diff options
author | highstreetherbert <herbert.eiselt@highstreet-technologies.com> | 2020-07-15 15:44:23 +0200 |
---|---|---|
committer | highstreetherbert <herbert.eiselt@highstreet-technologies.com> | 2020-07-15 19:05:46 +0200 |
commit | 25b3759a0907d06e0d8e391f751c6fcf067087f5 (patch) | |
tree | f9cd6de6e685216c44f4c44cc7f220f3f23f22c5 /sdnr/wt/data-provider/model/src/main/yang | |
parent | 002ad417b90882524276d1b9cfe377c6f6293a4c (diff) |
SDN-R data-provider with ES7
Extend to ES 7.x and DB setup
Issue-ID: SDNC-1288
Signed-off-by: highstreetherbert <herbert.eiselt@highstreet-technologies.com>
Change-Id: Id7778322b793bfa7472a14a90bc0d1fd953c8c73
Signed-off-by: highstreetherbert <herbert.eiselt@highstreet-technologies.com>
Diffstat (limited to 'sdnr/wt/data-provider/model/src/main/yang')
-rw-r--r-- | sdnr/wt/data-provider/model/src/main/yang/data-provider@2019-08-01.yang (renamed from sdnr/wt/data-provider/model/src/main/yang/data-provider.yang) | 52 |
1 files changed, 32 insertions, 20 deletions
diff --git a/sdnr/wt/data-provider/model/src/main/yang/data-provider.yang b/sdnr/wt/data-provider/model/src/main/yang/data-provider@2019-08-01.yang index ef65104e5..46505cd8f 100644 --- a/sdnr/wt/data-provider/model/src/main/yang/data-provider.yang +++ b/sdnr/wt/data-provider/model/src/main/yang/data-provider@2019-08-01.yang @@ -1,5 +1,5 @@ module data-provider { - + yang-version 1.1; namespace "urn:opendaylight:params:xml:ns:yang:data-provider"; prefix odluxprovider; @@ -191,7 +191,7 @@ module data-provider { } enum NtsManager { description - "Simulation of device"; + "Manage adapter to simulate devices"; } enum Nonsupported { description @@ -201,6 +201,18 @@ module data-provider { description "Device type at this point of time unknown"; } + enum O-RAN-FH { + description + "implements RAN according to o-ran*.yang fro for fronthaule"; + } + enum O-ROADM { + description + "implements Open ROADM"; + } + enum O1-TR069 { + description + "implements O1 RAN interface according to TR069"; + } } description "An enumeration as identification of the device."; @@ -272,7 +284,7 @@ module data-provider { } } description - "The enumeration with the options for granularity period of the + "The enumeration with the options for granularity period of the performance data similar to g.874.1-model"; } @@ -466,7 +478,7 @@ module data-provider { type string; mandatory true; description - "Key to get/set configuration entry in database. Normally Mountpoint + "Key to get/set configuration entry in database. Normally Mountpoint name is used as key id of node."; } leaf node-id { @@ -559,7 +571,7 @@ module data-provider { grouping pmdata-microwave { description - "Consolidated performance information of all microwave model interface + "Consolidated performance information of all microwave model interface PACs"; leaf es { type int32; @@ -855,7 +867,7 @@ module data-provider { default "-99"; config false; description - "Lowest temperature (in degree Celsius) of the radio module inside the + "Lowest temperature (in degree Celsius) of the radio module inside the outdoor unit."; } leaf rf-temp-max { @@ -864,7 +876,7 @@ module data-provider { default "-99"; config false; description - "Highest temperature (in degree Celsius) of the radio module inside the + "Highest temperature (in degree Celsius) of the radio module inside the outdoor unit."; } leaf rf-temp-avg { @@ -873,7 +885,7 @@ module data-provider { default "-99"; config false; description - "Averaged temperature (in degree Celsius) of the radio module inside + "Averaged temperature (in degree Celsius) of the radio module inside the outdoor unit."; } leaf defect-blocks-sum { @@ -882,7 +894,7 @@ module data-provider { default "-1"; config false; description - "Total number of blocks that were defect after receiving and could not + "Total number of blocks that were defect after receiving and could not be corrected by the FEC."; } leaf time-period { @@ -904,9 +916,9 @@ module data-provider { default "-1"; config false; description - "Counts the number of Bytes of Ethernet traffic (before header - compression) transmitted within a second and keeps the highest value - within the measurement period. Field to be left blank for all types of + "Counts the number of Bytes of Ethernet traffic (before header + compression) transmitted within a second and keeps the highest value + within the measurement period. Field to be left blank for all types of TDM containers."; } leaf tx-ethernet-bytes-max-m { @@ -915,9 +927,9 @@ module data-provider { default "-1"; config false; description - "Counts the number of Bytes of Ethernet traffic (before header - compression) transmitted within a minute and keeps the highest value - with in the measurement period. Field to be left blank for all types + "Counts the number of Bytes of Ethernet traffic (before header + compression) transmitted within a minute and keeps the highest value + with in the measurement period. Field to be left blank for all types of TDM containers."; } leaf tx-ethernet-bytes-sum { @@ -926,8 +938,8 @@ module data-provider { default "-1"; config false; description - "Total number of Bytes of Ethernet traffic (before header compression) - transmitted (in direction out of the device) during the measurement + "Total number of Bytes of Ethernet traffic (before header compression) + transmitted (in direction out of the device) during the measurement period. Field to be left blank for all types of TDM containers."; } } @@ -970,7 +982,7 @@ module data-provider { grouping inventory-entity { description - "One equipment entity in a list of a network element that could be rack, + "One equipment entity in a list of a network element that could be rack, card, backplane, module"; leaf id { type string; @@ -996,7 +1008,7 @@ module data-provider { leaf uuid { type string; description - "Unique inventory id of this node for this equipment, provided by + "Unique inventory id of this node for this equipment, provided by network element"; } leaf-list contained-holder { @@ -1022,7 +1034,7 @@ module data-provider { leaf date { type string; description - "manufactured-thing/equipment-instance/manufacture-date: Date + "manufactured-thing/equipment-instance/manufacture-date: Date information provided by manufacturer. No specific format. ()"; } leaf version { |