diff options
author | Lovett, Trevor <trevor.lovett@att.com> | 2019-10-01 14:08:25 -0500 |
---|---|---|
committer | stark, steven <steven.stark@att.com> | 2019-10-01 12:22:49 -0700 |
commit | 9dc950cfd200fc107e1a9c96da0434b904963d6b (patch) | |
tree | af4ab1898dfbf5543456244f6ac5dbce27f7dcf2 /docs | |
parent | 726fd64acda27c2d1eca946284c69ba646b97cba (diff) |
Updating Heat Instantiation Pass/Fail Criteria
Issue-ID: VNFRQTS-734
Signed-off-by: Lovett, Trevor <trevor.lovett@att.com>
Change-Id: Ida6daaf9a9176411ced2dcaf44f56cc0778d0404
Signed-off-by: stark, steven <steven.stark@att.com>
Diffstat (limited to 'docs')
-rw-r--r-- | docs/OnboardInstantiateTests.rst | 52 |
1 files changed, 26 insertions, 26 deletions
diff --git a/docs/OnboardInstantiateTests.rst b/docs/OnboardInstantiateTests.rst index d1bb71b..abe5e29 100644 --- a/docs/OnboardInstantiateTests.rst +++ b/docs/OnboardInstantiateTests.rst @@ -97,8 +97,8 @@ Assumptions comprise multiple VNFs is beyond the scope of this specification. * The **Test Engine** will have access to the ONAP APIs in terms of both network connectivity and API access. -* All instantiations will use the ONAP Generic Resource API from SDNC instead - of the legacy VNF API. +* VNF Instantiation for either ONAP legacy VNF API or Generic Resource API is + supported. Prerequisites @@ -170,56 +170,56 @@ documentation of the **Test Engine**. **Steps** -1. Create the generic Vendor License Model (VLM) in SDC +1. Execute VVP validation scripts to ensure VNF Heat Templates are compliant + with the VNF Heat Template Requirements. -2. Create the Vendor Software Product (VSP) in SDC. The VSP will be +2. Create the generic Vendor License Model (VLM) in SDC + +3. Create the Vendor Software Product (VSP) in SDC. The VSP will be auto-assigned a unique name to avoid collisions with other VSPs in the lab environment. -3. Upload the ONAP-compliant Heat archive (zip file) as an artifact of the VSP in SDC. +4. Upload the ONAP-compliant Heat archive (zip file) as an artifact of the VSP in SDC. -4. Assign any "Unassigned Files" in SDC to Artifacts +5. Assign any "Unassigned Files" in SDC to Artifacts -5. Validate the VSP and ensure no SDC **errors** are raised, but **warnings** +6. Validate the VSP and ensure no SDC **errors** are raised, but **warnings** are acceptable. If errors are reported, then halt the test and report a failure. -6. Assign the generic VLM to the VSP in SDC. +7. Assign the generic VLM to the VSP in SDC. -7. Create the Virtual Function (VF) in SD. The VF will be +8. Create the Virtual Function (VF) in SD. The VF will be auto-assigned a unique name to avoid collisions with other VSPs in the lab environment. -8. Create the Service in SDC. The Service will be +9. Create the Service in SDC. The Service will be auto-assigned a unique name to avoid collisions with other VSPs in the lab environment. -9. Assign the VF/VNF to the Service Model in SDC. +10. Assign the VF/VNF to the Service Model in SDC. -10. Distribute the Service Model from SDC. +11. Distribute the Service Model from SDC. -11. Register Preload (i.e. per instance configuration data) with SDNC +12. Register Preload (i.e. per instance configuration data) with SDNC -12. For each VF module in the VNF, starting with the base module, trigger +13. For each VF module in the VNF, starting with the base module, trigger instantiation from VID. +14. After VNF Instantiation, query openstack for heat stack details to + validate successful instantiation. + **Pass/Fail Criteria** Following, or during, test execution the tests below will be executed to evaluate the success of the overall test case. As previously stated above, if -any individual test step fails, then the test case will fail. In this scenario, -some or all of the criteria below may not be executed. +any individual test step fails, then the test case will fail. 1. The Heat stack has been successfully created in OpenStack without errors -2. If the VNF exposes Operations, Administration, and Management (OAM) - interfaces on an OAM network, then each IP address address exposed by the - VNF on the OAM network must respond to a PING command. The identification - of the OAM network and IPs is left to the implementation and documentation - of the **Test Engine**. -3. Each virtual machine in the OpenStack Heat stack must have a corresponding - ``vserver`` ONAP's Available and Active Inventory (AAI) component with all - required data elements -4. The VNF has a ``VNFC`` object recorded in AAI with all required data elements + +2. The Heat stack configuration matches the definition from the associated + Heat templates and environment settings provided as input (or derived by) + the **Test Engine** Test Case Description: VNF Onboarding and Instantiation using TOSCA @@ -231,4 +231,4 @@ written in TOSCA and packaged in a CSAR. .. note:: Additional definition of the TOSCA-based flow is required, and will be - provided at a later date.
\ No newline at end of file + provided at a later date. |