diff options
Diffstat (limited to 'sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json')
-rw-r--r-- | sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json | 602 |
1 files changed, 602 insertions, 0 deletions
diff --git a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json new file mode 100644 index 000000000..b8e4d4ab6 --- /dev/null +++ b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json @@ -0,0 +1,602 @@ +{ + "schema-information": { + "otn-current-data": { + "id": "otn-current-data", + "uml-id": "_OxyHAOGJEeGhaeLtr7IxXg", + "uml-type": "uml:Class", + "is-read-only": false, + "description": [ + "This object class is an abstract class from which the OTN layer-specific CurrentData object classes are inherited. This object class is a subclass of the Q.822 CurrentData object class, which in turn is a subclass of X.739 Scanner object class. It inherits the following attributes: scannerId, operationalState, granularityPeriod, administrativeState, suspectIntervalFlag, elapsedTime, observedObjectClass, and observedObjectInstance." + ], + "uml-name": "OTN_CurrentData" + }, + "timestamp": { + "id": "timestamp", + "uml-id": "_bGwfoOGJEeGhaeLtr7IxXg", + "uml-type": "ownedAttribute", + "type": "_X-HZUNwbEeGoneTbGt8X0A", + "order-number": 1, + "is-read-only": false, + "description": [ + "The timestamp associated with when the current data was collected." + ], + "uml-name": "timestamp" + }, + "otn-history-data": { + "id": "otn-history-data", + "uml-id": "_dQ2mYOGOEeGhaeLtr7IxXg", + "uml-type": "uml:Class", + "is-read-only": false, + "description": [ + "This object class is an abstract class from which the OTN layer-specific HistoryData object classes are inherited." + ], + "uml-name": "OTN_HistoryData" + }, + "suspect-interval-flag": { + "id": "suspect-interval-flag", + "uml-id": "_M8IDNceIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Boolean", + "order-number": 1, + "is-read-only": false, + "description": [ + "This attribute is used to indicate that the performance data for the current period may not be reliable. Some reasons for this to occur are:- Suspect data were detected by the actual resource doing data collection.- Transition of the administrativeState attribute to/from the 'lock' state.- Transition of the operationalState to/from the 'disabled' state.- Scheduler setting that inhibits the collection function.- The performance counters were reset during the interval.- The currentData (or subclass) object instance was created during the monitoring period." + ], + "uml-name": "suspectIntervalFlag", + "controlType": "checkbox" + }, + "«q.822»-current-data": { + "id": "«q.822»-current-data", + "uml-id": "_M8IDMceIEeSfd5vyUJsimg", + "uml-type": "uml:Class", + "is-read-only": false, + "uml-name": "«Q.822»-CurrentData" + }, + "elapsed-time": { + "id": "elapsed-time", + "uml-id": "_M8IDOMeIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Integer", + "order-number": 2, + "is-read-only": false, + "uml-name": "elapsedTime", + "controlType": "number" + }, + "«q.822»-history-data": { + "id": "«q.822»-history-data", + "uml-id": "_M8IDVMeIEeSfd5vyUJsimg", + "uml-type": "uml:Class", + "is-read-only": false, + "uml-name": "«Q.822»-HistoryData" + }, + "history-data-id": { + "id": "history-data-id", + "uml-id": "_M8IDWMeIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String", + "order-number": 1, + "is-read-only": false, + "uml-name": "historyDataId", + "controlType": "text" + }, + "period-end-time": { + "id": "period-end-time", + "uml-id": "_M8IDWceIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "../OnfModel-CoreModel/CoreModel.uml#_oGqi1lLNEeO75dO39GbF8Q", + "order-number": 2, + "is-read-only": false, + "uml-name": "periodEndTime" + }, + "granularity-period": { + "id": "granularity-period", + "uml-id": "_M8IDWseIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "_Y6WUEEamEeabNPX3o7rjtw", + "order-number": 2, + "is-read-only": false, + "uml-name": "granularityPeriod", + "controlType": [ + "unknown", + "period-15-min", + "period-24-hours" + ] + }, + "«x.739»-scanner": { + "id": "«x.739»-scanner", + "uml-id": "_7wb90ceIEeSfd5vyUJsimg", + "uml-type": "uml:Class", + "is-read-only": false, + "uml-name": "«X.739»-Scanner" + }, + "scanner-id": { + "id": "scanner-id", + "uml-id": "_7wb91ceIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String", + "order-number": 1, + "is-read-only": false, + "uml-name": "scannerId", + "controlType": "text" + }, + "administrative-state": { + "id": "administrative-state", + "uml-id": "_7wb92seIEeSfd5vyUJsimg", + "uml-type": "ownedAttribute", + "type": "../OnfModel-CoreModel/CoreModel.uml#_KSKOYLEuEeSZUdYfPSdgew", + "order-number": 3, + "is-read-only": false, + "uml-name": "administrativeState" + }, + "«x.721»-top": { + "id": "«x.721»-top", + "uml-id": "_BMJ0EceTEeS6-cawxfHpnA", + "uml-type": "uml:Class", + "is-read-only": false, + "description": [ + "This is the top level of managed object class hierarchy and every other managed object class is a specialization of either this generic class (top) or a specialization of subclass of top. The parameter miscellaneousError is to be used when a processing failure has occurred and the error condition encountered does not match any of object's defined specific error types." + ], + "uml-name": "«X.721»-Top" + }, + "object-class": { + "id": "object-class", + "uml-id": "_BMJ0FceTEeS6-cawxfHpnA", + "uml-type": "ownedAttribute", + "type": "_ltGzFMeUEeS6-cawxfHpnA", + "order-number": 1, + "is-read-only": false, + "description": [ + "ObjectClass ::= CHOICE{ globalForm [0] OBJECT IDENTIFIER, localForm [1] INTEGER}" + ], + "uml-name": "objectClass" + }, + "name-binding": { + "id": "name-binding", + "uml-id": "_BMJ0F8eTEeS6-cawxfHpnA", + "uml-type": "ownedAttribute", + "type": "_ltGzFMeUEeS6-cawxfHpnA", + "order-number": 2, + "is-read-only": false, + "uml-name": "nameBinding" + }, + "date-and-time": { + "id": "date-and-time", + "uml-id": "_X-HZUNwbEeGoneTbGt8X0A", + "uml-type": "uml:DataType", + "description": [ + "This primitive type defines the date and time according to the following structure: yyyyMMddhhmmss.s[Z|{+|-}HHMm] where: yyyy 0000 .. 9999 year MM 01 .. 12 month dd 01 .. 31 day hh 00 .. 23 hour mm 00 .. 59 minute ss 00 .. 59 second s .0 .. .9 tenth of second (set to .0 if EMS or NE cannot support this granularity) Z Z indicates UTC (rather than local time) {+|-} + or - delta from UTC HH 00 .. 23 time zone difference in hours Mm 00 .. 59 time zone difference in minutes." + ], + "uml-name": "DateAndTime" + }, + "5-g6-yq-oo-ee-cj-nnlz-cc6-mew": { + "id": "5-g6-yq-oo-ee-cj-nnlz-cc6-mew", + "uml-id": "_5G6YQOo-EeCjNNLZCc6mew", + "enum": [ + "SINK", + "SOURCE", + "BIDIRECTIONAL" + ], + "is-read-only": false, + "description": [ + "The enumeration with the options for directionality of the termination point." + ], + "uml-name": "_5G6YQOo-EeCjNNLZCc6mew" + }, + "r-u8-a-m-opf-ee-cj-nnlz-cc6-mew": { + "id": "r-u8-a-m-opf-ee-cj-nnlz-cc6-mew", + "uml-id": "_rU8aMOpfEeCjNNLZCc6mew", + "enum": [ + "GCC1", + "GCC2", + "GCC1_AND_GCC2" + ], + "is-read-only": false, + "description": [ + "This enumeration indicates the GCC access represented by the entity." + ], + "uml-name": "_rU8aMOpfEeCjNNLZCc6mew" + }, + "w7-1-o-opi-ee-cj-nnlz-cc6-mew": { + "id": "w7-1-o-opi-ee-cj-nnlz-cc6-mew", + "uml-id": "_W7-1oOpiEeCjNNLZCc6mew", + "enum": [ + "ENABLED", + "DISABLED" + ], + "is-read-only": false, + "description": [ + "The list of valid operational states for the connection." + ], + "uml-name": "_W7-1oOpiEeCjNNLZCc6mew" + }, + "g0-z-cs-os-d-ee-cj-nnlz-cc6-mew": { + "id": "g0-z-cs-os-d-ee-cj-nnlz-cc6-mew", + "uml-id": "_g0zCsOsDEeCjNNLZCc6mew", + "enum": [ + "REVERTIVE", + "NON-REVERTIVE" + ], + "is-read-only": false, + "description": [ + "The operation type associated with the protection mechanism (either non-revertive or revertive)." + ], + "uml-name": "_g0zCsOsDEeCjNNLZCc6mew" + }, + "jl09-g-os-k-ee-cj-nnlz-cc6-mew": { + "id": "jl09-g-os-k-ee-cj-nnlz-cc6-mew", + "uml-id": "_Jl09gOsKEeCjNNLZCc6mew", + "enum": [ + "EXERCISE", + "MANUAL_SWITCH", + "FORCED_SWITCH", + "LOCKOUT", + "RELEASE_OF_MANUAL_SWITCH", + "RELEASE_OF_FORCED_SWITCH", + "RELEASE_OF_LOCKOUT" + ], + "is-read-only": false, + "description": [ + "This enumeration contains the options for the actions that instruct the protection system for performing specific protection switching operations." + ], + "uml-name": "_Jl09gOsKEeCjNNLZCc6mew" + }, + "bwx-bq-ow5-ee-cj-nnlz-cc6-mew": { + "id": "bwx-bq-ow5-ee-cj-nnlz-cc6-mew", + "uml-id": "_bwxBQOw5EeCjNNLZCc6mew", + "enum": [ + "UNLOCKED", + "LOCKED", + "SHUTTING_DOWN" + ], + "is-read-only": false, + "description": [ + "For more information on Administrative State, See ITU-T Recs. X.731 and M.3100." + ], + "uml-name": "_bwxBQOw5EeCjNNLZCc6mew" + }, + "ch-q5-o-ow-ee-cj-nnlz-cc6-mew": { + "id": "ch-q5-o-ow-ee-cj-nnlz-cc6-mew", + "uml-id": "_ChQ5oOw-EeCjNNLZCc6mew", + "enum": [ + "2.5_G", + "10_G", + "40_G", + "100_G" + ], + "is-read-only": false, + "description": [ + "Provides an enumeration with the meaning of each k value." + ], + "uml-name": "_ChQ5oOw-EeCjNNLZCc6mew" + }, + "z-bty-u-ow-ee-cj-nnlz-cc6-mew": { + "id": "z-bty-u-ow-ee-cj-nnlz-cc6-mew", + "uml-id": "_ZBtyUOw_EeCjNNLZCc6mew", + "enum": [ + "DAPI", + "SAPI", + "BOTH" + ], + "is-read-only": false, + "description": [ + "List of modes for trace identifier mismatch detection." + ], + "uml-name": "_ZBtyUOw_EeCjNNLZCc6mew" + }, + "hf864-ox-a-ee-cj-nnlz-cc6-mew": { + "id": "hf864-ox-a-ee-cj-nnlz-cc6-mew", + "uml-id": "_HF864OxAEeCjNNLZCc6mew", + "enum": [ + "LOS_P", + "OCI", + "SSF_P", + "SSF_O", + "SSF", + "TIM", + "DEG", + "BDI" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_HF864OxAEeCjNNLZCc6mew" + }, + "w-po-no-o3-e-ee-cj-nnlz-cc6-mew": { + "id": "w-po-no-o3-e-ee-cj-nnlz-cc6-mew", + "uml-id": "_WPoNoO3eEeCjNNLZCc6mew", + "enum": [ + "INTRUSIVE", + "NON-INTRUSIVE" + ], + "is-read-only": false, + "description": [ + "Monitoring types for the tandem connection monitoring function." + ], + "uml-name": "_WPoNoO3eEeCjNNLZCc6mew" + }, + "oi-7-w-o6-q-ee-cj-nnlz-cc6-mew": { + "id": "oi-7-w-o6-q-ee-cj-nnlz-cc6-mew", + "uml-id": "_OI-7wO6QEeCjNNLZCc6mew", + "enum": [ + "OPERATIONAL", + "TRANSPARENT", + "MONITOR" + ], + "is-read-only": false, + "description": [ + "List of value modes for the sink side of the tandem connection monitoring function." + ], + "uml-name": "_OI-7wO6QEeCjNNLZCc6mew" + }, + "zn-m8-c-o6-z-ee-cj-nnlz-cc6-mew": { + "id": "zn-m8-c-o6-z-ee-cj-nnlz-cc6-mew", + "uml-id": "_ZnM8cO6ZEeCjNNLZCc6mew", + "enum": [ + "40_G", + "100_G" + ], + "is-read-only": false, + "description": [ + "Provides an enumeration with the meaning of each k value." + ], + "uml-name": "_ZnM8cO6ZEeCjNNLZCc6mew" + }, + "p-v-f8-o6-a-ee-cj-nnlz-cc6-mew": { + "id": "p-v-f8-o6-a-ee-cj-nnlz-cc6-mew", + "uml-id": "_pV-F8O6aEeCjNNLZCc6mew", + "enum": [ + "LOS", + "LOL" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_pV-F8O6aEeCjNNLZCc6mew" + }, + "qw1-syo6-b-ee-cj-nnlz-cc6-mew": { + "id": "qw1-syo6-b-ee-cj-nnlz-cc6-mew", + "uml-id": "_QW1SYO6bEeCjNNLZCc6mew", + "enum": [ + "LOS" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_QW1SYO6bEeCjNNLZCc6mew" + }, + "o-ouk-o6-b-ee-cj-nnlz-cc6-mew": { + "id": "o-ouk-o6-b-ee-cj-nnlz-cc6-mew", + "uml-id": "_o-oukO6bEeCjNNLZCc6mew", + "enum": [ + "2.5_G", + "10_G", + "40_G", + "2.5_10_G", + "10_40_G", + "2.5_10_40_G" + ], + "is-read-only": false, + "description": [ + "Provides an enumeration with the meaning of each k value." + ], + "uml-name": "_o-oukO6bEeCjNNLZCc6mew" + }, + "krcg4-o6-d-ee-cj-nnlz-cc6-mew": { + "id": "krcg4-o6-d-ee-cj-nnlz-cc6-mew", + "uml-id": "_KRCG4O6dEeCjNNLZCc6mew", + "enum": [ + "INTRA_DOMAIN", + "INTER_DOMAIN" + ], + "is-read-only": false, + "description": [ + "This enumeration provides the options for the interface associated with OTMn." + ], + "uml-name": "_KRCG4O6dEeCjNNLZCc6mew" + }, + "eo-py-io6-q-ee-cj-nnlz-cc6-mew": { + "id": "eo-py-io6-q-ee-cj-nnlz-cc6-mew", + "uml-id": "_EOPyIO6qEeCjNNLZCc6mew", + "enum": [ + "INTRA_OFFICE", + "SHORTHAUL", + "LONGHAUL" + ], + "is-read-only": false, + "description": [ + "The valid options for reach of the optical cable." + ], + "uml-name": "_EOPyIO6qEeCjNNLZCc6mew" + }, + "6-bt3-qo6-q-ee-cj-nnlz-cc6-mew": { + "id": "6-bt3-qo6-q-ee-cj-nnlz-cc6-mew", + "uml-id": "_6Bt3QO6qEeCjNNLZCc6mew", + "enum": [ + "ON", + "OFF" + ], + "is-read-only": false, + "description": [ + "The enumeration of the options for the Automatic Power Reduction Status." + ], + "uml-name": "_6Bt3QO6qEeCjNNLZCc6mew" + }, + "f-lz-nqo6-v-ee-cj-nnlz-cc6-mew": { + "id": "f-lz-nqo6-v-ee-cj-nnlz-cc6-mew", + "uml-id": "_FLzNQO6vEeCjNNLZCc6mew", + "enum": [ + "BDI_P", + "BDI_O", + "BDI", + "TIM", + "LOS_P", + "LOS_O", + "LOS" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_FLzNQO6vEeCjNNLZCc6mew" + }, + "na-el-yo6-w-ee-cj-nnlz-cc6-mew": { + "id": "na-el-yo6-w-ee-cj-nnlz-cc6-mew", + "uml-id": "_NAElYO6wEeCjNNLZCc6mew", + "enum": [ + "REGULAR", + "NONE", + "VENDOR_SPECIFIC", + "FUNCTIONALLY_STANDARDIZED" + ], + "is-read-only": false, + "description": [ + "The adaptation options for OTUk_ConnectionTermationPoints." + ], + "uml-name": "_NAElYO6wEeCjNNLZCc6mew" + }, + "wg-r-hc-o6-w-ee-cj-nnlz-cc6-mew": { + "id": "wg-r-hc-o6-w-ee-cj-nnlz-cc6-mew", + "uml-id": "_wgRHcO6wEeCjNNLZCc6mew", + "enum": [ + "2.5_G", + "10_G", + "40_G", + "100_G" + ], + "is-read-only": false, + "description": [ + "Provides an enumeration with the meaning of each k value." + ], + "uml-name": "_wgRHcO6wEeCjNNLZCc6mew" + }, + "6-y-g-eo6-w-ee-cj-nnlz-cc6-mew": { + "id": "6-y-g-eo6-w-ee-cj-nnlz-cc6-mew", + "uml-id": "_6Y_gEO6wEeCjNNLZCc6mew", + "enum": [ + "LOF", + "AIS", + "LOM" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_6Y_gEO6wEeCjNNLZCc6mew" + }, + "x-hnwmo6-x-ee-cj-nnlz-cc6-mew": { + "id": "x-hnwmo6-x-ee-cj-nnlz-cc6-mew", + "uml-id": "_xHNWMO6xEeCjNNLZCc6mew", + "enum": [ + "TIM", + "DEG", + "BDI", + "SSF" + ], + "is-read-only": false, + "description": [ + "The valid list of problems for the entity." + ], + "uml-name": "_xHNWMO6xEeCjNNLZCc6mew" + }, + "krq3-mk8-k-ee-g-z-yhf-u3-o-m-yg": { + "id": "krq3-mk8-k-ee-g-z-yhf-u3-o-m-yg", + "uml-id": "_KRQ3MK8KEeG_zYhfU3oMYg", + "enum": [ + "SINK", + "SOURCE" + ], + "is-read-only": false, + "description": [ + "The enumeration with the options for directionality for nonintrusive monitoring." + ], + "uml-name": "_KRQ3MK8KEeG_zYhfU3oMYg" + }, + "q-bme4-lu-y-ee-geq-z-lpdv-u3-ba": { + "id": "q-bme4-lu-y-ee-geq-z-lpdv-u3-ba", + "uml-id": "_qBme4LuYEeGeqZLpdvU3BA", + "enum": [ + "PERCENTAGE", + "NUMBER_ERRORED_BLOCKS" + ], + "is-read-only": false, + "description": [ + "<p>The value of the threshold can be provisioned in terms of number of errored blocks or in terms of percentage of errored blocks. For percentage-based specification, in order to support provision of less than 1%, the specification consists of two fields. The first field indicates the granularity of percentage. For examples, in 1%, in 0.1%, or in 0.01%, etc. The second field indicates the multiple of the granularity. For number of errored block based, the value is a positive integer.</p>" + ], + "uml-name": "_qBme4LuYEeGeqZLpdvU3BA" + }, + "parz8-nw-a-ee-gone-tb-gt8-x0-a": { + "id": "parz8-nw-a-ee-gone-tb-gt8-x0-a", + "uml-id": "_Parz8NwAEeGoneTbGt8X0A", + "enum": [ + "DWDM", + "CWDM", + "NO_WDM" + ], + "is-read-only": false, + "uml-name": "_Parz8NwAEeGoneTbGt8X0A" + }, + "v1-tu-a-nw-a-ee-gone-tb-gt8-x0-a": { + "id": "v1-tu-a-nw-a-ee-gone-tb-gt8-x0-a", + "uml-id": "_V1TuANwAEeGoneTbGt8X0A", + "enum": [ + "STANDARD", + "PROPRIETARY" + ], + "is-read-only": false, + "uml-name": "_V1TuANwAEeGoneTbGt8X0A" + }, + "yt7-s4-pzg-ee-g3-u-a-qk-ii-ctg": { + "id": "yt7-s4-pzg-ee-g3-u-a-qk-ii-ctg", + "uml-id": "_yt7S4PzgEeG3u-aQKIiCtg", + "enum": [ + "PATH", + "TCM1", + "TCM2", + "TCM3", + "TCM4", + "TCM5", + "TCM6", + "SECTION" + ], + "is-read-only": false, + "uml-name": "_yt7S4PzgEeG3u-aQKIiCtg" + }, + "lg3-y-qovv-ee-ky-u85-edu-w-r-a": { + "id": "lg3-y-qovv-ee-ky-u85-edu-w-r-a", + "uml-id": "_LG3yQOVVEeKyU85eduW_rA", + "enum": [ + "CONTROLLER", + "RESPONDER" + ], + "is-read-only": false, + "uml-name": "_LG3yQOVVEeKyU85eduW_rA" + }, + "7-fy9-s-jsc-ee-o-lx-kcui-ytz-cg": { + "id": "7-fy9-s-jsc-ee-o-lx-kcui-ytz-cg", + "uml-id": "_7fy9sJSCEeOLxKCUIYtzCg", + "enum": [ + "INCREASE_BW", + "DECREASE_BW" + ], + "is-read-only": false, + "uml-name": "_7fy9sJSCEeOLxKCUIYtzCg" + }, + "y6-wue-eam-eeab-npx3-o7-rjtw": { + "id": "y6-wue-eam-eeab-npx3-o7-rjtw", + "uml-id": "_Y6WUEEamEeabNPX3o7rjtw", + "enum": [ + "UNKNOWN", + "PERIOD_15MIN", + "PERIOD_24HOURS" + ], + "is-read-only": false, + "description": [ + "The enumeration with the options for granularity period of the performance data." + ], + "uml-name": "_Y6WUEEamEeabNPX3o7rjtw" + } + } +}
\ No newline at end of file |