aboutsummaryrefslogtreecommitdiffstats
path: root/vnfs/vCPE/scripts/v_gmux_install.sh
AgeCommit message (Collapse)AuthorFilesLines
2018-08-07Refactor vCPE vG-MUX and vG image creation processPraneta Paithankar1-283/+68
Separate heat/env templates and build scripts have been created for vG-MUX and vG The build logic and parameters are removed from the install scripts and the base heat/env files used to deploy the VMs. For backwards compatibility, the compile_state parameter was added to both VMs.  Small corrections were made to the heat templates for clarity. Issue-ID: INT-615 Change-Id: I3180654f959776ebd4706613e00b9faff3f72e9e Signed-off-by: Praneta Paithankar <praneta.paithankar@intel.com>
2018-07-19Deprecate use of sites/raw for vnf HEAT templatesGary Wu1-3/+2
Replace the use of sites/raw in vnf HEAT templates with zipped script artifacts Change-Id: I93c331c0f4753e8bf661e5a577463ab38bd116f5 Issue-ID: INT-592 Signed-off-by: Gary Wu <gary.i.wu@huawei.com>
2018-07-12Fix vGMUX building from snapshot dependency issuesEnyinna Ochulor1-4/+4
The vgmux env, yaml, install script, and hc2vpp patch files were edited to remove snapshot dependencies. Change-Id: Ibfdef8cf35013c4fea8254437d12098a0bb82575 Issue-ID: INT-525 Signed-off-by: Enyinna Ochulor <enyinna.ochulor@intel.com>
2017-11-29Reset VES packet loss rate to zero on rebootEric Multanen1-26/+14
Adds logic to reset the VES packet loss rate to 0% when the vg-mux is rebooted. As part of this change, the VES agent configuration will only be restored via the honeycomb persistence mechanism. So, if the VES agent is configured via the vppctl CLI, that setting will not be saved during shutdown. In other words, setting of the VES agent and VES mode should be done via the honeycomb REST API in order for the configuration to be persisted across reboot (with the pkt loss rate being reset to 0 %). Change-Id: I8d1f43316d9608f8d7e7ce919f129ce8fe48aa7f Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-11-06Configure route to vBRG via vBNG on vGMUXEric Multanen1-2/+5
Add parameters to the heat template to allow configuration of the route the vBRG from the vGMUX via the vBNG. Change-Id: I7aef31af7470ceb264af06326af8724246c7d8ed Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-26vCPE vG-MUX- fix auto ugrade disable configurationEric Multanen1-1/+7
Move configuration of disabling auto upgrade to the 'build' phase of the install script. Also, disable the setting in the /etc/apt/apt.conf.d/20auto-upgrades file. Auto upgrade of the kernel without associated packages can cause vpp to stop working. This should help keep the demo instances running without occasional failures. Change-Id: Ief46bc7866a94d67fe2c3d2fe2d1f22bb4433aa9 Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-26vCPE vG-MUX - fixup default vpp configurationEric Multanen1-6/+19
Instead of hard coding VPP interface names, derive them from the PCI addresses of the network devices when setting up the default vpp configuration in /etc/vpp/setup.gate. Also, remove the vxlan tunnel configuration from the default vpp configuration - this will be created by SDNC. Change-Id: Ife48ac19b8d3869c7d65e83bdf8ab9a5a2c3301c Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-24Fixes for the vCPE vG-MUX install scriptEric Multanen1-125/+155
This change improves the vG-MUX install script by: - setting bng-mux network IP and mux-gw IP from environment variables instead of hardcoded values - provides ability to use script to prepare a snapshot image with the vpp and honeycomb binaries pre-compiles to improve vnf deployment time (was taking about 40 minutes). Change-Id: Ib5423af6d88f4501ac3ecfd4a4cbc9b315460194 Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-18Fixup errors in vgmux install scriptEric Multanen1-2/+2
Correct a couple typos made in the vgmux install script. Change-Id: Ib6eff3a875c3588bb1aad42a4105827d883b9c8d Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-17Fixes for vCPE vG-MUX install scriptEric Multanen1-60/+50
Addresses the following items: - Do not setup auto configuration for eth1 and eth3 These interfaces will be used by vpp so they need to be down - Fix pci bus numbering for vpp interfaces - Fixes to properly create the 'save_config' script - Install linux-image-extra package to get uio_pci_generic driver module for the vpp dpdk interfaces - fix build of honeycomb so the jvpp-ves module built by vpp can be found - Patch libevel.so code to tweak the VES data produced so that sourceId and sourceName come from the openstack vnf_id property (instead of vm_uuid and vm_name) Issue-ID: INT-63 Change-Id: I469c2377df9dd9920a5769628b2b14d043d55d63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-10-10Fix patch URLs for vCPE use case and other fixesEric Multanen1-0/+1
Fixup URLs for the patch files to be applied to VPP and honeycomb components. Fix what looked like a typo in vgmux key attribute. Create maven ~/.m2 directory before saving file to it. Change-Id: Iccd10dac44b51a3ad4721422619c8823d8fa65bb Issue-ID: INT-63 Signed-off-by: Eric Multanen <eric.w.multanen@intel.com>
2017-09-22Upgrade VES library from 4.2 to 5.xJohnson Li1-10/+9
Issue-ID: INT-80 Change-Id: I6ae3cabf62c85a8da85c8a4623db4aae0e5e4281 Signed-off-by: Johnson Li <johnson.li@intel.com>
2017-09-14Add patch for BRG and scripts to set the NAT ruleJohnson Li1-1/+470
Add Framework codes for the vCPE VNFs Issue-ID: INT-80 Change-Id: I312aef9631636f0e2273f482f5db44ca93a55983 Signed-off-by: Johnson Li <johnson.li@intel.com> Signed-off-by: root <rujun.li@intel.com>
2017-09-01Add Java repo to all install scriptsMarco Platania1-2/+2
- ONAP install - vCPE/vFW/vLB use cases - Use sources.list.d instead of apt-add-repository - Parametrize the OS name Change-Id: I7287fda8c5f3aa4ecd42ff576ebfd3b937bfa549 Issue-ID: INT-129 Signed-off-by: Marco Platania <platania@research.att.com>
2017-09-01Add the Java repository to vCPE VMsMarco Platania1-2/+3
- Add repos to sources.list.d instead of using add-apt-repository Change-Id: I3f84bce0e189c3c0eed3d3dd2a292761726ec236 Issue-ID: INT-129 Signed-off-by: Marco Platania <platania@research.att.com>
2017-08-11Remove useless commentsMarco Platania1-1/+0
Change-Id: I787ea63999ab302c064f4288ea68bd0de5139d37 Signed-off-by: Marco Platania <platania@research.att.com>
2017-08-10Add vCPE use case install scriptsMarco Platania1-0/+88
Change-Id: I36085089fcb524f9b0526717449feefc1c45f73b Signed-off-by: Marco Platania <platania@research.att.com>