summaryrefslogtreecommitdiffstats
path: root/sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang
diff options
context:
space:
mode:
Diffstat (limited to 'sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang')
-rw-r--r--sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang861
1 files changed, 861 insertions, 0 deletions
diff --git a/sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang b/sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang
new file mode 100644
index 000000000..66f6ade0d
--- /dev/null
+++ b/sdnr/wt/devicemanager-onap/onf14/provider/src/test/resources/currentRevision/ietf-microwave-radio-link@2019-06-19.yang
@@ -0,0 +1,861 @@
+module ietf-microwave-radio-link {
+ yang-version 1.1;
+ namespace "urn:ietf:params:xml:ns:yang:ietf-microwave-radio-link";
+ prefix mrl;
+
+ import ietf-yang-types {
+ prefix yang;
+ reference
+ "RFC 6991";
+ }
+ import iana-if-type {
+ prefix ianaift;
+ }
+ import ietf-interfaces {
+ prefix if;
+ reference
+ "RFC 8343";
+ }
+ import ietf-interface-protection {
+ prefix ifprot;
+ reference
+ "RFC 8561";
+ }
+ import ietf-microwave-types {
+ prefix mw-types;
+ reference
+ "RFC 8561";
+ }
+
+ organization
+ "Internet Engineering Task Force (IETF) CCAMP WG";
+ contact
+ "WG List: <mailto:ccamp@ietf.org>
+
+ Editors:
+ Jonas Ahlberg (jonas.ahlberg@ericsson.com)
+ Min Ye (amy.yemin@huawei.com)
+ Xi Li (Xi.Li@neclab.eu)
+ Daniela Spreafico (daniela.spreafico@nokia.com)
+ Marko Vaupotic (Marko.Vaupotic@aviatnet.com)";
+ description
+ "This is a module for the entities in
+ a generic microwave system.
+
+ Copyright (c) 2019 IETF Trust and the persons identified as
+ authors of the code. All rights reserved.
+
+ Redistribution and use in source and binary forms, with or
+ without modification, is permitted pursuant to, and subject
+ to the license terms contained in, the Simplified BSD License
+ set forth in Section 4.c of the IETF Trust's Legal Provisions
+ Relating to IETF Documents
+ (http://trustee.ietf.org/license-info).
+ This version of this YANG module is part of RFC 8561; see
+ the RFC itself for full legal notices.";
+
+ revision 2019-06-19 {
+ description
+ "Initial revision.";
+ reference
+ "RFC 8561: A YANG Data Model for Microwave Radio Link";
+ }
+
+ feature xpic {
+ description
+ "Indicates that the device supports XPIC.";
+ reference
+ "ETSI TR 102 311";
+ }
+
+ feature mimo {
+ description
+ "Indicates that the device supports MIMO.";
+ reference
+ "ETSI TR 102 311";
+ }
+
+ feature tdm {
+ description
+ "Indicates that the device supports TDM.";
+ }
+
+ typedef power {
+ type decimal64 {
+ fraction-digits 1;
+ }
+ description
+ "Type used for the power values in the data nodes
+ for configuration or status.";
+ }
+
+ container radio-link-protection-groups {
+ description
+ "Configuration of radio link protected groups of
+ carrier terminations in a radio link. More than one
+ protected group per radio link terminal is allowed.";
+ uses ifprot:protection-groups {
+ refine "protection-group/members" {
+ must "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type, 'ianaift:microwaveCarrierTermination')" {
+ description
+ "The type of a protection member must be
+ 'microwaveCarrierTermination'.";
+ }
+ }
+ refine "protection-group/working-entity" {
+ must "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type, 'ianaift:microwaveCarrierTermination')" {
+ description
+ "The type of a working-entity must be
+ 'microwaveCarrierTermination'.";
+ }
+ }
+ }
+ }
+ container xpic-pairs {
+ if-feature "xpic";
+ description
+ "Configuration of carrier termination pairs
+ for operation in XPIC mode.";
+ reference
+ "ETSI TR 102 311";
+ list xpic-pair {
+ key "name";
+ description
+ "List of carrier termination pairs in XPIC mode.";
+ leaf name {
+ type string;
+ description
+ "Name used for identification of the XPIC pair.";
+ }
+ leaf enabled {
+ type boolean;
+ default "false";
+ description
+ "Enable(true)/disable(false) XPIC";
+ }
+ leaf-list members {
+ type if:interface-ref;
+ must "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type, 'ianaift:microwaveCarrierTermination')" {
+ description
+ "The type of a member must be
+ 'microwaveCarrierTermination'.";
+ }
+ min-elements 2;
+ max-elements 2;
+ description
+ "Association to XPIC pairs used in the radio link
+ terminal.";
+ }
+ }
+ }
+ container mimo-groups {
+ if-feature "mimo";
+ description
+ "Configuration of carrier terminations
+ for operation in MIMO mode.";
+ reference
+ "ETSI TR 102 311";
+ list mimo-group {
+ key "name";
+ description
+ "List of carrier terminations in MIMO mode.";
+ leaf name {
+ type string;
+ description
+ "Name used for identification of the MIMO group.";
+ }
+ leaf enabled {
+ type boolean;
+ default "false";
+ description
+ "Enable(true)/disable(false) MIMO.";
+ }
+ leaf-list members {
+ type if:interface-ref;
+ must "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type, 'ianaift:microwaveCarrierTermination')" {
+ description
+ "The type of a member must be
+ 'microwaveCarrierTermination'.";
+ }
+ min-elements 2;
+ description
+ "Association to a MIMO group if used in the radio
+ link terminal.";
+ }
+ }
+ }
+
+ augment "/if:interfaces/if:interface" {
+ when "derived-from-or-self(if:type,'ianaift:microwaveRadioLinkTerminal')";
+ description
+ "Addition of data nodes for the radio link terminal to
+ the standard Interface data model, for interfaces of
+ the type 'microwaveRadioLinkTerminal'.";
+ leaf id {
+ type string;
+ description
+ "Descriptive identity of the radio link terminal used by
+ far-end RLT to check that it's connected to the correct
+ near-end RLT. Does not need to be configured if this
+ check is not used.";
+ }
+ leaf mode {
+ type identityref {
+ base mw-types:rlt-mode;
+ }
+ mandatory true;
+ description
+ "A description of the mode in which the radio link
+ terminal is configured. The format is X plus Y.
+ X represents the number of bonded carrier terminations.
+ Y represents the number of protecting carrier
+ terminations.";
+ }
+ leaf-list carrier-terminations {
+ type if:interface-ref;
+ must "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type, 'ianaift:microwaveCarrierTermination')" {
+ description
+ "The type of interface must be
+ 'microwaveCarrierTermination'.";
+ }
+ min-elements 1;
+ description
+ "A list of references to carrier terminations
+ included in the radio link terminal.";
+ }
+ leaf-list rlp-groups {
+ type leafref {
+ path "/mrl:radio-link-protection-groups/mrl:protection-group/mrl:name";
+ }
+ description
+ "A list of references to the carrier termination
+ groups configured for radio link protection in this
+ radio link terminal.";
+ }
+ leaf-list xpic-pairs {
+ if-feature "xpic";
+ type leafref {
+ path "/mrl:xpic-pairs/mrl:xpic-pair/mrl:name";
+ }
+ description
+ "A list of references to the XPIC pairs used in this
+ radio link terminal. One pair can be used by two
+ terminals.";
+ reference
+ "ETSI TR 102 311";
+ }
+ leaf-list mimo-groups {
+ if-feature "mimo";
+ type leafref {
+ path "/mrl:mimo-groups/mrl:mimo-group/mrl:name";
+ }
+ description
+ "A reference to the MIMO group used in this
+ radio link terminal. One group can be used by more
+ than one terminal.";
+ reference
+ "ETSI TR 102 311";
+ }
+ list tdm-connections {
+ if-feature "tdm";
+ key "tdm-type";
+ description
+ "A list stating the number of active TDM connections
+ of a specified tdm-type that is configured to be
+ supported by the RLT.";
+ leaf tdm-type {
+ type identityref {
+ base mw-types:tdm-type;
+ }
+ description
+ "The type of TDM connection, which also indicates
+ the supported capacity.";
+ }
+ leaf tdm-connections {
+ type uint16;
+ mandatory true;
+ description
+ "Number of connections of the specified type.";
+ }
+ }
+ }
+ augment "/if:interfaces/if:interface" {
+ when "derived-from-or-self(if:type,'ianaift:microwaveCarrierTermination')";
+ description
+ "Addition of data nodes for carrier termination to
+ the standard Interface data model, for interfaces
+ of the type 'microwaveCarrierTermination'.";
+ leaf carrier-id {
+ type string;
+ default "A";
+ description
+ "ID of the carrier (e.g., A, B, C, or D).
+ Used in XPIC and MIMO configurations to check that
+ the carrier termination is connected to the correct
+ far-end carrier termination. Should be the same
+ carrier ID on both sides of the hop. Left as
+ default value when MIMO and XPIC are not in use.";
+ }
+ leaf tx-enabled {
+ type boolean;
+ default "false";
+ description
+ "Disables (false) or enables (true) the transmitter.
+ Only applicable when the interface is enabled
+ (interface:enabled = true); otherwise, it's always
+ disabled.";
+ }
+ leaf tx-oper-status {
+ type enumeration {
+ enum "off" {
+ description
+ "Transmitter is off.";
+ }
+ enum "on" {
+ description
+ "Transmitter is on.";
+ }
+ enum "standby" {
+ description
+ "Transmitter is in standby.";
+ }
+ }
+ config false;
+ description
+ "Shows the operative status of the transmitter.";
+ }
+ leaf tx-frequency {
+ type uint32;
+ units "kHz";
+ mandatory true;
+ description
+ "Selected transmitter frequency.";
+ }
+ choice freq-or-distance {
+ mandatory true;
+ description
+ "A choice to configure rx-frequency directly or compute
+ it as duplex-distance subtracted from tx-frequency.";
+ leaf rx-frequency {
+ type uint32;
+ units "kHz";
+ description
+ "Selected receiver frequency.";
+ }
+ leaf duplex-distance {
+ type int32;
+ units "kHz";
+ description
+ "Distance between transmitter and receiver frequencies.";
+ }
+ }
+ leaf actual-rx-frequency {
+ type uint32;
+ units "kHz";
+ config false;
+ description
+ "Computed receiver frequency.";
+ }
+ leaf actual-duplex-distance {
+ type uint32;
+ units "kHz";
+ config false;
+ description
+ "Computed distance between Tx and Rx frequencies.";
+ }
+ leaf channel-separation {
+ type uint32;
+ units "kHz";
+ mandatory true;
+ description
+ "The amount of bandwidth allocated to a carrier. The
+ distance between adjacent channels in a radio
+ frequency channels arrangement";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ leaf polarization {
+ type enumeration {
+ enum "horizontal" {
+ description
+ "Horizontal polarization.";
+ }
+ enum "vertical" {
+ description
+ "Vertical polarization.";
+ }
+ enum "not-specified" {
+ description
+ "Polarization not specified.";
+ }
+ }
+ default "not-specified";
+ description
+ "Polarization - a textual description for info only.";
+ }
+ choice power-mode {
+ mandatory true;
+ description
+ "A choice of RTPC or ATPC.";
+ container rtpc {
+ description
+ "Remote Transmit Power Control (RTPC).";
+ reference
+ "ETSI EN 302 217-1";
+ leaf maximum-nominal-power {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ mandatory true;
+ description
+ "Selected output power.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ }
+ container atpc {
+ description
+ "Automatic Transmitter Power Control (ATPC).";
+ reference
+ "ETSI EN 302 217-1";
+ leaf maximum-nominal-power {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ mandatory true;
+ description
+ "Selected maximum output power. Minimum output
+ power is the same as the system capability,
+ minimum-power.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ leaf atpc-lower-threshold {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ must "current() <= ../atpc-upper-threshold";
+ mandatory true;
+ description
+ "The lower threshold for the input power at the
+ far end, which is used in the ATPC mode.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ leaf atpc-upper-threshold {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ mandatory true;
+ description
+ "The upper threshold for the input power at the
+ far end, which is used in the ATPC mode.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ }
+ }
+ leaf actual-transmitted-level {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ config false;
+ description
+ "Actual transmitted power level (0.1 dBm resolution).";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf actual-received-level {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ config false;
+ description
+ "Actual received power level (0.1 dBm resolution).";
+ reference
+ "ETSI EN 301 129";
+ }
+ choice coding-modulation-mode {
+ mandatory true;
+ description
+ "A selection of single or
+ adaptive coding/modulation mode.";
+ container single {
+ description
+ "A single modulation order only.";
+ reference
+ "ETSI EN 302 217-1";
+ leaf selected-cm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ mandatory true;
+ description
+ "Selected the single coding/modulation.";
+ }
+ }
+ container adaptive {
+ description
+ "Adaptive coding/modulation.";
+ reference
+ "ETSI EN 302 217-1";
+ leaf selected-min-acm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ mandatory true;
+ description
+ "Selected minimum coding/modulation.
+ Adaptive coding/modulation shall not go
+ below this value.";
+ }
+ leaf selected-max-acm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ mandatory true;
+ description
+ "Selected maximum coding/modulation.
+ Adaptive coding/modulation shall not go
+ above this value.";
+ }
+ }
+ }
+ leaf actual-tx-cm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ config false;
+ description
+ "Actual coding/modulation in transmitting direction.";
+ }
+ leaf actual-snir {
+ type decimal64 {
+ range "0..99";
+ fraction-digits 1;
+ }
+ units "dB";
+ config false;
+ description
+ "Actual signal to noise plus the interference ratio
+ (0.1 dB resolution).";
+ }
+ leaf actual-xpi {
+ if-feature "xpic";
+ type decimal64 {
+ range "0..99";
+ fraction-digits 1;
+ }
+ units "dB";
+ config false;
+ description
+ "The actual carrier to cross-polar interference.
+ Only valid if XPIC is enabled (0.1 dB resolution).";
+ reference
+ "ETSI TR 102 311";
+ }
+ container ct-performance-thresholds {
+ description
+ "Specification of thresholds for when alarms should
+ be sent and cleared for various performance counters.";
+ leaf received-level-alarm-threshold {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ default "-99";
+ description
+ "An alarm is sent when the received power level is
+ below the specified threshold.";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf transmitted-level-alarm-threshold {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ default "-99";
+ description
+ "An alarm is sent when the transmitted power level
+ is below the specified threshold.";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf ber-alarm-threshold {
+ type enumeration {
+ enum "1e-9" {
+ description
+ "Threshold at 1e-9 (10^-9).";
+ }
+ enum "1e-8" {
+ description
+ "Threshold at 1e-8 (10^-8).";
+ }
+ enum "1e-7" {
+ description
+ "Threshold at 1e-7 (10^-7).";
+ }
+ enum "1e-6" {
+ description
+ "Threshold at 1e-6 (10^-6).";
+ }
+ enum "1e-5" {
+ description
+ "Threshold at 1e-5 (10^-5).";
+ }
+ enum "1e-4" {
+ description
+ "Threshold at 1e-4 (10^-4).";
+ }
+ enum "1e-3" {
+ description
+ "Threshold at 1e-3 (10^-3).";
+ }
+ enum "1e-2" {
+ description
+ "Threshold at 1e-2 (10^-2).";
+ }
+ enum "1e-1" {
+ description
+ "Threshold at 1e-1 (10^-1).";
+ }
+ }
+ default "1e-6";
+ description
+ "Specification of at which BER an alarm should
+ be raised.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ }
+ leaf if-loop {
+ type enumeration {
+ enum "disabled" {
+ description
+ "Disables the IF Loop.";
+ }
+ enum "client" {
+ description
+ "Loops the signal back to the client side.";
+ }
+ enum "radio" {
+ description
+ "Loops the signal back to the radio side.";
+ }
+ }
+ default "disabled";
+ description
+ "Enable (client/radio) or disable (disabled)
+ the IF Loop, which loops the signal back to
+ the client side or the radio side.";
+ }
+ leaf rf-loop {
+ type enumeration {
+ enum "disabled" {
+ description
+ "Disables the RF Loop.";
+ }
+ enum "client" {
+ description
+ "Loops the signal back to the client side.";
+ }
+ enum "radio" {
+ description
+ "Loops the signal back to the radio side.";
+ }
+ }
+ default "disabled";
+ description
+ "Enable (client/radio) or disable (disabled)
+ the RF loop, which loops the signal back to
+ the client side or the radio side.";
+ }
+ container capabilities {
+ config false;
+ description
+ "Capabilities of the installed equipment and
+ some selected configurations.";
+ leaf min-tx-frequency {
+ type uint32;
+ units "kHz";
+ description
+ "Minimum Tx frequency possible to use.";
+ }
+ leaf max-tx-frequency {
+ type uint32;
+ units "kHz";
+ description
+ "Maximum Tx frequency possible to use.";
+ }
+ leaf min-rx-frequency {
+ type uint32;
+ units "kHz";
+ description
+ "Minimum Rx frequency possible to use.";
+ }
+ leaf max-rx-frequency {
+ type uint32;
+ units "kHz";
+ description
+ "Maximum Tx frequency possible to use.";
+ }
+ leaf minimum-power {
+ type power;
+ units "dBm";
+ description
+ "The minimum output power supported.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ leaf maximum-available-power {
+ type power;
+ units "dBm";
+ description
+ "The maximum output power supported.";
+ reference
+ "ETSI EN 302 217-1";
+ }
+ leaf available-min-acm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ description
+ "Minimum coding-modulation possible to use.";
+ }
+ leaf available-max-acm {
+ type identityref {
+ base mw-types:coding-modulation;
+ }
+ description
+ "Maximum coding-modulation possible to use.";
+ }
+ }
+ container error-performance-statistics {
+ config false;
+ description
+ "ITU-T G.826 error performance statistics relevant for
+ a microwave/millimeter wave carrier.";
+ leaf bbe {
+ type yang:counter32;
+ units "number of block errors";
+ description
+ "Number of Background Block Errors (BBEs). A BBE is an
+ errored block not occurring as part of Severely Errored
+ Seconds (SES). Discontinuities in the value of this
+ counter can occur at re-initialization of the management
+ system and at other times as indicated by the value of
+ 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ITU-T G.826";
+ }
+ leaf es {
+ type yang:counter32;
+ units "seconds";
+ description
+ "Number of Errored Seconds (ES). An ES is a one-second
+ period with one or more errored blocks or at least one
+ defect. Discontinuities in the value of this counter
+ can occur at re-initialization of the management system
+ and at other times as indicated by the value of
+ 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ITU-T G.826";
+ }
+ leaf ses {
+ type yang:counter32;
+ units "seconds";
+ description
+ "Number of SES. SES is a one-second period that contains
+ equal or more than 30% errored blocks or at least
+ one defect. SES is a subset of ES. Discontinuities in
+ the value of this counter can occur at re-initialization
+ of the management system and at other times as indicated
+ by the value of 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ITU-T G.826";
+ }
+ leaf uas {
+ type yang:counter32;
+ units "seconds";
+ description
+ "Number of Unavailable Seconds (UAS); that is, the
+ total time that the node has been unavailable.
+ Discontinuities in the value of this counter can occur
+ at re-initialization of the management system and at
+ other times as indicated by the value of
+ 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ITU-T G.826";
+ }
+ }
+ container radio-performance-statistics {
+ config false;
+ description
+ "ETSI EN 301 129 radio physical interface statistics relevant
+ for a carrier termination.";
+ leaf min-rltm {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ description
+ "Minimum received power level. Discontinuities in the
+ value of this counter can occur at re-initialization
+ of the management system and at other times as
+ indicated by the value of 'discontinuity-time' in
+ ietf-interfaces.";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf max-rltm {
+ type power {
+ range "-99..-20";
+ }
+ units "dBm";
+ description
+ "Maximum received power level. Discontinuities in the
+ value of this counter can occur at re-initialization
+ of the management system and at other times as
+ indicated by the value of 'discontinuity-time' in
+ ietf-interfaces.";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf min-tltm {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ description
+ "Minimum transmitted power level. Discontinuities
+ in the value of this counter can occur at
+ re-initialization of the management system and
+ at other times as indicated by the value of
+ 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ETSI EN 301 129";
+ }
+ leaf max-tltm {
+ type power {
+ range "-99..99";
+ }
+ units "dBm";
+ description
+ "Maximum transmitted power level. Discontinuities
+ in the value of this counter can occur at
+ re-initialization of the management system and
+ at other times as indicated by the value of
+ 'discontinuity-time' in ietf-interfaces.";
+ reference
+ "ETSI EN 301 129";
+ }
+ }
+ }
+} \ No newline at end of file