diff options
author | weinstock, alan <aw2574@att.com> | 2019-02-14 15:30:14 +0000 |
---|---|---|
committer | weinstock, alan <aw2574@att.com> | 2019-02-14 15:30:14 +0000 |
commit | b76c884a5f782d77cc59d46979039dffc9f44952 (patch) | |
tree | 2e1fb10ae931bb55b5937412f4a17d36442be690 /docs/Chapter5/Heat | |
parent | c2a92f88a7c68f14a4e40d23ded1233c20988b49 (diff) |
[VNFRQTS] Removed Reqs 88540, 20947, 54458, 64197
Change-Id: I44878a072163596d7d163a23a15059c4524c4168
Issue-ID: VNFRQTS-555
Signed-off-by: weinstock, alan <aw2574@att.com>
Diffstat (limited to 'docs/Chapter5/Heat')
-rw-r--r-- | docs/Chapter5/Heat/ONAP Heat Resource ID and Parameter Naming Convention/Resource IDs.rst | 95 |
1 files changed, 2 insertions, 93 deletions
diff --git a/docs/Chapter5/Heat/ONAP Heat Resource ID and Parameter Naming Convention/Resource IDs.rst b/docs/Chapter5/Heat/ONAP Heat Resource ID and Parameter Naming Convention/Resource IDs.rst index d7e9b68..69fa19d 100644 --- a/docs/Chapter5/Heat/ONAP Heat Resource ID and Parameter Naming Convention/Resource IDs.rst +++ b/docs/Chapter5/Heat/ONAP Heat Resource ID and Parameter Naming Convention/Resource IDs.rst @@ -260,29 +260,9 @@ OS::Heat::MultipartMime OS::Heat::ResourceGroup ~~~~~~~~~~~~~~~~~~~~~~~~ -There is only a mandatory naming convention for a 'OS::Heat::ResourceGroup' -that is creating sub-interfaces. +There is no mandatory naming convention for +the resource 'OS::Heat::ResourceGroup'. -.. req:: - :id: R-64197 - :target: VNF - :keyword: MUST - :validation_mode: static - :updated: casablanca - - A VNF's Heat Orchestration Template's Resource ``OS::Heat::ResourceGroup`` - Resource ID that creates sub-interfaces **MUST** use the naming convention - - * ``{vm-type}_{vm-type_index}_subint_{network-role}_port_{port-index}_subinterfaces`` - - where - - * ``{vm-type}`` is the vm-type - * ``{vm-type_index}`` is the instance of the ``{vm-type}`` - * ``{network-role}`` is the network-role of the networks - that the sub-interfaces attach to - * ``{port-index}`` is the instance of the port on the vm-type - attached to the network of ``{network-role}`` OS::Heat::SoftwareConfig ~~~~~~~~~~~~~~~~~~~~~~~~ @@ -738,56 +718,6 @@ OS::ContrailV2::InstanceIp * ``v6_IP`` signifies that an IPv6 address is being configured * ``{index}`` is the index of the IPv6 address -.. req:: - :id: R-20947 - :target: VNF - :keyword: MUST - :validation_mode: static - :updated: casablanca - - A VNF's Heat Orchestration Template's Resource ``OS::ContrailV2::InstanceIp`` - that is configuring an IPv4 Address on a sub-interface port attached to a - sub-interface network Resource ID **MUST** use the naming convention - - * ``{vm-type}_{vm-type_index}_subint_{network-role}_vmi_{vmi_index}_IP_{index}`` - - where - - * ``{vm-type}`` is the vm-type - * ``{vm-type_index}`` is the instance of the ``{vm-type}`` - * ``{network-role}`` is the network-role of the network - that the port is attached to - * ``{vmi_index}`` is the instance of the virtual machine interface - (e.g., port) on the vm-type - attached to the network of ``{network-role}`` - * ``IP`` signifies that an IPv4 address is being configured - * ``{index}`` is the index of the IPv4 address - -.. req:: - :id: R-88540 - :target: VNF - :keyword: MUST - :validation_mode: static - :updated: casablanca - - A VNF's Heat Orchestration Template's Resource ``OS::ContrailV2::InstanceIp`` - that is configuring an IPv6 Address on a sub-interface port attached to a - sub-interface network Resource ID **MUST** - use the naming convention - - * ``{vm-type}_{vm-type_index}_subint_{network-role}_vmi_{vmi_index}_v6_IP_{index}`` - - where - - * ``{vm-type}`` is the vm-type - * ``{vm-type_index}`` is the instance of the ``{vm-type}`` - * ``{network-role}`` is the network-role of the network - that the port is attached to - * ``{vmi_index}`` is the instance of the virtual machine interface - (e.g., port) on the vm-type - attached to the network of ``{network-role}`` - * ``v6_IP`` signifies that an IPv6 address is being configured - * ``{index}`` is the index of the IPv6 address OS::ContrailV2::InterfaceRouteTable ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ @@ -995,27 +925,6 @@ OS::ContrailV2::VirtualMachineInterface * ``{vmi_index}`` is the instance of the vmi on the vm-type attached to the network of ``{network-role}`` -.. req:: - :id: R-54458 - :target: VNF - :keyword: MUST - :validation_mode: static - :updated: casablanca - - A VNF's Heat Orchestration Template's Resource - ``OS::ContrailV2::VirtualMachineInterface`` that is attaching to a sub-interface - network Resource ID **MUST** use the naming convention - - * ``{vm-type}_{vm-type_index}_subint_{network-role}_vmi_{vmi_index}`` - - where - - * ``{vm-type}`` is the vm-type - * ``{vm-type_index}`` is the instance of the ``{vm-type}`` - * ``{network-role}`` is the network-role of the network - that the port (i.e. virtual machine interface) is attached to - * ``{vmi_index}`` is the instance of the vmi on the vm-type - attached to the network of ``{network-role}`` OS::ContrailV2::VirtualNetwork ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |