aboutsummaryrefslogtreecommitdiffstats
path: root/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json
diff options
context:
space:
mode:
Diffstat (limited to 'sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json')
-rw-r--r--sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json435
1 files changed, 0 insertions, 435 deletions
diff --git a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json
deleted file mode 100644
index 5c6e41a9d..000000000
--- a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/onf-ptp-dataset.schema-information.json
+++ /dev/null
@@ -1,435 +0,0 @@
-{
- "schema-information": {
- "instance-number": {
- "id": "instance-number",
- "type": "uint16",
- "order-number": 1,
- "is-read-only": true,
- "description": ["There is only one clock per device in the 4th PoC - value 1 should be used as instance-number."]
- },
- "two-step-flag": {
- "id": "two-step-flag",
- "type": "boolean",
- "order-number": 80,
- "is-read-only": true,
- "description": ["Indicates whether PTP clock is a two-step clock"]
- },
- "clock-quality": {
- "id": "clock-quality",
- "type": "",
- "order-number": 6,
- "is-read-only": true,
- "description": [""]
- },
- "clock-class": {
- "id": "clock-class",
- "type": "",
- "order-number": 7,
- "is-read-only": true,
- "description": ["Clock Class acc. to IEEE 1588-2008, 7.6.2.4 and ITU-T G.8275.1, 6.4"]
- },
- "clock-accuracy": {
- "id": "clock-accuracy",
- "type": "",
- "order-number": 8,
- "is-read-only": true,
- "description": ["Clock accuracy acc. to IEEE 1588-2008, 7.6.2.5 and ITU-T G.8275.1, 6.3.5"]
- },
- "offset-scaled-log-variance": {
- "id": "offset-scaled-log-variance",
- "type": "",
- "order-number": 9,
- "is-read-only": true,
- "description": ["Offset of scaled log variance acc. to IEEE 1588-2008, 7.6.3.5 and ITU-T G.8275.1, 6.3.5"]
- },
- "priority1": {
- "id": "priority1",
- "type": "number",
- "min": 0,
- "max": 255,
- "order-number": 10,
- "is-read-only": true,
- "description": ["Priority 1 acc. to IEEE 1588-2008, 7.6.2.2"]
- },
- "priority2": {
- "id": "priority2",
- "type": "number",
- "min": 0,
- "max": 255,
- "order-number": 11,
- "is-read-only": false,
- "description": ["Priority 2 acc. to IEEE 1588-2008, 7.6.2.3"]
- },
- "domain-number": {
- "id": "domain-number",
- "type": "number",
- "min": 24,
- "max": 43,
- "order-number": 12,
- "is-read-only": false,
- "description": ["PTP domain number acc. to IEEE 1588-2008, 7.1. See ptpDS.domainNumber."]
- },
- "slave-only": {
- "id": "slave-only",
- "type": "boolean",
- "order-number": 81,
- "is-read-only": false,
- "description": ["Indicates whether PTP clock may only operate as SC. See IEEE 1588-2008, 9.2."]
- },
- "current-ds": {
- "id": "current-ds",
- "type": "",
- "order-number": 14,
- "is-read-only": true,
- "description": [""]
- },
- "steps-removed": {
- "id": "steps-removed",
- "type": "",
- "order-number": 15,
- "is-read-only": true,
- "description": ["Number of communication paths traversed between local clock and GM"]
- },
- "offset-from-master": {
- "id": "offset-from-master",
- "type": "",
- "order-number": 16,
- "is-read-only": true,
- "unit": "ns*2^16",
- "description": ["Time off-set from master"]
- },
- "mean-path-delay": {
- "id": "mean-path-delay",
- "type": "",
- "order-number": 17,
- "is-read-only": true,
- "unit": "ns*2^16",
- "description": ["Mean propagation time between master and slave"]
- },
- "parrent-ds": {
- "id": "parrent-ds",
- "type": "",
- "order-number": 18,
- "is-read-only": true,
- "description": [""]
- },
- "parent-port-identity": {
- "id": "parent-port-identity",
- "type": "",
- "order-number": 19,
- "is-read-only": true,
- "description": [""]
- },
- "parent-stats": {
- "id": "parent-stats",
- "type": "",
- "order-number": 22,
- "is-read-only": true,
- "description": ["Indicates whether there are valid parent stats."]
- },
- "observed-parent-offset-scaled-log-variance": {
- "id": "observed-parent-offset-scaled-log-variance",
- "type": "",
- "order-number": 23,
- "is-read-only": true,
- "description": ["Estimate of parent's clock PTP variance as observed by slave clock acc. to IEEE 1588-2008, 7.6.4.4."]
- },
- "observed-parent-clock-phase-change-rate": {
- "id": "observed-parent-clock-phase-change-rate",
- "type": "",
- "order-number": 24,
- "is-read-only": true,
- "description": ["Estimate of parent's clock PTP phase change rate as observed by slave clock acc. to IEEE 1588-2008, 7.6.4.4."]
- },
- "grandmaster-identity": {
- "id": "grandmaster-identity",
- "type": "",
- "order-number": 25,
- "is-read-only": true,
- "description": ["Grandmaster clock ID acc. to IEEE 1588-2008, 7.6.2.1"]
- },
- "grandmaster-clock-quality": {
- "id": "grandmaster-clock-quality",
- "type": "",
- "order-number": 26,
- "is-read-only": true,
- "description": [""]
- },
- "grandmaster-priority1": {
- "id": "grandmaster-priority1",
- "type": "",
- "order-number": 30,
- "is-read-only": true,
- "description": ["Grandmaster's priority 1 acc. to IEEE 1588-2008, 7.6.2.2"]
- },
- "grandmaster-priority2": {
- "id": "grandmaster-priority2",
- "type": "",
- "order-number": 31,
- "is-read-only": true,
- "description": ["Grandmaster's priority 2 acc. to IEEE 1588-2008, 7.6.2.3"]
- },
- "time-properties-ds": {
- "id": "time-properties-ds",
- "type": "",
- "order-number": 32,
- "is-read-only": true,
- "description": [""]
- },
- "current-utc-offset-valid": {
- "id": "current-utc-offset-valid",
- "type": "",
- "order-number": 33,
- "is-read-only": true,
- "description": ["Indicates wheterh current UTC offset is correct."]
- },
- "current-utc-offset": {
- "id": "current-utc-offset",
- "type": "",
- "order-number": 34,
- "is-read-only": true,
- "description": ["Offset between TAI and UTC acc. to IEEE 1588-2008, 7.2.3"]
- },
- "leap59": {
- "id": "leap59",
- "type": "",
- "order-number": 35,
- "is-read-only": true,
- "description": ["Inidcates that last minute of current UTC day has 59 seconds."]
- },
- "leap61": {
- "id": "leap61",
- "type": "",
- "order-number": 36,
- "is-read-only": true,
- "description": ["Inidcates that last minute of current UTC day has 61 seconds."]
- },
- "time-tracable": {
- "id": "time-tracable",
- "type": "",
- "order-number": 37,
- "is-read-only": true,
- "description": ["Indicates that current UTC offset and timescale are traceable to a PRC"]
- },
- "frequency-tracable": {
- "id": "frequency-tracable",
- "type": "",
- "order-number": 38,
- "is-read-only": true,
- "description": ["Indicates that frequency determining timescale is traceable to a PRC"]
- },
- "ptp-timescale": {
- "id": "ptp-timescale",
- "type": "",
- "order-number": 39,
- "is-read-only": true,
- "description": ["Indicates thet timescale of grandmaster clock is PTP."]
- },
- "time-source": {
- "id": "time-source",
- "type": "",
- "order-number": 40,
- "is-read-only": true,
- "description": ["Time source used by grandmaster. See IEEE 1588-2008, 7.6.2.6."]
- },
- "port-state": {
- "id": "port-state",
- "type": "",
- "order-number": 45,
- "is-read-only": true,
- "description": ["State of this local port"]
- },
- "log-min-delay-req-interval": {
- "id": "log-min-delay-req-interval",
- "type": "",
- "order-number": 46,
- "is-read-only": true,
- "description": ["Minimum permitted mean time interval between successive Delay_Req messages"]
- },
- "peer-mean-path-delay": {
- "id": "peer-mean-path-delay",
- "type": "",
- "order-number": 47,
- "is-read-only": true,
- "unit": "ns*2^16",
- "description": ["Not applicable with this profile"]
- },
- "log-announce-interval": {
- "id": "log-announce-interval",
- "type": "",
- "order-number": 48,
- "is-read-only": true,
- "description": ["Mean time interval between successive Announce messages"]
- },
- "announce-receipt-timeout": {
- "id": "announce-receipt-timeout",
- "type": "",
- "order-number": 49,
- "is-read-only": true,
- "description": ["Number of announce intervals w/o announce message before timeout acc. to IEEE 1588-2008, 7.7.3.1."]
- },
- "log-sync-interval": {
- "id": "log-sync-interval",
- "type": "",
- "order-number": 50,
- "is-read-only": true,
- "description": ["Mean SyncInterval for multicast messages"]
- },
- "delay-mechanism": {
- "id": "delay-mechanism",
- "type": "string",
- "controlType": "text",
- "order-number": 51,
- "is-read-only": true,
- "description": ["Delay mechanism acc. to IEEE 1588-2008, 8.2.5.4.4."]
- },
- "version-number": {
- "id": "version-number",
- "type": "",
- "order-number": 53,
- "is-read-only": true,
- "description": ["PTP version used on this port"]
- },
- "transparent-clock-default-ds": {
- "id": "transparent-clock-default-ds",
- "type": "",
- "order-number": 54,
- "is-read-only": true,
- "description": [""]
- },
- "number-ports": {
- "id": "number-ports",
- "type": "",
- "order-number": -6,
- "is-read-only": true,
- "description": ["Number of ports of the device"]
- },
- "primary-domain": {
- "id": "primary-domain",
- "type": "",
- "order-number": 58,
- "is-read-only": true,
- "description": ["Domain number of primary syntonization domain acc. to IEEE 1588-2008, 10.1"]
- },
- "transparent-clock-port-ds-list": {
- "id": "transparent-clock-port-ds-list",
- "type": "",
- "order-number": 59,
- "is-read-only": true,
- "description": [""]
- },
- "log-min-pdelay-req-interval": {
- "id": "log-min-pdelay-req-interval",
- "type": "",
- "order-number": 63,
- "is-read-only": true,
- "description": ["Not applicable with this profile"]
- },
- "faulty-flag": {
- "id": "faulty-flag",
- "type": "",
- "order-number": 64,
- "is-read-only": true,
- "description": ["Indicates whether port is faulty."]
- },
- "default-ds": {
- "id": "default-ds",
- "type": "",
- "order-number": 68,
- "is-read-only": true,
- "description": [""]
- },
- "local-priority": {
- "id": "local-priority",
- "type": "number",
- "min": 1,
- "max": 255,
- "order-number": 69,
- "is-read-only": true,
- "description": ["See ITU-T G.8275.1, 6.3.2."]
- },
- "max-steps-removed": {
- "id": "max-steps-removed",
- "type": "number",
- "min": 1,
- "max": 255,
- "order-number": 70,
- "is-read-only": true,
- "description": ["See ITU-T G.8275.1, 6.3."]
- },
- "port-ds-list": {
- "id": "port-ds-list",
- "type": "",
- "order-number": 73,
- "is-read-only": true,
- "description": [""]
- },
- "clock-identity": {
- "id": "clock-identity",
- "type": "",
- "order-number": -10,
- "is-read-only": true,
- "description": ["ID of the local clock"]
- },
- "port-number": {
- "id": "port-number",
- "type": "",
- "order-number": 76,
- "is-read-only": true,
- "description": ["Port number of this port on the local clock"]
- },
- "onf-ptp-dataset:master-only": {
- "id": "onf-ptp-dataset:master-only",
- "type": "boolean",
- "order-number": 83,
- "is-read-only": false,
- "description": ["Indicates that port can only be a master."]
- },
- "onf-ptp-dataset:local-priority": {
- "id": "onf-ptp-dataset:local-priority",
- "type": "number",
- "min":1,
- "max":255,
- "order-number": -2,
- "is-read-only": false,
- "description": ["Local priority as used for Alternate BMCA. See ITU-T G.8275.1, 6.3.2."]
- },
- "onf-ptp-dataset:designated-enabled": {
- "id": "onf-ptp-dataset:designated-enabled",
- "type": "boolean",
- "order-number": 82,
- "is-read-only": false,
- "description": ["A PTP Port needs to be enabled by management acc. to IEEE 1588-2008, 9.2."]
- },
- "onf-ptp-dataset:delay-asymmetry": {
- "id": "onf-ptp-dataset:delay-asymmetry",
- "type": "number",
- "order-number": 80,
- "is-read-only": true,
- "description": ["Known path asymmetry in ns acc. to IEEE 1588-2008, 7.4.2."]
- },
- "onf-ptp-dataset:logical-termination-point": {
- "id": "onf-ptp-dataset:logical-termination-point ",
- "type": "string",
- "order-number": 81,
- "is-read-only": true,
- "description": [""]
- },
- "onf-ptp-dataset:multicast-mac-address": {
- "id": "onf-ptp-dataset:multicast-mac-address",
- "type": "",
- "order-number": -5,
- "is-read-only": true,
- "description": ["In 4th PoC the value is fixed."]
- },
- "onf-ptp-dataset:max-steps-removed": {
- "id": "onf-ptp-dataset:max-steps-removed",
- "type": "number",
- "min":1,
- "max":255,
- "order-number": 70,
- "is-read-only": false,
- "description": ["See ITU-T G.8275.1, 6.3."]
- }
- }
-}