aboutsummaryrefslogtreecommitdiffstats
path: root/platform-logic/optical-service/src/main/xml/optical-service_call-bandwidth-update-pinterface.xml
blob: 1a39aa6b4e0db8fd7f39e9f0a1c1a2a5dd628446 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
<service-logic
    xmlns='http://www.onap.org/sdnc/svclogic'
    xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.onap.org/sdnc/svclogic ./svclogic.xsd' module='optical-service' version='${project.version}'>
    <method rpc='call-bandwidth-update-pinterface' mode='sync'>
        <block atomic="true">
            <record plugin="org.onap.ccsdk.sli.core.sli.recording.FileRecorder">
                <parameter name="file" value="/opt/opendaylight/current/data/log/test.log" />
                <parameter name="level" value="info" />
                <parameter name="field1" value="`$div`"/>
            </record>
            <get-resource plugin="org.onap.ccsdk.sli.adaptors.aai.AAIService"
resource="p-interface"
 key="pnf.pnf-name = $pnf-name AND
     p-interface.interface-name = $pinterface-name AND depth = 'all'"
pfx='pin'      local-only='false'></get-resource>
            <switch test='`$pin.network-interface-type`'>
                <outcome value='Other'>
                    <block atomic="true">
                        <record plugin="org.onap.ccsdk.sli.core.sli.recording.FileRecorder">
                            <parameter name="file" value="/opt/opendaylight/current/data/log/service-create-tapi.log" />
                            <parameter name="level" value="info" />
                            <parameter name="field1" value="Port is NNI"/>
                        </record>
                        <call module='optical-service' rpc='bandwidth-update' mode='sync' ></call>
                    </block>
                </outcome>
                <outcome value='UNI'>
                    <block atomic="true">
                        <record plugin="org.onap.ccsdk.sli.core.sli.recording.FileRecorder">
                            <parameter name="file" value="/opt/opendaylight/current/data/log/service-create-tapi.log" />
                            <parameter name="level" value="info" />
                            <parameter name="field1" value="Port is UNI"/>
                        </record>
                        <update plugin='org.onap.ccsdk.sli.adaptors.aai.AAIService' 
force='true'
resource='available-bandwidth'
     key='pnf.pnf-name = $pnf-name AND
     p-interface.interface-name = $pinterface-name' 
      local-only='false'>
                            <parameter name='available-capacity' value='0' />
                        </update>
                    </block>
                </outcome>
            </switch>
        </block>
    </method>
</service-logic>