1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
|
.. Licensed under a Creative Commons Attribution 4.0 International License.
.. http://creativecommons.org/licenses/by/4.0
.. Copyright 2017 AT&T Intellectual Property. All rights reserved.
.. _ONAP Heat VNF Modularity:
ONAP Heat VNF Modularity
---------------------------
ONAP supports a modular Heat Orchestration Template design pattern,
referred to as *VNF Modularity.* With this approach, a single VNF **MAY** be
composed from one or more Heat Orchestration Templates, each of which
represents a subset of the overall VNF. These component parts are
referred to as *VNF Modules*. During orchestration, these modules
are deployed incrementally to create the complete VNF.
As stated in :need:`R-33132`, a VNF's Heat Orchestration Template **MAY** be
1. Base Module Heat Orchestration Template (also referred to as a
Base Module),
2. Incremental Module Heat Orchestration Template (referred to as
an Incremental Module), or
3. a Cinder Volume Module Heat Orchestration Template (referred to as
Cinder Volume Module).
As stated in :need:`R-20974`, at orchestration time, the VNF's Base Module **MUST**
be deployed first, prior to any incremental modules.
As stated in :need:`R-28980`, :need:`R-86926`, and :need:`R-91497`, a
VNF's incremental module **MAY** be used for
* initial VNF deployment only
* scale out only
* both deployment and scale out
As stated in :need:`R-68122`, a VNF's incremental module **MAY** be deployed
more than once, either during initial VNF deployment and/or scale out
As stated in :need:`R-37028` and :need:`R-13196`, a VNF **MUST** be composed
of one Base Module and *MAY** be composed of zero to many Incremental
Modules.
As stated in :need:`R-20974`, at orchestration time, the VNF's Base Module
**MUST** be deployed first, prior to any incremental modules.
ONAP also supports the concept of an optional, independently deployed
Cinder volume via a separate Heat Orchestration Templates, referred to
as a Cinder Volume Module. This allows the volume to persist after a VM
(i.e., OS::Nova::Server) is deleted, allowing the volume to be reused on
another instance (e.g., during a fail over activity).
The scope of a Cinder volume module, when it exists, must be 1:1 with a
Base module or Incremental Module.
A VNF module (base, incremental, cinder) **MAY** support nested templates.
A shared Heat Resource is a resource that **MAY** be used by
other Heat Resources either in the Base Module or an
Incremental Module.
.. req::
:id: R-61001
:target: VNF
:keyword: MUST
:validation_mode: static
:updated: casablanca
A shared Heat Orchestration Template resource must be defined
in the base module. A shared resource is a resource that that will
be referenced by another resource that is defined in the Base Module
and/or one or more incremental modules. When the shared resource needs
to be referenced by a resource in an incremental module, the UUID of
the shared resource **MUST** be exposed by declaring an ONAP Base
Module Output Parameter.
When the shared resource needs to be referenced by a resource in an
incremental module, the UUID of the shared resource must be exposed by
declaring an ONAP Base Module Output Parameter.
Note that a Cinder volume is not a shared resource. A volume template
must correspond 1:1 with a base module or incremental module.
An example of a shared resource is the resource
OS::Neutron::SecurityGroup. Security groups are sets of IP filter rules
that are applied to a VNF’s networking. The resource OS::Neutron::Port
has a property security_groups which provides the security groups
associated with port. The value of parameter(s) associated with this
property must be the UUIDs of the resource(s)
OS::Neutron::SecurityGroup.
*Note:* A Cinder volume is not considered a shared resource. A volume
template must correspond 1:1 with a base template or add-on module
template.
Suggested Patterns for Modular VNFs
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
There are numerous variations of VNF modularity. Below are two suggested
usage patterns.
**Option 1: Incremental Modules per VNFC type**
a. Base module contains only the shared resources.
b. Group all VMs (e.g., VNFCs) of a given type (i.e. {vm-type}) into its
own incremental module. That is, the VNF has an incremental module
for each {vm-type}.
c. For a given {vm-type} incremental module, the VNF may have
i. One incremental module used for both initial turn up and re-used
for scaling. This approach is used when the number of VMs
instantiated will be the same for initial deployment and scaling.
ii. Two incremental modules, where one is used for initial turn up
and one is used for scaling. This approach is used when the
number of VMs instantiated will be different for initial
deployment and scaling.
**Option 2: Base VNF with Incremental Growth Modules**
a. Base module contains a complete initial VNF instance
b. Incremental modules for incremental scaling units
i. May contain VMs of multiple types in logical scaling combinations
ii. May be separated by VM type for multi-dimensional scaling
With no growth units, Option 2 is equivalent to the "One Heat Template
per VNF" model.
Note that modularization of VNFs is not required. A single Heat
Orchestration Template (a base module) may still define a complete VNF,
which might be appropriate for smaller VNFs that do not have any scaling
options.
Modularity Rules
^^^^^^^^^^^^^^^^^^^
There are some rules to follow when building modular VNF templates:
1. All VNFs must have one Base VNF Module (template) that must be the
first one deployed. The base template:
a. Must include all shared resources (e.g., private networks, server
groups, security groups)
b. Must expose all shared resources (by UUID) as "outputs" in its
associated Heat template (i.e., ONAP Base Module Output
Parameters)
c. May include initial set of VMs
d. May be operational as a stand-alone "minimum" configuration of the
VNF
2. VNFs may have one or more incremental modules which:
a. Defines additional resources that can be added to an existing VNF
b. Must be complete Heat templates
i. i.e. not snippets to be incorporated into some larger template
c. Should define logical growth-units or sub-components of an overall
VNF
d. On creation, receives appropriate Base Module outputs as
parameters
i. Provides access to all shared resources (by UUID)
ii. *VNFs may have one or more incremental modules which must not be
dependent on other Add-On VNF Modules*
e. Multiple instances of an incremental Module may be added to the
same VNF (e.g., incrementally grow a VNF by a fixed "add-on"
growth units)
3. Each VNF Module (base or incremental) may have (optional) an
associated Cinder Volume Module (see Cinder Volumes)
a. Volume modules must correspond 1:1 with a base module or
incremental module
b. A Cinder volume may be embedded within the base module or
incremental module if persistence is not required
4. Shared resource UUIDs are passed between the base module and
incremental modules via Heat Outputs Parameters (i.e., Base Module
Output Parameters)
a. The output parameter name in the base must match the parameter
name in the add-on module
VNF Modularity Examples
^^^^^^^^^^^^^^^^^^^^^^^^^
*Example: Base Module creates SecurityGroup*
A VNF has a base module, named base.yaml, that defines a
OS::Neutron::SecurityGroup. The security group will be referenced by an
OS::Neutron::Port resource in an incremental module, named
INCREMENTAL_MODULE.yaml. The base module defines a parameter in the
outputs:section named dns_sec_grp_id. dns_sec_grp_id is defined as a
parameter in the incremental module. ONAP captures the UUID value of
dns_sec_grp_id from the base module output statement and provides the
value to the incremental module.
Note that the example below is not a complete Heat Orchestration
Template. The {network-role} has been defined as oam to represent an oam
network and the {vm-type} has been defined as dns.
base_MODULE.yaml
.. code-block:: yaml
parameters:
. . .
resources:
DNS_SECURITY_GROUP:
type: OS::Neutron::SecurityGroup
properties:
description: vDNS security group
name:
str_replace:
template: VNF_NAME_sec_grp_DNS
params:
VMF_NAME: {get_param: vnf_name}
rules: [. . . . .
]
. . .
outputs:
dns_sec_grp_id:
description: UUID of DNS Resource SecurityGroup
value: { get_resource: DNS_SECURITY_GROUP }
INCREMENTAL_MODULE.yaml
.. code-block:: yaml
parameters:
dns_sec_grp_id:
type: string
description: security group UUID
. . .
resources:
dns_0_oam_0_port:
type: OS::Neutron::Port
properties:
name:
str_replace:
template: VNF_NAME_dns_oam_port
params:
VNF_NAME: {get_param: vnf_name}
network: { get_param: oam_net_name }
fixed_ips: [{ "ip_address": { get_param: dns_oam_ip_0 }}]
security_groups: [{ get_param: dns_sec_grp_id }]
*Examples: Base Module creates an internal network*
A VNF has a base module, named base_module.yaml, that creates an
internal network. An incremental module, named incremental_module.yaml,
will create a VM that will connect to the internal network. The base
module defines a parameter in the out section named int_oam_net_id.
int_oam_net_id is defined as a parameter in the incremental module.
ONAP captures the UUID value of int_oam_net_id from the base module
output statement and provides the value to the incremental module.
Note that the example below is not a complete Heat Orchestration
Template. The {network-role} has been defined as oam to represent an oam
network and the {vm-type} has been defined as lb for load balancer.
base.yaml
.. code-block:: yaml
heat_template_version: 2013-05-23
resources:
int_oam_network:
type: OS::Neutron::Network
properties:
name: {… }
. . .
outputs:
int_oam_net_id:
value: {get_resource: int_oam_network }
incremental.yaml
.. code-block:: yaml
heat_template_version: 2013-05-23
parameters:
int_oam_net_id:
type: string
description: ID of shared private network from Base template
lb_name_0:
type: string
description: name for the add-on VM instance
resources:
lb_server_0:
type: OS::Nova::Server
properties:
name: {get_param: lb_name_0}
networks:
- port: { get_resource: get_resource: lb_0_int_oam_port_0 }
. . .
lb_0_int_oam_port_0:
type: OS::Neutron::Port
properties:
network: { get_param: int_oam_net_id }
...
|