aboutsummaryrefslogtreecommitdiffstats
path: root/common/src/main
diff options
context:
space:
mode:
authorSeshu Kumar M <seshu.kumar.m@huawei.com>2018-03-13 05:16:10 +0000
committerGerrit Code Review <gerrit@onap.org>2018-03-13 05:16:10 +0000
commitd3492feb79c837ed3c33381bc37116d6ebae84a9 (patch)
treeb84df9a7137ff00948403db783c9b1314f60f08e /common/src/main
parent126fe91825f43654be9980aac0c49b612bd39f50 (diff)
parent68ace08f563945edc217b4b6cf5f7067e7b83452 (diff)
Merge "Remove trailing spaces from property files"
Diffstat (limited to 'common/src/main')
-rw-r--r--common/src/main/resources/ASDC.properties52
-rw-r--r--common/src/main/resources/ApiHandler.properties40
-rw-r--r--common/src/main/resources/BPMN.properties8
-rw-r--r--common/src/main/resources/GenericMessages.properties28
-rw-r--r--common/src/main/resources/ResourceAdapter.properties140
5 files changed, 134 insertions, 134 deletions
diff --git a/common/src/main/resources/ASDC.properties b/common/src/main/resources/ASDC.properties
index 4f3864dac2..5f4f0baa6c 100644
--- a/common/src/main/resources/ASDC.properties
+++ b/common/src/main/resources/ASDC.properties
@@ -51,7 +51,7 @@ ASDC_GENERAL_WARNING=\
MSO-ASDC-5301W|\
WARNING: {0}|\
Please check other logs for more detailed info|\
- General warning
+ General warning
ASDC_AUDIT_EXEC=\
MSO-ASDC-5302I|\
Executing method: {0}. {1}|\
@@ -61,77 +61,77 @@ ASDC_GENERAL_METRICS=\
MSO-ASDC-5305I|\
Executed method: {0}. {1}|\
No resolution needed|\
- Generate information for Metric events
+ Generate information for Metric events
ASDC_CREATE_SERVICE=\
MSO-ASDC-5306I|\
Creating new VNF Resource for service {0} with id {1} and version {2}|\
No resolution needed|\
- Method triggered to create new VNF Resource
+ Method triggered to create new VNF Resource
ASDC_CREATE_ARTIFACT=\
MSO-ASDC-5307I|\
Installing new {0} for service {1} with id {2} and version {3}|\
No resolution needed|\
- Method triggered to create new VNF Resource
+ Method triggered to create new VNF Resource
ASDC_ARTIFACT_ALREADY_DEPLOYED=\
MSO-ASDC-5308W|\
Constraint violation caught, artifact is already deployed {0} and version {1}|\
No resolution needed|\
- Artifact is already deployed
+ Artifact is already deployed
ASDC_ARTIFACT_INSTALL_EXC=\
MSO-ASDC-5309E|\
Exception caught during installation of the {0}. Transaction rollback.|\
Please check other logs for more detailed info|\
- Exception caught during installation of the artifact
+ Exception caught during installation of the artifact
ASDC_CHECK_HEAT_TEMPLATE=\
MSO-ASDC-5310I|\
Start to verify whether {0} with name {1} and version {2} is already deployed|\
No resolution needed|\
- Check artifact
+ Check artifact
ASDC_ARTIFACT_ALREADY_DEPLOYED_DETAIL=\
MSO-ASDC-5311I|\
ResourceInstanceName:{0} (ResourceUUID:{1}) is already deployed for this Service:{2}/{3}(ServiceUUID:{4}) (ResourceName: {5})|\
No resolution needed|\
- Resource is already deployed
+ Resource is already deployed
ASDC_ARTIFACT_NOT_DEPLOYED_DETAIL=\
MSO-ASDC-5312I|\
ResourceInstanceName:{0} (ResourceUUID:{1}) is not yet deployed for this Service:{2}/{3}(ServiceUUID:{4}) (ResourceName: {5})|\
No resolution needed|\
- Resource is not yet deployed
+ Resource is not yet deployed
ASDC_INIT_ASDC_CLIENT_EXC=\
MSO-ASDC-5314W|\
ASDControllerException caught during the Init/closing of ASDC Client with address {0} and environment {1}|\
Please check other logs for more detailed info|\
- ASDControllerException caught during the Init/closing of ASDC Client
+ ASDControllerException caught during the Init/closing of ASDC Client
ASDC_LOAD_ASDC_CLIENT_EXC=\
MSO-ASDC-5315W|\
ASDCParametersException caught during loading/reloading of the ASDC Client with address {0} and environment {1}|\
Please check other logs for more detailed info|\
- ASDCParametersException caught during loading/reloading of the ASDC Client
+ ASDCParametersException caught during loading/reloading of the ASDC Client
ASDC_SHUTDOWN_ASDC_CLIENT_EXC=\
MSO-ASDC-5317W|\
{0} caught during the ASDC Controller with address {1} and environment {2} shutdown|\
Please check other logs for more detailed info|\
- Exception caught during the ASDC Controller shutdown
+ Exception caught during the ASDC Controller shutdown
ASDC_START_INSTALL_ARTIFACT=\
MSO-ASDC-5318I|\
Trying to install the artifact:{0}|\
No resolution needed|\
- Trying to install the artifact
+ Trying to install the artifact
ASDC_ARTIFACT_TYPE_NOT_SUPPORT=\
MSO-ASDC-5319W|\
This artifact type is not supported:{0}|\
No resolution needed|\
- Artifact type is not supported
+ Artifact type is not supported
ASDC_ARTIFACT_ALREADY_EXIST=\
MSO-ASDC-5320I|\
No need to download the artifact as it exists already in MSO:{0} (UUID:{1}) associated to ResourceName {2}|\
No resolution needed|\
- Artifact already exists
+ Artifact already exists
ASDC_ARTIFACT_DOWNLOAD_SUC=\
MSO-ASDC-5321I|\
Artifact successfully downloaded:{0} (UUID:{1}) (SIZE in Bytes:{2})|\
No resolution needed|\
- Artifact successfully downloaded
+ Artifact successfully downloaded
ASDC_ARTIFACT_DOWNLOAD_FAIL=\
MSO-ASDC-5322E|\
Artifact :{0} could not be downloaded correctly from ASDC URL {1} (UUID:{2}) Error message is {3})|\
@@ -141,47 +141,47 @@ ASDC_START_DEPLOY_ARTIFACT=\
MSO-ASDC-5323I|\
Trying to deploy the artifact:{0} (UUID:{1})|\
No resolution needed|\
- Trying to deploy the artifact
+ Trying to deploy the artifact
ASDC_ARTIFACT_DEPLOY_SUC=\
MSO-ASDC-5324I|\
Resource successfully installed:{0} (UUID:{1}) (Nb of Modules:{2})|\
No resolution needed|\
- Resource successfully installed
+ Resource successfully installed
ASDC_SEND_NOTIF_ASDC=\
MSO-ASDC-5325I|\
Sending {0} ({1}) notification to ASDC for artifact:{2}|\
No resolution needed|\
- Sending notif to ASDC
+ Sending notif to ASDC
ASDC_SEND_NOTIF_ASDC_EXEC=\
MSO-ASDC-5326W|\
Exception caught when trying to notify ASDC|\
Please check other logs for more detailed info|\
- Exception caught when trying to notify ASDC
+ Exception caught when trying to notify ASDC
ASDC_RECEIVE_CALLBACK_NOTIF=\
MSO-ASDC-5327I|\
Receive a callback notification in ASDC, nb of artifacts: {0} (ServiceUUID:{1})|\
No resolution needed|\
- Receive a callback notification in ASDC
+ Receive a callback notification in ASDC
ASDC_RECEIVE_SERVICE_NOTIF=\
MSO-ASDC-5328I|\
Notification is ServiceVNF, (ServiceUUID:{0})|\
No resolution needed|\
- Receive a callback notification for ServiceVNF
+ Receive a callback notification for ServiceVNF
ASDC_ARTIFACT_NULL=\
MSO-ASDC-5329I|\
Nothing to deploy artifact is NULL, (ServiceUUID:{0})|\
No resolution needed|\
- Nothing to deploy artifact is NULL
+ Nothing to deploy artifact is NULL
ASDC_SERVICE_NOT_SUPPORT=\
MSO-ASDC-5330W|\
Notification received, (ServiceUUID:{0}) is not a ServiceVNF and is therefore skipped|\
No resolution needed|\
- Service not support
+ Service not support
ASDC_INIT_ASDC_CLIENT_SUC=\
MSO-ASDC-5331I|\
ASDC Controller successfully initialized|\
No resolution needed|\
- ASDC client initialized
+ ASDC client initialized
ASDC_GENERAL_EXCEPTION_ARG=\
MSO-ASDC-9300E|\
Exception: {0}|\
@@ -212,4 +212,4 @@ ASDC_GENERAL_INFO=\
MSO-ASDC-9305I|\
INFO: {0}|\
No resolution needed|\
- General Info
+ General Info
diff --git a/common/src/main/resources/ApiHandler.properties b/common/src/main/resources/ApiHandler.properties
index 82d452ae4e..60ecf94655 100644
--- a/common/src/main/resources/ApiHandler.properties
+++ b/common/src/main/resources/ApiHandler.properties
@@ -81,12 +81,12 @@ APIH_DB_UPDATE_EXC=\
MSO-APIH-3008E|\
Unable to update record to DB: {0}|\
Please check other logs for more detailed info|\
- Unable to insert record to DB
+ Unable to insert record to DB
APIH_VALIDATION_ERROR=\
MSO-APIH-4000E|\
Validation failed|\
Please check other logs for more detailed info|\
- Validation failed
+ Validation failed
APIH_REQUEST_VALIDATION_ERROR=\
MSO-APIH-4001E|\
Validation of the input request failed, for incoming request:{0}|\
@@ -96,17 +96,17 @@ APIH_SERVICE_VALIDATION_ERROR=\
MSO-APIH-4002E|\
Service params failed schema validation|\
Please check other logs for more detailed info|\
- Service params failed schema validation
+ Service params failed schema validation
APIH_REQUEST_VALIDATION_ERROR_REASON=\
MSO-APIH-4003E|\
Validation of the input request failed:{0}|\
Please verify the input request|\
- Validation of the input request failed
+ Validation of the input request failed
APIH_VNFREQUEST_VALIDATION_ERROR=\
MSO-APIH-4004E|\
Validation of the VNF Request failed|\
Please verify the VNF Request|\
- Validation of the VNF Request failed
+ Validation of the VNF Request failed
APIH_QUERY_PARAM_WRONG=\
MSO-APIH-5003W|\
Bad Request: {0}|\
@@ -116,7 +116,7 @@ APIH_GENERAL_WARNING=\
MSO-APIH-5004W|\
WARNING: {0}|\
Please check other logs for more detailed info|\
- General warning
+ General warning
APIH_AUDIT_EXEC=\
MSO-APIH-5005I|\
Executing request: {0}. {1}|\
@@ -126,32 +126,32 @@ APIH_GENERAL_METRICS=\
MSO-APIH-5008I|\
Executed method: {0}. {1}|\
No resolution needed|\
- Generate information for Metric events
+ Generate information for Metric events
APIH_REQUEST_NULL=\
MSO-APIH-5009W|\
The request received by MSO is null|\
Please check other logs for more detailed info|\
- The request received by MSO is null
+ The request received by MSO is null
APIH_DUPLICATE_FOUND=\
MSO-APIH-5011W|\
Duplicated request found: {0}|\
Please check other logs for more detailed info|\
- Duplicated request found
+ Duplicated request found
APIH_BAD_ORDER=\
MSO-APIH-5012W|\
Request received with wrong order: {0}|\
Please check other logs for more detailed info|\
- Request received with wrong order
+ Request received with wrong order
APIH_BPEL_RESPONSE_ERROR=\
MSO-APIH-5014E|\
Abnormal response received from BPEL server: {0}|\
Please check other logs for more detailed info|\
- Abnormal response received from BPEL server
+ Abnormal response received from BPEL server
APIH_WARP_REQUEST=\
MSO-APIH-5015E|\
Error wrapping request|\
Please check other logs for more detailed info|\
- Error wrapping request to be sent to BPEL server
+ Error wrapping request to be sent to BPEL server
APIH_ERROR_FROM_BPEL_SERVER=\
MSO-APIH-5016E|\
Error from {0} with status:{1} and responseBody:{2}|\
@@ -161,12 +161,12 @@ APIH_CANNOT_READ_SCHEMA=\
MSO-APIH-5017E|\
MSO Configuration Error - Unable to read the schema file|\
Please check other logs for more detailed info|\
- MSO Configuration Error - Unable to read the schema file
+ MSO Configuration Error - Unable to read the schema file
APIH_PROPERTY_LOAD_SUC=\
MSO-APIH-5018I|\
Properties file loaded successfully|\
No resolution needed|\
- Properties file loaded successfully
+ Properties file loaded successfully
APIH_NO_PROPERTIES=\
MSO-APIH-5019E|\
Missing or invalid properties file: {0}|\
@@ -201,7 +201,7 @@ APIH_GENERAL_EXCEPTION=\
MSO-APIH-9001E|\
Exception encountered|\
Please check other logs for more detailed info|\
- Exception encountered
+ Exception encountered
APIH_HEALTH_CHECK_EXCEPTION=\
MSO-APIH-9002E|\
Exception during health check|\
@@ -221,27 +221,27 @@ APIH_BPEL_COMMUNICATE_ERROR=\
MSO-APIH-9005E|\
Exception during BPEL POST|\
Please check other logs for more detailed info|\
- Exception during BPEL POST
+ Exception during BPEL POST
APIH_SDNC_COMMUNICATE_ERROR=\
MSO-APIH-9006E|\
Exception when sending HTTP POST request to SDNC Adapter|\
Please check other logs for more detailed info|\
- Exception when sending HTTP POST request to SDNC Adapter
+ Exception when sending HTTP POST request to SDNC Adapter
APIH_SDNC_RESPONSE_ERROR=\
MSO-APIH-9007E|\
IOException getting SDNC Adapter response body|\
Please check other logs for more detailed info|\
- IOException getting SDNC Adapter response body
+ IOException getting SDNC Adapter response body
APIH_JAXB_MARSH_ERROR=\
MSO-APIH-9008E|\
Exception when translating query results into string with Jaxb|\
Please check other logs for more detailed info|\
- Exception when translating query results into string with Jaxb
+ Exception when translating query results into string with Jaxb
APIH_JAXB_UNMARSH_ERROR=\
MSO-APIH-9009E|\
Exception when formatting for VNF outputs with Jaxb|\
Please check other logs for more detailed info|\
- Exception when formatting for VNF outputs
+ Exception when formatting for VNF outputs
APIH_DOM2STR_ERROR=\
MSO-APIH-9010E|\
Error converting xml Document to String|\
diff --git a/common/src/main/resources/BPMN.properties b/common/src/main/resources/BPMN.properties
index 9e8a7e7189..848135e716 100644
--- a/common/src/main/resources/BPMN.properties
+++ b/common/src/main/resources/BPMN.properties
@@ -51,12 +51,12 @@ BPMN_GENERAL_INFO=\
MSO-BPEL-5100I|\
INFO: {0}|\
No resolution needed|\
- General info
+ General info
BPMN_GENERAL_WARNING=\
MSO-BPEL-5101W|\
WARNING: {0}|\
Please check other logs for more information|\
- General warning
+ General warning
BPMN_AUDIT_EXEC=\
MSO-BPEL-5102I|\
Executing method: {0}. {1}|\
@@ -76,7 +76,7 @@ BPMN_VARIABLE_NULL=\
MSO-BPEL-5107W|\
Variable {0} is null; skipped|\
No resolution needed|\
- Variable is null
+ Variable is null
BPMN_GENERAL_EXCEPTION_ARG=\
MSO-BPEL-9100E|\
Exception: {0}|\
@@ -86,7 +86,7 @@ BPMN_GENERAL_EXCEPTION=\
MSO-BPEL-9101E|\
Exception encountered|\
Please check other logs for more information|\
- Exception encountered
+ Exception encountered
BPMN_CALLBACK_EXCEPTION=\
MSO-BPEL-9102E|\
{0} Exception occurred processing callback to BPMN process {1}|\
diff --git a/common/src/main/resources/GenericMessages.properties b/common/src/main/resources/GenericMessages.properties
index 26403235c9..a9aa13f61a 100644
--- a/common/src/main/resources/GenericMessages.properties
+++ b/common/src/main/resources/GenericMessages.properties
@@ -51,52 +51,52 @@ GENERAL_WARNING=\
MSO-GENERAL-5401W|\
WARNING: {0}|\
Please check other logs for more detailed info|\
- General warning
+ General warning
AUDIT_EXEC=\
MSO-GENERAL-5402I|\
Executing method: {0}. {1}|\
No resolution needed|\
- Executing method
+ Executing method
GENERAL_METRICS=\
MSO-GENERAL-5405I|\
Executed method: {0}. {1}|\
No resolution needed|\
- Generate information for Metric events
+ Generate information for Metric events
LOGGER_SETUP=\
MSO-GENERAL-5406I|\
Request received to update logger level|\
No resolution needed|\
- Request received to update logger level
+ Request received to update logger level
LOGGER_NOT_FOUND=\
MSO-GENERAL-5407I|\
Logger Servlet: Logger not found: : {0}|\
No resolution needed|\
- Logger not found
+ Logger not found
LOGGER_UPDATE_SUC=\
MSO-GENERAL-5408I|\
Successfully update Logger: {0} from level {1} to level {2}|\
No resolution needed|\
- Generate information for Metric events
+ Generate information for Metric events
LOGGER_UPDATE_DEBUG=\
MSO-GENERAL-5409I|\
Request received to update debug mode|\
No resolution needed|\
- Request received to update debug mode
+ Request received to update debug mode
LOGGER_UPDATE_DEBUG_SUC=\
MSO-GENERAL-5410I|\
Successfully {0} debug mode|\
No resolution needed|\
- Successfully updated debug mode
+ Successfully updated debug mode
LOAD_PROPERTIES_SUC=\
MSO-GENERAL-5411I|\
Properties file loaded successfully from file {0}|\
No resolution needed|\
- Properties file loaded successfully
+ Properties file loaded successfully
NO_PROPERTIES=\
MSO-GENERAL-5412E|\
Missing or invalid properties file: {0}|\
Please verify whether properties file exist or readable|\
- Missing or invalid properties file
+ Missing or invalid properties file
LOAD_PROPERTIES_FAIL=\
MSO-GENERAL-5413E|\
Failed loading properties file: {0}|\
@@ -106,17 +106,17 @@ INIT_LOGGER=\
MSO-GENERAL-5414I|\
Prepare to initialize loggers from {0}|\
No resolution needed|\
- Prepare to initialize loggers
+ Prepare to initialize loggers
MADATORY_PARAM_MISSING=\
MSO-GENERAL-5415E|\
Not able to get mandatory parameter: {0} from file {1}|\
No resolution needed|\
- Mandatory parameter missing
+ Mandatory parameter missing
IDENTITY_SERVICE_NOT_FOUND=\
MSO-GENERAL-5416E|\
Identity service not found: region={0} ,cloud={1}|\
Please check other logs for more detailed info|\
- Identity service not found
+ Identity service not found
GENERAL_EXCEPTION_ARG=\
MSO-GENERAL-9400E|\
Exception: {0}|\
@@ -126,7 +126,7 @@ GENERAL_EXCEPTION=\
MSO-GENERAL-9401E|\
Exception encountered|\
Please check other logs for more detailed info|\
- Exception encountered
+ Exception encountered
INIT_LOGGER_FAIL=\
MSO-GENERAL-9402E|\
Failed to initialize loggers|\
diff --git a/common/src/main/resources/ResourceAdapter.properties b/common/src/main/resources/ResourceAdapter.properties
index 0dbbb3c936..8eed3857d7 100644
--- a/common/src/main/resources/ResourceAdapter.properties
+++ b/common/src/main/resources/ResourceAdapter.properties
@@ -56,42 +56,42 @@ RA_DELETE_STACK_TIMEOUT=\
MSO-RA-2201E|\
Delete Stack - Polling timeout exceeded. cloud={0}, tenant={1}, stack={2}, status={3}|\
Please check other logs for more detailed info|\
- Delete Stack timeout
+ Delete Stack timeout
RA_UPDATE_STACK_TIMEOUT=\
MSO-RA-2202E|\
Update Stack - Polling timeout exceeded. cloud={0}, tenant={1}, stack={2}, status={3}|\
Please check other logs for more detailed info|\
- Delete Stack timeout
+ Delete Stack timeout
RA_MISSING_PARAM=\
MSO-RA-4200I|\
Missing Required parameter: {0}|\
No resolution needed|\
- Mandatory Parameter Missing
+ Mandatory Parameter Missing
RA_PARSING_ERROR=\
MSO-RA-4201E|\
Error parsing file {0}|\
No resolution needed|\
- Error parsing file
+ Error parsing file
RA_MARSHING_ERROR=\
MSO-RA-4202E|\
Error marshalling callback request with JaxB|\
Please check other logs for more detailed info|\
- Error marshalling callback request
+ Error marshalling callback request
RA_PARSING_REQUEST_ERROR=\
MSO-RA-4203E|\
Error parsing request:{0}|\
Please check other logs for more detailed info|\
- Error parsing request
+ Error parsing request
RA_VLAN_PARSE=\
MSO-RA-4204E|\
Error parsing VLAN parameter in network stack {0}:{1}|\
Please check other logs for more detailed info|\
- Error parsing VLAN parameter in network stack
+ Error parsing VLAN parameter in network stack
RA_GENERAL_WARNING=\
MSO-RA-5201W|\
WARNING: {0}|\
Please check other logs for more detailed info|\
- General warning
+ General warning
RA_AUDIT_EXEC=\
MSO-RA-5202I|\
Executing method: {0}. {1}|\
@@ -101,52 +101,52 @@ RA_GENERAL_METRICS=\
MSO-RA-5205I|\
Executed method: {0}. {1}|\
No resolution needed|\
- Generate information for Metric events
+ Generate information for Metric events
RA_PROPERTIES_NOT_FOUND=\
MSO-RA-5206E|\
Properties file: {0} not found|\
Please verify whether properties file exist or readable|\
- Properties file not found
+ Properties file not found
RA_LOAD_PROPERTIES_SUC=\
MSO-RA-5207I|\
Properties file loaded successfully from file {0}|\
No resolution needed|\
- Properties file loaded successfully
+ Properties file loaded successfully
RA_PARAM_NOT_FOUND=\
MSO-RA-5208E|\
Attribute {0} not found in DB. For {1}={2}|\
No resolution needed|\
- Attribute not found in DB
+ Attribute not found in DB
RA_UNKOWN_PARAM=\
MSO-RA-5209E|\
Unknown {0}:{1}|\
Please check other logs for more detailed info|\
- Unknown attribute
+ Unknown attribute
RA_CONFIG_EXC=\
MSO-RA-5210E|\
Configuration error:{0}|\
Please check other logs for more detailed info|\
- Configuration Error
+ Configuration Error
RA_CONFIG_NOT_FOUND=\
MSO-RA-5211E|\
Could not found configuration file:{0}|\
Please verify whether configuration file exist or readable|\
- Configuration file not found
+ Configuration file not found
RA_SEND_REQUEST_SDNC=\
MSO-RA-5212I|\
Sending request to SDNC:{0}|\
No resolution needed|\
- Sending request to SDNC
+ Sending request to SDNC
RA_RESPONSE_FROM_SDNC=\
MSO-RA-5213I|\
Response received from SDNC:{0}|\
No resolution needed|\
- Response received from SDNC
+ Response received from SDNC
RA_CALLBACK_BPEL=\
MSO-RA-5218E|\
Callback to BPEL:{0} |\
Please check other logs for more detailed info|\
- Callback to BPEL
+ Callback to BPEL
RA_NETWORK_ALREADY_EXIST=\
MSO-RA-5240W|\
Network already exists: {0} in {1}/{2}|\
@@ -156,117 +156,117 @@ RA_NETWORK_NOT_FOUND=\
MSO-RA-5241E|\
Network doesn't exist: {0} in {1}/{2}|\
Please check other logs for more detailed info|\
- Network doesn't exist
+ Network doesn't exist
RA_NETWORK_ORCHE_MODE_NOT_SUPPORT=\
MSO-RA-5243E|\
Network Type Orchestrated mode:{0} is not supported|\
Please check other logs for more detailed info|\
- Network Type Orchestrated mode
+ Network Type Orchestrated mode
RA_ROLLBACK_NULL=\
MSO-RA-5249W|\
Rollback: No action to perform|\
No resolution needed|\
- Rollback: No action to perform
+ Rollback: No action to perform
RA_ASYNC_ROLLBACK=\
MSO-RA-5251I|\
Async Rollback Network {0}|\
No resolution needed|\
- Async Rollback Network
+ Async Rollback Network
RA_WSDL_NOT_FOUND=\
MSO-RA-5252E|\
Unable to find wsdl file {0} in classpath|\
No resolution needed|\
- Unable to find wsdl file in classpath
+ Unable to find wsdl file in classpath
RA_CALLBACK_BPEL_COMPLETE=\
MSO-RA-5258I|\
Completed processing BPEL request|\
No resolution needed|\
- Completed processing BPEL request
+ Completed processing BPEL request
RA_SDNC_MISS_CONFIG_PARAM=\
MSO-RA-5259E|\
Missing configuration for:{0}|\
Please check other logs for more detailed info|\
- Missing configuration for
+ Missing configuration for
RA_SDNC_INVALID_CONFIG=\
MSO-RA-5260W|\
Invalid configuration(most requests require atleast 3 params:method,timeout,action) for Key:{0} Value:{1}|\
Please check other logs for more detailed info|\
- Invalid configuration
+ Invalid configuration
RA_TENANT_NOT_FOUND=\
MSO-RA-5263E|\
Tenant not found: tenant={0}, cloudSiteId={1}|\
Please check other logs for more detailed info|\
- Tenant not found
+ Tenant not found
RA_PRINT_URL=\
MSO-RA-5264I|\
{0} URL:{1}|\
No resolution needed|\
- Log the URL
+ Log the URL
RA_RECEIVE_SDNC_NOTIF=\
MSO-RA-5268I|\
Received SDNC Notification. XML:{0}|\
No resolution needed|\
- Received SDNC Notification
+ Received SDNC Notification
RA_INIT_SDNC_ADAPTER=\
MSO-RA-5269I|\
Initializing mso-sdnc-adapter|\
No resolution needed|\
- Initializing mso-sdnc-adapter
+ Initializing mso-sdnc-adapter
RA_RECEIVE_BPEL_REQUEST=\
MSO-RA-5270I|\
BPEL request received [{0}] with callback URL [{1}]|\
No resolution needed|\
- BPEL request received
+ BPEL request received
RA_SEND_REQUEST_SDNC_ERR=\
MSO-RA-5271E|\
Error sending request to SDNC. Failed to start SDNC Client thread|\
Please check other logs for more detailed info|\
- Error sending request to SDNC
+ Error sending request to SDNC
RA_TENANT_ALREADY_EXIST=\
MSO-RA-5272E|\
Tenant {0} already exists in {1}|\
No resolution needed|\
- Tenant alaredy exists
+ Tenant alaredy exists
RA_SEND_REQUEST_APPC_ERR=\
MSO-RA-5273E|\
Error sending request to APPC|\
Please check other logs for more detailed info|\
- Error sending request to APPC
+ Error sending request to APPC
RA_VNF_ALREADY_EXIST=\
MSO-RA-5275E|\
Stack {0} already exists in {1}/{2}|\
No resolution needed|\
- VNF already exists
+ VNF already exists
RA_VNF_UNKNOWN_PARAM=\
MSO-RA-5276E|\
Unknown {0}:{1}|\
No resolution needed|\
- Uknown parameter
+ Uknown parameter
RA_VNF_EXTRA_PARAM=\
MSO-RA-5277E|\
Create Stack ({0}) extra input params received:{1}|\
Please check other logs for more detailed info|\
- Extra input params received
+ Extra input params received
RA_VNF_NOT_EXIST=\
MSO-RA-5278E|\
Stack {0} does not exist in {1}/{2}|\
No resolution needed|\
- Stack does not exist
+ Stack does not exist
RA_ASYNC_CREATE_VNF=\
MSO-RA-5282I|\
Async Create VNF :{0} of type {1} in {2}/{3}|\
No resolution needed|\
- Async Create VNF
+ Async Create VNF
RA_SEND_VNF_NOTIF_ERR=\
MSO-RA-5283E|\
Error sending createVnf notification|\
Please check other logs for more detailed info|\
- Error sending createVnf notification
+ Error sending createVnf notification
RA_ASYNC_CREATE_VNF_COMPLETE=\
MSO-RA-5284I|\
Completed createVnfA|\
No resolution needed|\
- Completed createVnfA
+ Completed createVnfA
RA_ASYNC_UPDATE_VNF=\
MSO-RA-5285I|\
Async Update VNF :{0} of type {1} in {2}/{3}|\
@@ -276,7 +276,7 @@ RA_ASYNC_UPDATE_VNF_COMPLETE=\
MSO-RA-5286I|\
Completed updateVnfA|\
No resolution needed|\
- Completed updateVnfA
+ Completed updateVnfA
RA_ASYNC_QUERY_VNF=\
MSO-RA-5287I|\
Async Query VNF :{0} of type {1} in {2}/{3}|\
@@ -286,7 +286,7 @@ RA_ASYNC_QUERY_VNF_COMPLETE=\
MSO-RA-5288I|\
Completed queryVnfA|\
No resolution needed|\
- Completed queryVnfA
+ Completed queryVnfA
RA_ASYNC_DELETE_VNF=\
MSO-RA-5289I|\
Async Delete VNF :{0} of type {1} in {2}/{3}|\
@@ -296,7 +296,7 @@ RA_ASYNC_DELETE_VNF_COMPLETE=\
MSO-RA-5290I|\
Completed deleteVnfA|\
No resolution needed|\
- Completed deleteVnfA
+ Completed deleteVnfA
RA_ASYNC_ROLLBACK_VNF=\
MSO-RA-5291I|\
Async Rollback VNF|\
@@ -306,7 +306,7 @@ RA_ASYNC_ROLLBACK_VNF_COMPLETE=\
MSO-RA-5292I|\
Completed rollbackVnfA|\
No resolution needed|\
- Completed rollbackVnfA
+ Completed rollbackVnfA
RA_DB_INVALID_STATUS=\
MSO-RA-5293E|\
Invalid status value|\
@@ -316,12 +316,12 @@ RA_DB_REQUEST_NOT_EXIST=\
MSO-RA-5294E|\
Request ID={0} does not exist in DB|\
Please check other logs for more detailed info|\
- Record does not exist in DB
+ Record does not exist in DB
RA_CANT_UPDATE_REQUEST=\
MSO-RA-5295E|\
Enable to update {0} in DB for Request ID={1}|\
Please check other logs for more detailed info|\
- Enable to update DB
+ Enable to update DB
RA_CONFIG_LOAD=\
MSO-RA-5296I|\
Configuration loaded from {0}|\
@@ -331,42 +331,42 @@ RA_RECEIVE_WORKFLOW_MESSAGE=\
MSO-RA-5297I|\
Received Workflow Message: {0}|\
No resolution needed|\
- Received Workflow Message
+ Received Workflow Message
RA_NS_EXC=\
MSO-RA-5298I|\
VFC Adatper Message: {0}|\
No resolution needed|\
- VFC Adatper Message
+ VFC Adatper Message
RA_GENERAL_EXCEPTION_ARG=\
MSO-RA-9200E|\
Exception: {0}|\
Please check other logs for more detailed info|\
- General exception with reason
+ General exception with reason
RA_GENERAL_EXCEPTION=\
MSO-RA-9201E|\
Exception encountered|\
Please check other logs for more detailed info|\
- Exception encountered
+ Exception encountered
RA_CONNECTION_EXCEPTION=\
MSO-RA-9202E|\
Exception communicating with {0}: {1}|\
Please check other logs for more detailed info|\
- Communication Exception
+ Communication Exception
RA_EXCEPTION_COMMUNICATE_SDNC=\
MSO-RA-9203E|\
Exception while processing request to SDNC|\
Please check other logs for more detailed info|\
- Exception while processing request to SDNC
+ Exception while processing request to SDNC
RA_EVALUATE_XPATH_ERROR=\
MSO-RA-9204E|\
Error while evaluating xpath {0} - {1}|\
Please check other logs for more detailed info|\
- Error while evaluating xpath
+ Error while evaluating xpath
RA_ANALYZE_ERROR_EXC=\
MSO-RA-9205E|\
Problem analyzing error returned by SDN-C|\
Please check other logs for more detailed info|\
- Problem analyzing error returned by SDN-C
+ Problem analyzing error returned by SDN-C
RA_ERROR_GET_RESPONSE_SDNC=\
MSO-RA-9206E|\
Error getting response code from errored SDNC request|\
@@ -381,7 +381,7 @@ RA_CREATE_STACK_ERR=\
MSO-RA-9208E|\
Create Stack Error: {0}|\
Please check other logs for more detailed info|\
- Create Stack Error
+ Create Stack Error
RA_UPDATE_STACK_ERR=\
MSO-RA-9209E|\
Update Stack Error - Polling complete with non-success status: {0}, {1}|\
@@ -391,17 +391,17 @@ RA_UPDATE_NETWORK_ERR=\
MSO-RA-9210E|\
Exception while update network, {0} in {1}/{2}|\
Please check other logs for more detailed info |\
- Update Network Error
+ Update Network Error
RA_QUERY_NETWORK_EXC=\
MSO-RA-9211E|\
Exception while query network: {0} in {1}/{2}|\
Please check other logs for more detailed info|\
- Exception while query network:
+ Exception while query network:
RA_CREATE_NETWORK_EXC=\
MSO-RA-9212E|\
Exception while create network: {0} in {1}/{2}|\
Please check other logs for more detailed info|\
- Create Network Error
+ Create Network Error
RA_DELETE_NETWORK_EXC=\
MSO-RA-9213E|\
Exception while delete network: {0} in {1}/{2}|\
@@ -416,12 +416,12 @@ RA_WSDL_URL_CONVENTION_EXC=\
MSO-RA-9215E|\
{0} URL converion failed|\
Please check other logs for more detailed info|\
- WSDL URL converion failed
+ WSDL URL converion failed
RA_INIT_NOTIF_EXC=\
MSO-RA-9216E|\
Caught exception initializing Notification Url|\
Please check other logs for more detailed info|\
- Caught exception initializing Notification Url
+ Caught exception initializing Notification Url
RA_SET_CALLBACK_AUTH_EXC=\
MSO-RA-9217E|\
Unable to set authorization in callback request|\
@@ -431,7 +431,7 @@ RA_FAULT_INFO_EXC=\
MSO-RA-9218E|\
Exception caught while getting fault info|\
Please check other logs for more detailed info|\
- Exception caught while getting fault info
+ Exception caught while getting fault info
RA_CALLBACK_BPEL_EXC=\
MSO-RA-9219E|\
Error sending BPEL Callback request|\
@@ -441,7 +441,7 @@ RA_CREATE_TENANT_ERR=\
MSO-RA-9220E|\
Create Tenant Error: {0}|\
Please check other logs for more detailed info|\
- Create Tenant Error
+ Create Tenant Error
RA_DELETE_TEMAMT_ERR=\
MSO-RA-9221E|\
Delete Tenant Error: {0}|\
@@ -451,12 +451,12 @@ RA_ERROR_CREATE_SDNC_REQUEST=\
MSO-RA-9222E|\
Error creating SDNC request|\
Please check other logs for more detailed info|\
- Error creating SDNC request
+ Error creating SDNC request
RA_ERROR_CREATE_SDNC_RESPONSE=\
MSO-RA-9223E|\
Error creating SDNC response|\
Please check other logs for more detailed info|\
- Error creating SDNC response
+ Error creating SDNC response
RA_ERROR_CONVERT_XML2STR=\
MSO-RA-9224E|\
Error converting xml Document to String|\
@@ -466,12 +466,12 @@ RA_UPDATE_TENANT_ERR=\
MSO-RA-9225E|\
Update Tenant Error: {0}|\
Please check other logs for more detailed info|\
- Update Tenant Error
+ Update Tenant Error
RA_ROLLBACK_TENANT_ERR=\
MSO-RA-9226E|\
Rollback Tenant Error: {0}|\
Please check other logs for more detailed info|\
- Rollback Tenant Error
+ Rollback Tenant Error
RA_QUERY_VNF_ERR=\
MSO-RA-9227E|\
Exception while query VNF:{0} in {1}/{2}|\
@@ -481,12 +481,12 @@ RA_UPDATE_VNF_ERR=\
MSO-RA-9228E|\
Exception while update VNF:{0} in {1}/{2}|\
Please check other logs for more detailed info|\
- Exception while update VNF
+ Exception while update VNF
RA_DELETE_VNF_ERR=\
MSO-RA-9229E|\
Exception while delete VNF:{0} in {1}/{2}|\
Please check other logs for more detailed info|\
- Exception while delete VNF
+ Exception while delete VNF
RA_CREATE_VNF_ERR=\
MSO-RA-9230E|\
Exception while create VNF:{0} in {1}/{2}|\
@@ -496,4 +496,4 @@ RA_ROLLBACK_VNF_ERR=\
MSO-RA-9231E|\
Exception while rollback VNF|\
Please check other logs for more detailed info|\
- Exception while rollback VNF
+ Exception while rollback VNF