summaryrefslogtreecommitdiffstats
path: root/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json
diff options
context:
space:
mode:
Diffstat (limited to 'sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json')
-rw-r--r--sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json546
1 files changed, 546 insertions, 0 deletions
diff --git a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json
new file mode 100644
index 000000000..5c5daa757
--- /dev/null
+++ b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/G.874.1-ForMicrowave.json
@@ -0,0 +1,546 @@
+{
+ "schema-information": {
+ "OTN_CurrentData": {
+ "id": "OTN_CurrentData",
+ "uml-id": "_OxyHAOGJEeGhaeLtr7IxXg",
+ "uml-type": "uml:Class",
+ "is-read-only": false,
+ "description": [
+ "This object class is an abstract class from which the OTN layer-specific CurrentData object classes are inherited. This object class is a subclass of the Q.822 CurrentData object class, which in turn is a subclass of X.739 Scanner object class. It inherits the following attributes: scannerId, operationalState, granularityPeriod, administrativeState, suspectIntervalFlag, elapsedTime, observedObjectClass, and observedObjectInstance."
+ ]
+ },
+ "timestamp": {
+ "id": "timestamp",
+ "uml-id": "_bGwfoOGJEeGhaeLtr7IxXg",
+ "uml-type": "ownedAttribute",
+ "type": "_X-HZUNwbEeGoneTbGt8X0A",
+ "order-number": 1,
+ "is-read-only": false,
+ "description": [
+ "The timestamp associated with when the current data was collected."
+ ]
+ },
+ "OTN_HistoryData": {
+ "id": "OTN_HistoryData",
+ "uml-id": "_dQ2mYOGOEeGhaeLtr7IxXg",
+ "uml-type": "uml:Class",
+ "is-read-only": false,
+ "description": [
+ "This object class is an abstract class from which the OTN layer-specific HistoryData object classes are inherited."
+ ]
+ },
+ "«Q.822»-CurrentData": {
+ "id": "«Q.822»-CurrentData",
+ "uml-id": "_M8IDMceIEeSfd5vyUJsimg",
+ "uml-type": "uml:Class",
+ "is-read-only": false
+ },
+ "suspectIntervalFlag": {
+ "id": "suspectIntervalFlag",
+ "uml-id": "_M8IDNceIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Boolean",
+ "order-number": 1,
+ "is-read-only": false,
+ "description": [
+ "This attribute is used to indicate that the performance data for the current period may not be reliable. Some reasons for this to occur are:- Suspect data were detected by the actual resource doing data collection.- Transition of the administrativeState attribute to/from the 'lock' state.- Transition of the operationalState to/from the 'disabled' state.- Scheduler setting that inhibits the collection function.- The performance counters were reset during the interval.- The currentData (or subclass) object instance was created during the monitoring period."
+ ]
+ },
+ "elapsedTime": {
+ "id": "elapsedTime",
+ "uml-id": "_M8IDOMeIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Integer",
+ "order-number": 2,
+ "is-read-only": false
+ },
+ "«Q.822»-HistoryData": {
+ "id": "«Q.822»-HistoryData",
+ "uml-id": "_M8IDVMeIEeSfd5vyUJsimg",
+ "uml-type": "uml:Class",
+ "is-read-only": false
+ },
+ "historyDataId": {
+ "id": "historyDataId",
+ "uml-id": "_M8IDWMeIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String",
+ "order-number": 1,
+ "is-read-only": false,
+ "is-key": 1
+ },
+ "periodEndTime": {
+ "id": "periodEndTime",
+ "uml-id": "_M8IDWceIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "../OnfModel-CoreModel/CoreModel.uml#_oGqi1lLNEeO75dO39GbF8Q",
+ "order-number": 2,
+ "is-read-only": false
+ },
+ "«X.739»-Scanner": {
+ "id": "«X.739»-Scanner",
+ "uml-id": "_7wb90ceIEeSfd5vyUJsimg",
+ "uml-type": "uml:Class",
+ "is-read-only": false
+ },
+ "scannerId": {
+ "id": "scannerId",
+ "uml-id": "_7wb91ceIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String",
+ "order-number": 1,
+ "is-read-only": false,
+ "is-key": 1
+ },
+ "granularityPeriod": {
+ "id": "granularityPeriod",
+ "uml-id": "_M8IDWseIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "_Y6WUEEamEeabNPX3o7rjtw",
+ "order-number": 2,
+ "is-read-only": false
+ },
+ "administrativeState": {
+ "id": "administrativeState",
+ "uml-id": "_7wb92seIEeSfd5vyUJsimg",
+ "uml-type": "ownedAttribute",
+ "type": "../OnfModel-CoreModel/CoreModel.uml#_KSKOYLEuEeSZUdYfPSdgew",
+ "order-number": 3,
+ "is-read-only": false
+ },
+ "«X.721»-Top": {
+ "id": "«X.721»-Top",
+ "uml-id": "_BMJ0EceTEeS6-cawxfHpnA",
+ "uml-type": "uml:Class",
+ "is-read-only": false,
+ "description": [
+ "This is the top level of managed object class hierarchy and every other managed object class is a specialization of either this generic class (top) or a specialization of subclass of top. The parameter miscellaneousError is to be used when a processing failure has occurred and the error condition encountered does not match any of object's defined specific error types."
+ ]
+ },
+ "objectClass": {
+ "id": "objectClass",
+ "uml-id": "_BMJ0FceTEeS6-cawxfHpnA",
+ "uml-type": "ownedAttribute",
+ "type": "_ltGzFMeUEeS6-cawxfHpnA",
+ "order-number": 1,
+ "is-read-only": false,
+ "description": [
+ "ObjectClass ::= CHOICE{ globalForm [0] OBJECT IDENTIFIER, localForm [1] INTEGER}"
+ ]
+ },
+ "nameBinding": {
+ "id": "nameBinding",
+ "uml-id": "_BMJ0F8eTEeS6-cawxfHpnA",
+ "uml-type": "ownedAttribute",
+ "type": "_ltGzFMeUEeS6-cawxfHpnA",
+ "order-number": 2,
+ "is-read-only": false
+ },
+ "DateAndTime": {
+ "id": "DateAndTime",
+ "uml-id": "_X-HZUNwbEeGoneTbGt8X0A",
+ "uml-type": "uml:DataType",
+ "description": [
+ "This primitive type defines the date and time according to the following structure: yyyyMMddhhmmss.s[Z|{+|-}HHMm] where: yyyy 0000 .. 9999 year MM 01 .. 12 month dd 01 .. 31 day hh 00 .. 23 hour mm 00 .. 59 minute ss 00 .. 59 second s .0 .. .9 tenth of second (set to .0 if EMS or NE cannot support this granularity) Z Z indicates UTC (rather than local time) {+|-} + or - delta from UTC HH 00 .. 23 time zone difference in hours Mm 00 .. 59 time zone difference in minutes."
+ ]
+ },
+ "_5G6YQOo-EeCjNNLZCc6mew": {
+ "id": "Directionality",
+ "uml-id": "_5G6YQOo-EeCjNNLZCc6mew",
+ "enum": [
+ "SINK",
+ "SOURCE",
+ "BIDIRECTIONAL"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The enumeration with the options for directionality of the termination point."
+ ]
+ },
+ "_rU8aMOpfEeCjNNLZCc6mew": {
+ "id": "GccAccess",
+ "uml-id": "_rU8aMOpfEeCjNNLZCc6mew",
+ "enum": [
+ "GCC1",
+ "GCC2",
+ "GCC1_AND_GCC2"
+ ],
+ "is-read-only": false,
+ "description": [
+ "This enumeration indicates the GCC access represented by the entity."
+ ]
+ },
+ "_W7-1oOpiEeCjNNLZCc6mew": {
+ "id": "OperationalState",
+ "uml-id": "_W7-1oOpiEeCjNNLZCc6mew",
+ "enum": [
+ "ENABLED",
+ "DISABLED"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The list of valid operational states for the connection."
+ ]
+ },
+ "_g0zCsOsDEeCjNNLZCc6mew": {
+ "id": "OperType",
+ "uml-id": "_g0zCsOsDEeCjNNLZCc6mew",
+ "enum": [
+ "REVERTIVE",
+ "NON-REVERTIVE"
+ ],
+ "is-read-only": [
+ "The operation type associated with the protection mechanism (either non-revertive or revertive)."
+ ]
+ },
+ "_Jl09gOsKEeCjNNLZCc6mew": {
+ "id": "ExtCmdOperation",
+ "uml-id": "_Jl09gOsKEeCjNNLZCc6mew",
+ "enum": [
+ "EXERCISE",
+ "MANUAL_SWITCH",
+ "FORCED_SWITCH",
+ "LOCKOUT",
+ "RELEASE_OF_MANUAL_SWITCH",
+ "RELEASE_OF_FORCED_SWITCH",
+ "RELEASE_OF_LOCKOUT"
+ ],
+ "is-read-only": false,
+ "description": [
+ "This enumeration contains the options for the actions that instruct the protection system for performing specific protection switching operations."
+ ]
+ },
+ "_bwxBQOw5EeCjNNLZCc6mew": {
+ "id": "AdministrativeState",
+ "uml-id": "_bwxBQOw5EeCjNNLZCc6mew",
+ "enum": [
+ "UNLOCKED",
+ "LOCKED",
+ "SHUTTING_DOWN"
+ ],
+ "is-read-only": false,
+ "description": [
+ "For more information on Administrative State, See ITU-T Recs. X.731 and M.3100."
+ ]
+ },
+ "_ChQ5oOw-EeCjNNLZCc6mew": {
+ "id": "OCTk_NimKBitRate",
+ "uml-id": "_ChQ5oOw-EeCjNNLZCc6mew",
+ "enum": [
+ "2.5_G",
+ "10_G",
+ "40_G",
+ "100_G"
+ ],
+ "is-read-only": false,
+ "description": [
+ "Provides an enumeration with the meaning of each k value."
+ ]
+ },
+ "_ZBtyUOw_EeCjNNLZCc6mew": {
+ "id": "TimDetMo",
+ "uml-id": "_ZBtyUOw_EeCjNNLZCc6mew",
+ "enum": [
+ "DAPI",
+ "SAPI",
+ "BOTH"
+ ],
+ "is-read-only": false,
+ "description": [
+ "List of modes for trace identifier mismatch detection."
+ ]
+ },
+ "_HF864OxAEeCjNNLZCc6mew": {
+ "id": "OCTk_NimProblemList",
+ "uml-id": "_HF864OxAEeCjNNLZCc6mew",
+ "enum": [
+ "LOS_P",
+ "OCI",
+ "SSF_P",
+ "SSF_O",
+ "SSF",
+ "TIM",
+ "DEG",
+ "BDI"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_WPoNoO3eEeCjNNLZCc6mew": {
+ "id": "TcmMonitoring",
+ "uml-id": "_WPoNoO3eEeCjNNLZCc6mew",
+ "enum": [
+ "INTRUSIVE",
+ "NON-INTRUSIVE"
+ ],
+ "is-read-only": false,
+ "description": [
+ "Monitoring types for the tandem connection monitoring function."
+ ]
+ },
+ "_OI-7wO6QEeCjNNLZCc6mew": {
+ "id": "TcmMode",
+ "uml-id": "_OI-7wO6QEeCjNNLZCc6mew",
+ "enum": [
+ "OPERATIONAL",
+ "TRANSPARENT",
+ "MONITOR"
+ ],
+ "is-read-only": false,
+ "description": [
+ "List of value modes for the sink side of the tandem connection monitoring function."
+ ]
+ },
+ "_ZnM8cO6ZEeCjNNLZCc6mew": {
+ "id": "OPSMnk_TtpKBitRate",
+ "uml-id": "_ZnM8cO6ZEeCjNNLZCc6mew",
+ "enum": [
+ "40_G",
+ "100_G"
+ ],
+ "is-read-only": false,
+ "description": [
+ "Provides an enumeration with the meaning of each k value."
+ ]
+ },
+ "_pV-F8O6aEeCjNNLZCc6mew": {
+ "id": "OPSMnk_TtpProblemList",
+ "uml-id": "_pV-F8O6aEeCjNNLZCc6mew",
+ "enum": [
+ "LOS",
+ "LOL"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_QW1SYO6bEeCjNNLZCc6mew": {
+ "id": "OPSn_TtpProblemList",
+ "uml-id": "_QW1SYO6bEeCjNNLZCc6mew",
+ "enum": [
+ "LOS"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_o-oukO6bEeCjNNLZCc6mew": {
+ "id": "OTM-n_KBitRates",
+ "uml-id": "_o-oukO6bEeCjNNLZCc6mew",
+ "enum": [
+ "2.5_G",
+ "10_G",
+ "40_G",
+ "2.5_10_G",
+ "10_40_G",
+ "2.5_10_40_G"
+ ],
+ "is-read-only": false,
+ "description": [
+ "Provides an enumeration with the meaning of each k value."
+ ]
+ },
+ "_KRCG4O6dEeCjNNLZCc6mew": {
+ "id": "DomainInterface",
+ "uml-id": "_KRCG4O6dEeCjNNLZCc6mew",
+ "enum": [
+ "INTRA_DOMAIN",
+ "INTER_DOMAIN"
+ ],
+ "is-read-only": false,
+ "description": [
+ "This enumeration provides the options for the interface associated with OTMn."
+ ]
+ },
+ "_EOPyIO6qEeCjNNLZCc6mew": {
+ "id": "OTM-n_OpticalReach",
+ "uml-id": "_EOPyIO6qEeCjNNLZCc6mew",
+ "enum": [
+ "INTRA_OFFICE",
+ "SHORTHAUL",
+ "LONGHAUL"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid options for reach of the optical cable."
+ ]
+ },
+ "_6Bt3QO6qEeCjNNLZCc6mew": {
+ "id": "AprStatus",
+ "uml-id": "_6Bt3QO6qEeCjNNLZCc6mew",
+ "enum": [
+ "ON",
+ "OFF"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The enumeration of the options for the Automatic Power Reduction Status."
+ ]
+ },
+ "_FLzNQO6vEeCjNNLZCc6mew": {
+ "id": "OTSn_TtpProblemList",
+ "uml-id": "_FLzNQO6vEeCjNNLZCc6mew",
+ "enum": [
+ "BDI_P",
+ "BDI_O",
+ "BDI",
+ "TIM",
+ "LOS_P",
+ "LOS_O",
+ "LOS"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_NAElYO6wEeCjNNLZCc6mew": {
+ "id": "OTUk_CtpAdaptation",
+ "uml-id": "_NAElYO6wEeCjNNLZCc6mew",
+ "enum": [
+ "REGULAR",
+ "NONE",
+ "VENDOR_SPECIFIC",
+ "FUNCTIONALLY_STANDARDIZED"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The adaptation options for OTUk_ConnectionTermationPoints."
+ ]
+ },
+ "_wgRHcO6wEeCjNNLZCc6mew": {
+ "id": "OTUk_CtpKBitRate",
+ "uml-id": "_wgRHcO6wEeCjNNLZCc6mew",
+ "enum": [
+ "2.5_G",
+ "10_G",
+ "40_G",
+ "100_G"
+ ],
+ "is-read-only": false,
+ "description": [
+ "Provides an enumeration with the meaning of each k value."
+ ]
+ },
+ "_6Y_gEO6wEeCjNNLZCc6mew": {
+ "id": "OTUk_CtpProblemList",
+ "uml-id": "_6Y_gEO6wEeCjNNLZCc6mew",
+ "enum": [
+ "LOF",
+ "AIS",
+ "LOM"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_xHNWMO6xEeCjNNLZCc6mew": {
+ "id": "OTUk_TtpProblemList",
+ "uml-id": "_xHNWMO6xEeCjNNLZCc6mew",
+ "enum": [
+ "TIM",
+ "DEG",
+ "BDI",
+ "SSF"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The valid list of problems for the entity."
+ ]
+ },
+ "_KRQ3MK8KEeG_zYhfU3oMYg": {
+ "id": "MonitoredDirection",
+ "uml-id": "_KRQ3MK8KEeG_zYhfU3oMYg",
+ "enum": [
+ "SINK",
+ "SOURCE"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The enumeration with the options for directionality for nonintrusive monitoring."
+ ]
+ },
+ "_qBme4LuYEeGeqZLpdvU3BA": {
+ "id": "DegThrType",
+ "uml-id": "_qBme4LuYEeGeqZLpdvU3BA",
+ "enum": [
+ "PERCENTAGE",
+ "NUMBER_ERRORED_BLOCKS"
+ ],
+ "is-read-only": false,
+ "description": [
+ "<p>The value of the threshold can be provisioned in terms of number of errored blocks or in terms of percentage of errored blocks. For percentage-based specification, in order to support provision of less than 1%, the specification consists of two fields. The first field indicates the granularity of percentage. For examples, in 1%, in 0.1%, or in 0.01%, etc. The second field indicates the multiple of the granularity. For number of errored block based, the value is a positive integer.</p>"
+ ]
+ },
+ "_Parz8NwAEeGoneTbGt8X0A": {
+ "id": "LinkType",
+ "uml-id": "_Parz8NwAEeGoneTbGt8X0A",
+ "enum": [
+ "DWDM",
+ "CWDM",
+ "NO_WDM"
+ ],
+ "is-read-only": false
+ },
+ "_V1TuANwAEeGoneTbGt8X0A": {
+ "id": "ApplicationIdentifierType",
+ "uml-id": "_V1TuANwAEeGoneTbGt8X0A",
+ "enum": [
+ "STANDARD",
+ "PROPRIETARY"
+ ],
+ "is-read-only": false
+ },
+ "_yt7S4PzgEeG3u-aQKIiCtg": {
+ "id": "ApsChannel",
+ "uml-id": "_yt7S4PzgEeG3u-aQKIiCtg",
+ "enum": [
+ "PATH",
+ "TCM1",
+ "TCM2",
+ "TCM3",
+ "TCM4",
+ "TCM5",
+ "TCM6",
+ "SECTION"
+ ],
+ "is-read-only": false
+ },
+ "_LG3yQOVVEeKyU85eduW_rA": {
+ "id": "DelayMeasurementRole",
+ "uml-id": "_LG3yQOVVEeKyU85eduW_rA",
+ "enum": [
+ "CONTROLLER",
+ "RESPONDER"
+ ],
+ "is-read-only": false
+ },
+ "_7fy9sJSCEeOLxKCUIYtzCg": {
+ "id": "ResizeOperationType",
+ "uml-id": "_7fy9sJSCEeOLxKCUIYtzCg",
+ "enum": [
+ "INCREASE_BW",
+ "DECREASE_BW"
+ ],
+ "is-read-only": false
+ },
+ "_Y6WUEEamEeabNPX3o7rjtw": {
+ "id": "GranularityPeriodType",
+ "uml-id": "_Y6WUEEamEeabNPX3o7rjtw",
+ "enum": [
+ "UNKNOWN",
+ "PERIOD_15MIN",
+ "PERIOD_24HOURS"
+ ],
+ "is-read-only": false,
+ "description": [
+ "The enumeration with the options for granularity period of the performance data."
+ ]
+ }
+ }
+} \ No newline at end of file