diff options
author | Herbert Eiselt <herbert.eiselt@highstreet-technologies.com> | 2019-04-03 17:24:29 +0200 |
---|---|---|
committer | Dan Timoney <dtimoney@att.com> | 2019-04-09 14:13:29 +0000 |
commit | 092189e83c4bd470b9232380dd1a33c63a035606 (patch) | |
tree | 5d296af1e01f79b0d05dd1fec29c3ba78229c54b /docs/guides/onap-user/pnfFault.rst | |
parent | 3ebc1c63fb2e5c62eb52da140cc326fbc271aab0 (diff) |
SDN-R read2docs
Add docs folder and project with src
Change-Id: I0299c5984c747a40a8dd1e3f79479b9e9d729d50
Issue-ID: SDNC-683
Signed-off-by: Herbert Eiselt <herbert.eiselt@highstreet-technologies.com>
Diffstat (limited to 'docs/guides/onap-user/pnfFault.rst')
-rw-r--r-- | docs/guides/onap-user/pnfFault.rst | 59 |
1 files changed, 59 insertions, 0 deletions
diff --git a/docs/guides/onap-user/pnfFault.rst b/docs/guides/onap-user/pnfFault.rst new file mode 100644 index 000000000..ff3a1ac47 --- /dev/null +++ b/docs/guides/onap-user/pnfFault.rst @@ -0,0 +1,59 @@ +.. contents:: + :depth: 3 +.. + +Fault Management +================ + +To operate a network, it is important to get an overview about the +currently raised alarms. The application offers basic fault management +of devices supporting ONF-TR-532. The alarms are classified according to +the severity level (warning, minor, major, critical). + +Views +----- + +The graphical user interface is separated in three views. + +Current Alarms +~~~~~~~~~~~~~~ + +It list all current active faults in the network. In addition it also +list alarms sent by the SDN controller itself, which detects connections +losses to the NetConf server (connectionLossOAM) or which detects +connection loss to a devices via a mediator to a device +(connectionLossNeOAM). + +Alarm Notifications +~~~~~~~~~~~~~~~~~~~ + +As long as the view is open, it lists all alarm notification reached by +the SDN Controller. Please note that refreshing the view will start the +collection again. Previous alarm notification can be viewed in the alarm +log. + +Alarm Log +~~~~~~~~~ + +Next to the current active alarms an alarm log lists all alarm +notifications of the past. + +Implementation +-------------- + +The application has two parts. While the server is listening for NetConf +notifications to store them in the database the client retrieves the +information from the database and displays them in a grid view. + +The server synchronizes with the current alarm lists of the devices and +calculates based on raise and clear notifications the current alarm +status of the network. The current alarms are stored in a database. In +addition all Problem Notifications received by the SDN controller are +stored. There is no logic implemented on the client. + +An alarm status bar on top of each graphical user interface informs the +operator about the health status of the network. + +The OpenDaylight DLUX web application uses web sockets for updating the +graphical user interface in case of Problem Notification (devices) and +Connection Status Notifications (ODL). |