.. contents::
:depth: 3
..
SDN-R WT Service Configuration parameters
=========================================
ODL is operated as a cluster. The configuration settings must be the
same for each cluster node.
- `Sections <#SDN-RWTServiceConfigurationparameters-S>`__
- `toggleAlarmFilter <#SDN-RWTServiceConfigurationparameters-t>`__
- `devicemonitor <#SDN-RWTServiceConfigurationparameters-d>`__
Backgrounds regarding the container inter structure is described
in \ :doc:`SDN-R Docker Image configuration <sdnr_Docker_Image_configuration>`.
The configuration information of sdnr wireless transport parameters are
in a single file.
For different devicemanager services, like DeviceMonitor there are
individual sections in the configuration file available.
Configuration file location:
***$ODL\_HOME/etc/devicemanager.properties***
If SDN-R WT is starting
- and the file exists, the configuration is used.
- if it does not exist it will be created with the default parameters.
Below an example of the content.
- Example
::
[toggleAlarmFilter]
taEnabled=true
taDelay=3000
[es]
esCluster=sdnr
esArchiveCheckIntervalSeconds=0
esArchiveLifetimeSeconds=2592000
[dcae]
dcaeUrl=off
dcaeUserCredentials=admin:admin
dcaeHeartbeatPeriodSeconds=120
[aai]
aaiUrl=off
aaiUserCredentials=
aaiHeaders=["X-TransactionId: 9999"]
aaiDeleteOnMountpointRemove=false
aaiTrustAllCerts=false
aaiPropertiesFile=
aaiApiVersion=aai/v13
aaiApplicationId=SDNR
aaiClientConnectionTimeout=30000
aaiPcks12ClientCertFile=
aaiPcks12ClientCertPassphrase=
[pm]
pmEnabled=true
pmCluster=sdnr
[devicemonitor]
SeverityconnectionLossOAM=Major
SeverityconnectionLossMediator=Major
SeverityconnectionLossNeOAM=Major
Sections
--------
toggleAlarmFilter
~~~~~~~~~~~~~~~~~
Configure toggle alarm filter.
taEnabled=true taDelay=3000
+-----------------+---------------+---------------+----------------+------------------------------------------------------+
| **Parameter** | **Values** | **Default** | **Unit** | **Description** |
+=================+===============+===============+================+======================================================+
| taEnabled | true, false | false | | Enable or disable this service |
+-----------------+---------------+---------------+----------------+------------------------------------------------------+
| taDelay | number | | milliseconds | Integration time to take over the new alarm status |
+-----------------+---------------+---------------+----------------+------------------------------------------------------+
devicemonitor
~~~~~~~~~~~~~
Configure alarm severity of related alarms, generated by Device Monitor.
`SDNC-616 <https://jira.onap.org/browse/SDNC-616>`__ - SDN-R WT app need to change alarm severity "Configurable" for ConnectionLossxxx alarm family (received from Mediator) , when it passed to DCAE VES collector.
Syntax: Parameter=Value
Example: SeverityconnectionLossOAM=Major
+----------------------------------+-----------------------------------------------+---------------+------------+--------------------------------------------------------------+
| | **Values** | **Default** | **Unit** | **Description** |
+==================================+===============================================+===============+============+==============================================================+
| SeverityconnectionLossOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | | SDN-Controller <> Mediator |
| | | | | |
| | | | | Mountpoint monitoring. Indicates a not connected mounpoint |
+----------------------------------+-----------------------------------------------+---------------+------------+--------------------------------------------------------------+
| SeverityconnectionLossMediator | NonAlarmed, Warning, Minor, Major, Critical | Major | | SDN-Controller <> NetworkElement |
| | | | | |
| | | | | Device monitoring. No LTPs provided |
+----------------------------------+-----------------------------------------------+---------------+------------+--------------------------------------------------------------+
| SeverityconnectionLossNeOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | | SDN-Controller <> NetworkElement |
| | | | | |
| | | | | Device monitoring. SSH Connetion, Core model not answering |
+----------------------------------+-----------------------------------------------+---------------+------------+--------------------------------------------------------------+
|