diff options
author | Bozawglanian, Hagop (hb755d) <hb755d@att.com> | 2018-04-03 21:46:51 +0000 |
---|---|---|
committer | Bozawglanian, Hagop (hb755d) <hb755d@att.com> | 2018-04-03 21:47:47 +0000 |
commit | 098e11375d5a8be05865974b59afd7772c9dc852 (patch) | |
tree | b7788639240b53a07240d4b57cfc84cdd06dd873 /docs/manual_use_case.rst | |
parent | ac41171529fa474302fc47baf272712b542c15f2 (diff) |
VNFRQTS - Use Case setup
Manual Scale out use case first use case to be added.
Change-Id: Iadebeee519c5c41af7d22b0522934e1237cedb37
Issue-ID: VNFRQTS-154
Signed-off-by: Bozawglanian, Hagop (hb755d) <hb755d@att.com>
Diffstat (limited to 'docs/manual_use_case.rst')
-rw-r--r-- | docs/manual_use_case.rst | 44 |
1 files changed, 44 insertions, 0 deletions
diff --git a/docs/manual_use_case.rst b/docs/manual_use_case.rst new file mode 100644 index 0000000..46e3b12 --- /dev/null +++ b/docs/manual_use_case.rst @@ -0,0 +1,44 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. Copyright 2017 ONAP + + +.. contents:: + :local: + +**Manual Scale Out Use Case** +================================== + +(VNF Perspective) + +In its Beijing Release, ONAP will support the ability to manually scale out VNF Components. Below is the Sequence Diagram for how Manual Scale Out will work in ONAP. + +|image0| + +Description of Workflow +--------------------------------------------- + +At a high level the way Manual Scale Out will work is: + 1. Using VID, the operator will choose to scale out a VNFC by picking a VF_Module to scale and choosing which controller is responsible for that VNF. + 2. VID sends the Scale Out Request to SO. + 3. When SO receives the Scaling request it will first send a request to the appropriate controller (APPC or SDNC) to execute a Healthcheck on the VNF. + 4. Once the Healthcheck has been run, SO executes the Heat Template associated with the VF Module requested by the VID Operator. + 5. After the new component(s) have been instantiated SO calls the responsible controller (via DMaaP) to configure the new instances. + 6. Finally a Healthcheck is run to ensure that the entire VNF is Operating as it should. + + +VNF Impacts +------------------------ + +For VNFs to make use of the Manual Scaling Capabilities of ONAP, they must support the following functionality: + 1. VNFs must support a Healthcheck as described in: `The Management Section of the ONAP VNF Guidelines <http://onap.readthedocs.io/en/latest/submodules/vnfrqts/requirements.git/docs/Chapter7.html#vnf-rest-apis>`_. + a. R-31809 is the requirement dictating the need for VNF Healthchecks. + b. The Ansible Healthcheck Playbook description may be found in `The Ansible Standards and Capabilities Section <http://onap.readthedocs.io/en/latest/submodules/vnfrqts/requirements.git/docs/Chapter7.html#ansible-standards-and-capabilities>`_. + 2. VNF Heat Templates must be built according the `VNF Modularity Rules <http://onap.readthedocs.io/en/latest/submodules/vnfrqts/requirements.git/docs/Chapter4.html#d-vnf-modularity>`_. + a. The VF_Module to be scaled must be built according the VNF Modularity Rules for Incremental Modules. + 3. Configuration of the VNF must be done via NETCONF, Chef, or Ansible as described in `Configuration Management <http://onap.readthedocs.io/en/latest/submodules/vnfrqts/requirements.git/docs/Chapter7.html#c-configuration-management>`_. + + +.. |image0| image:: Scale_Out_Workflow.png + :width: 7in + :height: 9in |