservers/pserver/pserverid14503-as988q",
        "properties": {}
      }
    ]
  }


Same goes for the ext-aai-network:

GET /aai/v14/network/ext-aai-networks/ext-aai-network/createAndDelete?format=raw

Retrieve the id from the above output as that will be the vertex id that you want to remove.

Run the following command multiple times for both the esr-system-info and ext-aai-network:

::

  kubectl exec -it $(kubectl get pods -lapp=aai-graphadmin -n onap --template 'range .items.metadata.name"\n"end' | head -1) -n onap gosu aaiadmin /opt/app/aai-graphadmin/scripts/forceDeleteTool.sh -action DELETE_NODE -userId YOUR_ID_ANY_VALUE -vertexId VERTEX_ID

From the above, remove the YOUR_ID_ANY_VALUE and VERTEX_ID with your info.

2) SDC-1955. Site service Distribution

To overcome the Service distribution, the SO catalog has to be populated with the model information of the services and resources.
a) Refering to the Csar that is generated in the SDC designed as per the details mentioned in the below link: https://wiki.onap.org/display/DW/CCVPN+Service+Design
b) Download the Csar from SDC thus generated.
c) copy the csar to SO sdc controller pod and bpmn pod

.. code-block:: bash

  kubectl -n onap get pod|grep so
  kubectl -n onap exec -it dev-so-so-sdc-controller-c949f5fbd-qhfbl  /bin/sh
  mkdir null/ASDC
  mkdir null/ASDC/1
  kubectl -n onap cp service-Sdwanvpninfraservice-csar.csar  dev-so-so-bpmn-infra-58796498cf-6pzmz:null/ASDC/1/service-Sdwanvpninfraservice-csar.csar
  kubectl -n onap cp service-Sdwanvpninfraservice-csar.csar  dev-so-so-bpmn-infra-58796498cf-6pzmz:ASDC/1/service-Sdwanvpninfraservice-csar.csar

d) populate model information to SO db: the db script example can be seen in
   https://wiki.onap.org/display/DW/Manual+steps+for+CCVPN+Integration+Testing

The same would also be applicable for the integration of the client to create the service and get the details.
Currently the testing has been performed using the postman calls to the corresponding APIs.

3) SDC-1955 & SDC-1958. Site service parsing Error

UUI: stored the csar which created based on beijing release under a fixed directory, If site servive can't parsed by SDC tosca parser, UUI will parse this default csar and get the input parameter
a) Make an available csar file for CCVPN use case.
b) Replace uuid of available files with what existing in SDC.
c) Put available csar files in UUI local path (/home/uui).

4) SO docker branch 1.3.5 has fixes for the issues 1SO-1248

After SDC distribution success, copy all csar files from so-sdc-controller:

- connect to so-sdc-controller ( eg: kubectl.exe exec -it -n onap dev-so-so-sdc-controller-77df99bbc9-stqdz /bin/sh )
- find out all csar files ( eg: find / -name "\*.csar" ), the csar files should
  be in this path: /app/null/ASDC/ ( eg: /app/null/ASDC/1/service-Sotnvpninfraservice-csar.csar )
- exit from the so-sdc-controller ( eg: exit )
- copy all csar files to local derectory ( eg: kubectl.exe cp onap/dev-so-so-sdc-controller-6dfdbff76c-64nf9:/app/null/ASDC/tmp/service-DemoService-csar.csar service-DemoService-csar.csar -c so-sdc-controller )

Copy csar files, which got from so-sdc-controller, to so-bpmn-infra:

- connect to so-bpmn-infra ( eg: kubectl.exe -n onap exec -it dev-so-so-bpmn-infra-54db5cd955-h7f5s -c so-bpmn-infra /bin/sh )
- check the /app/ASDC directory, if doesn't exist, create it ( eg: mkdir /app/ASDC -p )
- exit from the so-bpmn-infra ( eg: exit )
- copy all csar files to so-bpmn-infra ( eg: kubectl.exe cp service-Siteservice-csar.csar onap/dev-so-so-bpmn-infra-54db5cd955-h7f5s:/app/ASDC/1/service-Siteservice-csar.csar )