aboutsummaryrefslogtreecommitdiffstats
path: root/openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml
diff options
context:
space:
mode:
Diffstat (limited to 'openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml')
-rw-r--r--openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml162
1 files changed, 88 insertions, 74 deletions
diff --git a/openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml b/openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml
index 13006c7a6e..3b803ba26b 100644
--- a/openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml
+++ b/openecomp-be/lib/openecomp-sdc-translator-lib/openecomp-sdc-translator-core/src/test/resources/mock/services/heattotosca/fulltest/subinterface/vlantagging/pattern1c1/allConnectivities/out/Nested_vdbeServiceTemplate.yaml
@@ -16,11 +16,6 @@ topology_template:
required: true
entry_schema:
type: string
- subinterface_vlan1_ip_v6_address:
- type: list
- required: true
- entry_schema:
- type: string
subinterface_vlan1_aap_sec_untrusted_ip_prefix:
type: list
required: true
@@ -31,11 +26,6 @@ topology_template:
required: true
entry_schema:
type: string
- subinterface_vlan1_aap_untrusted_ip_prefix:
- type: list
- required: true
- entry_schema:
- type: string
port_vdbe_untr_2_port_virtual_machine_interface_mac_addresses:
type: list
required: true
@@ -47,63 +37,126 @@ topology_template:
vm_flavor_name:
type: string
required: true
- port_vdbe_untr_2_port_virtual_network_refs:
+ subinterface_vlan1_counter:
type: list
required: true
entry_schema:
- type: json
- subinterface_vlan1_counter:
+ type: float
+ vm_image_name:
+ type: string
+ required: true
+ port_vdbe_untr_2_port_network_role:
+ type: string
+ required: true
+ compute_vdbe_metadata:
type: list
required: true
entry_schema:
- type: float
- subinterface_vlan1_subinterfaces_name_prefix:
+ type: json
+ subinterface_vlan1_aap_untrusted_v6_ip_prefix_len:
type: list
required: true
entry_schema:
type: string
- vm_image_name:
- type: string
+ port_vdbe_untr_1_port_ip_requirements:
+ type: list
required: true
- port_vdbe_untr_1_port_network_role:
+ entry_schema:
+ type: org.openecomp.datatypes.network.IpRequirements
+ port_vdbe_untr_2_port_vlan_requirements:
+ type: list
+ required: true
+ entry_schema:
+ type: org.openecomp.datatypes.network.VlanRequirements
+ port_vdbe_untr_2_port_exCP_naming:
+ type: org.openecomp.datatypes.Naming
+ required: true
+ port_vdbe_untr_2_port_ip_requirements:
+ type: list
+ required: true
+ entry_schema:
+ type: org.openecomp.datatypes.network.IpRequirements
+ port_vdbe_untr_1_port_mac_requirements:
+ type: org.openecomp.datatypes.network.MacRequirements
+ required: true
+ port_vdbe_untr_1_port_order:
+ type: integer
+ required: true
+ port_vdbe_untr_1_port_subnetpoolid:
type: string
required: true
- port_vdbe_untr_2_port_name:
+ port_vdbe_untr_2_port_mac_requirements:
+ type: org.openecomp.datatypes.network.MacRequirements
+ required: true
+ port_vdbe_untr_1_port_virtual_machine_interface_allowed_address_pairs:
+ type: org.openecomp.datatypes.heat.contrailV2.virtual.machine.subInterface.AddressPairs
+ required: true
+ subinterface_vlan1_mac_address:
type: list
required: true
entry_schema:
type: string
- port_vdbe_untr_2_port_network_role:
+ subinterface_vlan1_aap_untrusted_ip_prefix_len:
+ type: list
+ required: true
+ entry_schema:
+ type: string
+ subinterface_vlan1_ip_address:
+ type: list
+ required: true
+ entry_schema:
+ type: string
+ compute_vdbe_name:
+ type: list
+ required: true
+ entry_schema:
+ type: string
+ port_vdbe_untr_1_port_network_role_tag:
type: string
required: true
- compute_vdbe_metadata:
+ subinterface_vlan1_ip_v6_address:
type: list
required: true
entry_schema:
- type: json
- subinterface_vlan1_aap_untrusted_v6_ip_prefix_len:
+ type: string
+ port_vdbe_untr_1_port_related_networks:
+ type: list
+ required: true
+ entry_schema:
+ type: org.openecomp.datatypes.network.RelatedNetworksAssignments
+ subinterface_vlan1_aap_untrusted_ip_prefix:
type: list
required: true
entry_schema:
type: string
- port_vdbe_untr_1_port_virtual_network_refs:
+ port_vdbe_untr_2_port_virtual_network_refs:
type: list
required: true
entry_schema:
type: json
- port_vdbe_untr_1_port_ip_requirements:
+ subinterface_vlan1_subinterfaces_name_prefix:
type: list
required: true
entry_schema:
- type: org.openecomp.datatypes.network.IpRequirements
- port_vdbe_untr_2_port_vlan_requirements:
+ type: string
+ port_vdbe_untr_1_port_network_role:
+ type: string
+ required: true
+ port_vdbe_untr_2_port_name:
type: list
required: true
entry_schema:
- type: org.openecomp.datatypes.network.VlanRequirements
- port_vdbe_untr_2_port_exCP_naming:
- type: org.openecomp.datatypes.Naming
+ type: string
+ port_vdbe_untr_2_port_related_networks:
+ type: list
required: true
+ entry_schema:
+ type: org.openecomp.datatypes.network.RelatedNetworksAssignments
+ port_vdbe_untr_1_port_virtual_network_refs:
+ type: list
+ required: true
+ entry_schema:
+ type: json
subinterface_vlan1_vn_network_list:
type: list
required: true
@@ -120,17 +173,6 @@ topology_template:
required: true
entry_schema:
type: float
- port_vdbe_untr_2_port_ip_requirements:
- type: list
- required: true
- entry_schema:
- type: org.openecomp.datatypes.network.IpRequirements
- port_vdbe_untr_1_port_mac_requirements:
- type: org.openecomp.datatypes.network.MacRequirements
- required: true
- port_vdbe_untr_1_port_order:
- type: integer
- required: true
subinterface_vlan1_parent_interface:
type: list
required: true
@@ -151,9 +193,6 @@ topology_template:
port_vdbe_untr_1_port_exCP_naming:
type: org.openecomp.datatypes.Naming
required: true
- port_vdbe_untr_1_port_subnetpoolid:
- type: string
- required: true
subinterface_vlan1_optional_property_1:
type: list
required: true
@@ -164,48 +203,19 @@ topology_template:
required: true
entry_schema:
type: string
- port_vdbe_untr_2_port_mac_requirements:
- type: org.openecomp.datatypes.network.MacRequirements
- required: true
subinterface_vlan1_optional_property_2:
type: list
required: true
entry_schema:
type: string
- port_vdbe_untr_1_port_virtual_machine_interface_allowed_address_pairs:
- type: org.openecomp.datatypes.heat.contrailV2.virtual.machine.subInterface.AddressPairs
- required: true
subinterface_vlan1_aap_sec_untrusted_ip_prefix_len:
type: list
required: true
entry_schema:
type: string
- subinterface_vlan1_mac_address:
- type: list
- required: true
- entry_schema:
- type: string
- subinterface_vlan1_aap_untrusted_ip_prefix_len:
- type: list
- required: true
- entry_schema:
- type: string
- subinterface_vlan1_ip_address:
- type: list
- required: true
- entry_schema:
- type: string
port_vdbe_untr_2_port_virtual_machine_interface_allowed_address_pairs:
type: org.openecomp.datatypes.heat.contrailV2.virtual.machine.subInterface.AddressPairs
required: true
- compute_vdbe_name:
- type: list
- required: true
- entry_schema:
- type: string
- port_vdbe_untr_1_port_network_role_tag:
- type: string
- required: true
port_vdbe_untr_1_port_vlan_requirements:
type: list
required: true
@@ -257,6 +267,8 @@ topology_template:
vlan_requirements:
get_input: port_vdbe_untr_2_port_vlan_requirements
subinterface_indicator: false
+ related_networks:
+ get_input: port_vdbe_untr_2_port_related_networks
virtual_network_refs:
get_input:
- port_vdbe_untr_2_port_virtual_network_refs
@@ -387,6 +399,8 @@ topology_template:
vlan_requirements:
get_input: port_vdbe_untr_1_port_vlan_requirements
subinterface_indicator: true
+ related_networks:
+ get_input: port_vdbe_untr_1_port_related_networks
virtual_network_refs:
get_input:
- port_vdbe_untr_1_port_virtual_network_refs
@@ -644,4 +658,4 @@ topology_template:
- dependency
subinterface_link_vdbe_untr_x_vlan1-Network-Role_vmi_subport_vdbe_vdbe_untr_1_port_vlan1:
- vdbe_vdbe_untr_1_port_vlan1
- - subinterface_link_vdbe_untr_x_vlan1-Network-Role_vmi_subport
+ - subinterface_link_vdbe_untr_x_vlan1-Network-Role_vmi_subport \ No newline at end of file