summaryrefslogtreecommitdiffstats
path: root/config_binding_service/logging.py
diff options
context:
space:
mode:
authorTommy Carpenter <tommy@research.att.com>2019-05-29 13:36:01 -0400
committerTommy Carpenter <tommy@research.att.com>2019-06-04 09:12:25 -0400
commite14b49ead38227ff17d760c4771d58d9c6d2e7c0 (patch)
tree9e3cdc16376a5fb5f4b825a3930b28a89f58bccd /config_binding_service/logging.py
parent040d03d77587ce24f0e99ee504b5b0ff5473a39e (diff)
Switch to gevent
Issue-ID: DCAEGEN2-1549 Change-Id: I762d9630f857a23b6ae61992d483cdca7bb6f88d Signed-off-by: Tommy Carpenter <tommy@research.att.com>
Diffstat (limited to 'config_binding_service/logging.py')
-rw-r--r--config_binding_service/logging.py237
1 files changed, 237 insertions, 0 deletions
diff --git a/config_binding_service/logging.py b/config_binding_service/logging.py
new file mode 100644
index 0000000..35750f2
--- /dev/null
+++ b/config_binding_service/logging.py
@@ -0,0 +1,237 @@
+# ============LICENSE_START=======================================================
+# Copyright (c) 2017-2019 AT&T Intellectual Property. All rights reserved.
+# ================================================================================
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+# ============LICENSE_END=========================================================
+#
+# ECOMP is a trademark and service mark of AT&T Intellectual Property.
+
+import logging
+from logging.handlers import RotatingFileHandler
+from os import makedirs
+import datetime
+
+# These loggers will be overwritten with EELF logging when running in Docker
+_AUDIT_LOGGER = logging.getLogger("defaultlogger")
+_ERROR_LOGGER = logging.getLogger("defaultlogger")
+_METRICS_LOGGER = logging.getLogger("defaultlogger")
+
+# Set up debug logger
+DEBUG_LOGGER = logging.getLogger("defaultlogger")
+handler = logging.StreamHandler()
+formatter = logging.Formatter("%(asctime)s [%(name)-12s] %(levelname)-8s %(message)s")
+handler.setFormatter(formatter)
+DEBUG_LOGGER.addHandler(handler)
+DEBUG_LOGGER.setLevel(logging.DEBUG)
+
+
+def _create_logger(name, logfile):
+ """
+ Create a RotatingFileHandler and a streamhandler for stdout
+ https://docs.python.org/3/library/logging.handlers.html
+ what's with the non-pythonic naming in these stdlib methods? Shameful.
+ """
+ logger = logging.getLogger(name)
+ file_handler = RotatingFileHandler(logfile, maxBytes=10000000, backupCount=2) # 10 meg with one backup..
+ formatter = logging.Formatter("%(message)s")
+ file_handler.setFormatter(formatter)
+ logger.setLevel("DEBUG")
+ logger.addHandler(file_handler)
+ return logger
+
+
+# Public
+
+
+def get_module_logger(mod_name):
+ """
+ To use this, do logger = get_module_logger(__name__)
+ """
+ logger = logging.getLogger(mod_name)
+ handler = logging.StreamHandler()
+ formatter = logging.Formatter("%(asctime)s [%(name)-12s] %(levelname)-8s %(message)s")
+ handler.setFormatter(formatter)
+ logger.addHandler(handler)
+ logger.setLevel(logging.DEBUG)
+ return logger
+
+
+def create_loggers():
+ """
+ Public method to set the global logger, launched from Run
+ This is *not* launched during unit testing, so unit tests do not create/write log files
+ """
+ makedirs("/opt/logs", exist_ok=True)
+
+ # create the audit log
+ aud_file = "/opt/logs/audit.log"
+ open(aud_file, "a").close() # this is like "touch"
+ global _AUDIT_LOGGER
+ _AUDIT_LOGGER = _create_logger("config_binding_service_audit", aud_file)
+
+ # create the error log
+ err_file = "/opt/logs/error.log"
+ open(err_file, "a").close() # this is like "touch"
+ global _ERROR_LOGGER
+ _ERROR_LOGGER = _create_logger("config_binding_service_error", err_file)
+
+ # create the metrics log
+ met_file = "/opt/logs/metrics.log"
+ open(met_file, "a").close() # this is like "touch"
+ global _METRICS_LOGGER
+ _METRICS_LOGGER = _create_logger("config_binding_service_metrics", met_file)
+
+
+def utc():
+ """gets current time in utc"""
+ return datetime.datetime.utcnow()
+
+
+def audit(raw_request, bts, xer, rcode, calling_mod, msg="n/a"):
+ """
+ write an EELF audit record per https://wiki.onap.org/download/attachments/1015849/ONAP%20application%20logging%20guidelines.pdf?api=v2
+ %The audit fields implemented:
+
+ 1 BeginTimestamp Implemented (bts)
+ 2 EndTimestamp Auto Injected when this is called
+ 3 RequestID Implemented (xer)
+ 5 threadId n/a
+ 7 serviceName Implemented (from Req)
+ 9 StatusCode Auto injected based on rcode
+ 10 ResponseCode Implemented (rcode)
+ 13 Category log level - all audit records are INFO.
+ 15 Server IP address Implemented (from Req)
+ 16 ElapsedTime Auto Injected (milliseconds)
+ 17 Server This is running in a Docker container so this is not applicable, my HOSTNAME is always "config_binding_service"
+ 18 ClientIPaddress Implemented (from Req)
+ 19 class name Implemented (mod), though docs say OOP, I am using the python module here
+ 20 Unused ...implemented....
+ 21-25 Custom n/a
+ 26 detailMessage Implemented (msg)
+
+ Not implemented
+ 4 serviceInstanceID - ?
+ 6 physical/virtual server name (Optional)
+ 8 PartnerName - nothing in the request tells me this
+ 11 Response Description - the CBS follows standard HTTP error codes so look them up
+ 12 instanceUUID - Optional
+ 14 Severity (Optional)
+ """
+ ets = utc()
+
+ _AUDIT_LOGGER.info(
+ "{bts}|{ets}|{xer}||n/a||{path}||{status}|{rcode}|||INFO||{servip}|{et}|config_binding_service|{clientip}|{calling_mod}|||||||{msg}".format(
+ bts=bts.isoformat(),
+ ets=ets.isoformat(),
+ xer=xer,
+ rcode=rcode,
+ path=raw_request.path.split("/")[1],
+ status="COMPLETE" if rcode < 400 else "ERROR",
+ servip=raw_request.host.split(":")[0],
+ et=int((ets - bts).microseconds / 1000), # supposed to be in milleseconds
+ clientip=raw_request.remote_addr,
+ calling_mod=calling_mod,
+ msg=msg,
+ )
+ )
+
+
+def error(raw_request, xer, severity, ecode, tgt_entity="n/a", tgt_path="n/a", msg="n/a", adv_msg="n/a"):
+ """
+ write an EELF error record per
+ the error fields implemented:
+
+ 1 Timestamp Auto Injected when this is called
+ 2 RequestID Implemented (xer)
+ 3 ThreadID n/a
+ 4 ServiceName Implemented (from Req)
+ 6 TargetEntity Implemented (tgt_entity)
+ 7 TargetServiceName Implemented (tgt_path)/
+ 8 ErrorCategory Implemented (severity)
+ 9. ErrorCode Implemented (ecode)
+ 10 ErrorDescription Implemented (msg)
+ 11. detailMessage Implemented (adv_msg)
+
+ Not implemented:
+ 5 PartnerName - nothing in the request tells me this
+ """
+ ets = utc()
+
+ _ERROR_LOGGER.error(
+ "{ets}|{xer}|n/a|{path}||{tge}|{tgp}|{sev}|{ecode}|{msg}|{amsg}".format(
+ ets=ets,
+ xer=xer,
+ path=raw_request.path.split("/")[1],
+ tge=tgt_entity,
+ tgp=tgt_path,
+ sev=severity,
+ ecode=ecode,
+ msg=msg,
+ amsg=adv_msg,
+ )
+ )
+
+
+def metrics(raw_request, bts, xer, target, target_path, rcode, calling_mod, msg="n/a"):
+ """
+ write an EELF metrics record per https://wiki.onap.org/download/attachments/1015849/ONAP%20application%20logging%20guidelines.pdf?api=v2
+ %The metrics fields implemented:
+
+ 1 BeginTimestamp Implemented (bts)
+ 2 EndTimestamp Auto Injected when this is called
+ 3 RequestID Implemented (xer)
+ 5 threadId n/a
+ 7 serviceName Implemented (from Req)
+ 9 TargetEntity Implemented (target)
+ 10 TargetServiceName Implemented (target_path)
+ 11 StatusCode Implemented (based on rcode)
+ 12 Response Code Implemented (rcode)
+ 15 Category log level all metrics records are INFO.
+ 17 Server IP address Implemented (from Req)
+ 18 ElapsedTime Auto Injected (milliseconds)
+ 19 Server This is running in a Docker container so this is not applicable, my HOSTNAME is always "config_binding_service"
+ 20 ClientIPaddress Implemented (from Req)
+ 21 class name Implemented (mod), though docs say OOP, I am using the python module here
+ 22 Unused ...implemented....
+ 24 TargetVirtualEntity n/a
+ 25-28 Custom n/a
+ 29 detailMessage Implemented (msg)
+
+ Not implemented
+ 4 serviceInstanceID - ?
+ 6 physical/virtual server name (Optional)
+ 8 PartnerName - nothing in the request tells me this
+ 13 Response Description - the CBS follows standard HTTP error codes so look them up
+ 14 instanceUUID - Optional
+ 16 Severity (Optional)
+ 23 ProcessKey - optional
+ """
+ ets = utc()
+
+ _METRICS_LOGGER.info(
+ "{bts}|{ets}|{xer}||n/a||{path}||{tge}|{tgp}|{status}|{rcode}|||INFO||{servip}|{et}|config_binding_service|{clientip}|{calling_mod}|||n/a|||||{msg}".format(
+ bts=bts.isoformat(),
+ ets=ets.isoformat(),
+ xer=xer,
+ path=raw_request.path.split("/")[1],
+ tge=target,
+ tgp=target_path,
+ status="COMPLETE" if rcode < 400 else "ERROR",
+ rcode=rcode,
+ servip=raw_request.host.split(":")[0],
+ et=int((ets - bts).microseconds / 1000), # supposed to be in milleseconds
+ clientip=raw_request.remote_addr,
+ calling_mod=calling_mod,
+ msg=msg,
+ )
+ )