Age | Commit message (Collapse) | Author | Files | Lines |
|
Previously "clean" target failed if there were no build artifacts. Now
their absence is ignored.
Issue-ID: SECCOM-235
Change-Id: I47beb2754a893e8b7453611116b4da2e516cca90
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch also adds convenience target to the Makefile and updates
documentation on relevant dependencies.
Issue-ID: SECCOM-235
Change-Id: I57e00af3cd4c60af3128e3094607cc61bc1e5dbe
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
According to kube-apiserver documentation [1] and CIS guideline 1.1.4
option "--kubelet-https=" might be absent in API server configuration.
It has secure configuration (being set to "true") by default.
[1] https://kubernetes.io/docs/reference/command-line-tools-reference/kube-apiserver/
Issue-ID: SECCOM-235
Change-Id: I604cdcace03f65185aab6a0b34d48cfec94277ab
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
Apparently Linux AMD64 machines are not the only ones used for ONAP
development (author meant no harm).
Issue-ID: SECCOM-235
Change-Id: Ia78a02fb82dc5752d6b8fd2cef8e6ef583fd3ca6
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
Having Rancher CLI proves itself useful on development machines as well.
Issue-ID: SECCOM-235
Change-Id: I0de3109e1236cf6dc9cbc825342593041dcfdf2c
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
Issue-ID: SECCOM-235
Change-Id: I46e2f8d61c3a82613b665fb6d9b57431bb2a1868
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch adds simplified ONAP deployment environment (Kubernetes
cluster managed by Rancher). Its purpose is to provide cluster defaults
for inspection without the need to access actual ONAP application
deployment.
Default node customization scripts were extracted
("tools/get_customization_scripts.sh" run within "tools/imported/"
directory) from official documentation [1] and imported here in order
not to introduce runtime online dependencies.
This environment should probably be migrated in future to more
appropriate place like devtool [2] (or at least use the same Vagrant
boxes).
[1] https://docs.onap.org/en/casablanca/submodules/oom.git/docs/oom_setup_kubernetes_rancher.html
[2] https://git.onap.org/integration/devtool
Issue-ID: SECCOM-235
Change-Id: I57f9f3caac0e8b391e9ed480f6bebba98e006882
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch verifies if CIS Kubernetes Benchmark v1.3.0 sections
regarding master node configuration are satisfied (1.1.6 and 1.1.7).
Issue-ID: SECCOM-235
Change-Id: I5f215a6642b177e85d7e1c70860ba0c7e558ec4e
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch verifies if CIS Kubernetes Benchmark v1.3.0 sections
regarding master node configuration are satisfied (1.1.1 - 1.1.5, 1.1.8,
1.1.9, 1.1.20 and 1.1.23).
Issue-ID: SECCOM-235
Change-Id: Ib964b5111b616a891c3963ef9695af660810e8ba
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
Issue-ID: SECCOM-235
Change-Id: I370636220151a5755f467055418f866afe11d5d9
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch introduces Rancher queries using its CLI client. It depends
on having utility binary located in PATH and providing configuration
file prior first use.
Issue-ID: SECCOM-235
Change-Id: Idb011e27b4801c5700b4482656463849736298da
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
This patch introduces CLI utility for checking if Kubernetes cluster
follows security recommendations. Provided Makefile simplifies setup
process by setting appropriate environment variables for the build.
Further information can be found in README. Provided symlink allows
proper document rendering on VCS hosting site.
Issue-ID: SECCOM-235
Change-Id: I4a1337c9834322ee4fd742a9ccb979b9bc505f75
Signed-off-by: Pawel Wieczorek <p.wieczorek2@samsung.com>
|
|
When nmap or other commands are not installed on the system
script fail silently without any information
Signed-off-by: Lucjan Bryndza <l.bryndza@samsung.com>
Change-Id: I599b987e223f88617aefa2c0de6cdcbbf3ff50b7
Issue-ID: SECCOM-231
|
|
As it turned out thanks to Yan Yang some ONAP services tend to
return a propr JDWP handshake as a part of their error message.
Let's filter out those services by checking number of lines returned
by the server. We expect that proper JDWP handshake won't be longer
than a single line.
Issue-ID: SECCOM-231
Change-Id: I4b8950ebdf5fe118ec5f2dd5f4de583211784fb2
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|
|
Some of web services do not send any data when challenged with JDWP
challenge. This makes the script waiting forever for response.
To fix that let's introduce 10s timeout (experimental value) and
replace empty string with a new line to avoid bash warnings.
Issue-ID: SECCOM-231
Change-Id: I35546c001c5c54f298e8a4e346c2cf5d41e230ac
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|
|
With the introduction of RKE instead of rancher format of pod
description has slightly changed (annotations). Let's addjust
our security tests to work correctly with recent ONAP release.
Issue-ID: SECCOM-231
Change-Id: I49cdfcae9ce41a2b4bd4969958eddfaffe75b437
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|
|
It is more obvious to use first node in cluster instead of
last one. Additionally in some cases nodes listed in the end
may not expose all open ports (like it is in integration lab).
Issue-ID: SECCOM-231
Change-Id: I200998b2e7b3a6de9b5f464e59e3b7dbbc0a656c
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|
|
ONAP should not expose any open JDWP ports even inside a cluser.
Let's start enforcing this by adding test script to integration which
will find all open JDWP ports.
Based on initial work by:
Radoslaw Zeszczuk <r.zeszczuk@samsung.com>
Issue-ID: SECCOM-231
Change-Id: Ica46faad55850c74ed24728d54f6afdb3301a6d2
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|
|
ONAP should not exposed any http ports, https should be used instead.
Let's start enforcing this by adding test script to integration which
will find all http ports exposed outside of cluster.
Issue-ID: SECCOM-231
Change-Id: I88e4b7890aaaa1bea06b496a6f97f4d5e9771215
Signed-off-by: Krzysztof Opasiak <k.opasiak@samsung.com>
|