diff options
author | Sandeep Shah <sandeeplinux1068@gmail.com> | 2020-11-06 10:24:53 -0600 |
---|---|---|
committer | Sandeep Shah <sandeeplinux1068@gmail.com> | 2020-11-06 10:44:14 -0600 |
commit | 5bfc361adaf9bb8f71a6de08883c4a2143103ec0 (patch) | |
tree | ff14de2a64ef2ceb208250f19478724124676a40 /sdnr/northbound/ranSlice/model/src/main | |
parent | f1d9bf460d550308211982c83ed6d7e4fdd06507 (diff) |
Model updates for RANSlice YANG
Changed mandatory fields to optional and
corrected definition for gNBId in gNBCUUPFnGrp
Issue-ID: CCSDK-2969
Signed-off-by: SandeepLinux <Sandeep.Shah@ibm.com>
Change-Id: Ic1b5584809f06139303efb410166976e93d542ea
Diffstat (limited to 'sdnr/northbound/ranSlice/model/src/main')
-rw-r--r-- | sdnr/northbound/ranSlice/model/src/main/yang/ran-network@2020-08-06.yang | 39 |
1 files changed, 20 insertions, 19 deletions
diff --git a/sdnr/northbound/ranSlice/model/src/main/yang/ran-network@2020-08-06.yang b/sdnr/northbound/ranSlice/model/src/main/yang/ran-network@2020-08-06.yang index 506565930..db859f40f 100644 --- a/sdnr/northbound/ranSlice/model/src/main/yang/ran-network@2020-08-06.yang +++ b/sdnr/northbound/ranSlice/model/src/main/yang/ran-network@2020-08-06.yang @@ -612,7 +612,7 @@ module ran-network { leaf-list nfType { type NfType; config false; - min-elements 1; + // min-elements 1; description "Type of the Network Function"; } @@ -714,13 +714,13 @@ module ran-network { "TS 28.622"; leaf host { type inet:host; - mandatory true; + // mandatory true; description "TODO"; } leaf port { type inet:port-number; - mandatory true; + // mandatory true; description "TODO"; } @@ -733,13 +733,13 @@ module ran-network { "TS 23.658"; leaf mcc { type Mcc; - mandatory true; + // mandatory true; description "TODO"; } leaf mnc { type Mnc; - mandatory true; + // mandatory true; description "TODO"; } @@ -867,7 +867,7 @@ module ran-network { leaf-list managedElementTypeList { type string; config false; - min-elements 1; + // min-elements 1; description "The type of functionality provided by the ManagedElement. It may represent one ME functionality or a combination of @@ -971,12 +971,12 @@ module ran-network { grouping SliceProfile{ leaf sliceProfileId{ type string; - mandatory true; + // mandatory true; description "slice profile id"; } leaf sNSSAI{ type SNssai; - mandatory false; + // mandatory false; description "The S-NSSAI may include both the SST and SD fields (in which case the S-NSSAI length is 32 bits in total), or the S-NSSAI may just include the SST field (in which case the S-NSSAI length is 8 bits only)"; } leaf maxNumberofUEs{ @@ -1180,7 +1180,7 @@ module ran-network { } list pLMNInfoList { key "mcc mnc"; - min-elements 1; + // min-elements 1; description "The PLMNInfoList is a list of PLMNInfo data type. It defines which PLMNs that can be served by the NR cell, and which S-NSSAIs that can be supported by the NR cell for @@ -1315,7 +1315,7 @@ module ran-network { } leaf-list nRSectorCarrierRef { type DistinguishedName; - min-elements 1; + // min-elements 1; description "Reference to corresponding NRSectorCarrier instance."; } @@ -1482,14 +1482,15 @@ module ran-network { "'gNB-CU-UP ID' in subclause 9.3.1.15 of 3GPP TS 38.463"; } leaf gNBId { - type int32 { - range "22..32"; + type int64 { + range "0..4294967295"; } mandatory false; description - "Indicates the number of bits for encoding the gNB Id."; + "Identifies a gNB within a PLMN. The gNB Identifier (gNB ID) + is part of the NR Cell Identifier (NCI) of the gNB cells."; reference - "gNB Id in 3GPP TS 38.300, Global gNB ID in 3GPP TS 38.413"; + "gNB ID in 3GPP TS 38.300, Global gNB ID in 3GPP TS 38.413"; } list pLMNInfoList { key "mcc mnc"; @@ -1559,8 +1560,8 @@ module ran-network { } list pLMNId { key "mcc mnc"; - min-elements 1; - max-elements 1; + // min-elements 1; + // max-elements 1; description "The PLMN identifier to be used as part of the global RAN node identity."; @@ -1614,7 +1615,7 @@ module ran-network { } list pLMNInfoList { key "mcc mnc"; - min-elements 1; + // min-elements 1; description "The PLMNInfoList is a list of PLMNInfo data type. It defines which PLMNs that can be served by the NR cell, and which S-NSSAIs that can be supported by the @@ -1990,8 +1991,8 @@ module ran-network { } list sAP { key "host port"; - min-elements 1; - max-elements 1; + // min-elements 1; + // max-elements 1; description "The service access point of the managed NF service instance"; uses SAP; |