Requirement Changes Introduced in Casablanca
========================================================
This document summarizes the requirement changes by section that were
introduced between the Beijing release and
Casablanca release. Click on the requirement number to
navigate to the
.. contents::
:depth: 2
Summary of Changes
------------------
* **Requirements Added:** 70
* **Requirements Changed:** 187
* **Requirements Removed:** 61
Contrail Resource Parameters > Contrail Network Parameters > External Networks
------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-02164`
When a VNF's Heat Orchestration Template's Contrail resource
has a property that
references an external network that requires the network's
Fully Qualified Domain Name (FQDN), the property parameter
* **MUST** follow the format ``{network-role}_net_fqdn``
* **MUST** be declared as type ``string``
* **MUST NOT** be enumerated in the VNF's Heat Orchestration Template's
Environment File
Heat > Cinder Volumes
---------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-79531
The VNF Heat Orchestration Template **MUST** define
"outputs" in the volume template for each Cinder volume
resource universally unique identifier (UUID) (i.e. ONAP
Volume Template Output Parameters).
Heat > Heat Orchestration Template Format > Heat Orchestration Template Structure > resources > metadata
--------------------------------------------------------------------------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-97199
A VNF's Heat Orchestration Template's OS::Nova::Server
resource **MUST** contain the attribute "metadata".
Heat > Heat Template Constructs > Heat Files Support (get_file)
---------------------------------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-62177
When using the intrinsic function get_file, the included files
**MUST** have unique file names within the scope of the VNF.
Heat > Heat Template Constructs > Nested Heat Template Requirements
-------------------------------------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-89868
The VNF Heat Orchestration Template **MUST** have unique
file names within the scope of the VNF for a nested heat yaml file.
Heat > Networking > External Networks
-------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-29865
When a VNF connects to an external network, a network role,
referred to as the '{network-role}' **MUST** be assigned to the
external network for use in the VNF's Heat Orchestration Template.
Heat > Networking > Internal Networks
-------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-34726
If a VNF's port is connected to an internal network and the port
is created in the same Heat Orchestration Template as the internal network,
then the port resource **MUST** use a 'get_resource' to obtain
the network UUID.
Heat > ONAP Resource ID and Parameter Naming Convention > Contrail Resource Parameters > Contrail Network Parameters > External Networks
----------------------------------------------------------------------------------------------------------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-73228
A VNF's Heat Orchestration Template's parameter
'{network-role}_net_fqdn'
**MUST** be declared as type 'string'.
Heat > ONAP Resource ID and Parameter Naming Convention > Resource: OS::Nova::Server – Metadata Parameters > vm_role
--------------------------------------------------------------------------------------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-46823
A VNF's Heat Orchestration Template's OS::Nova::Server
Resource metadata map value parameter 'vnf_name' **MUST** be
either
- enumerated in the VNF's Heat Orchestration
Template's environment file.
- hard coded in the VNF's Heat Orchestration
Template's OS::Nova::Resource metadata property.
Heat > ONAP Support of Environment Files
----------------------------------------
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-22656
The VNF Heat Orchestration Template **MUST** have a
corresponding environment file for a Cinder Volume Module.
.. container:: note
R-35727
The VNF Heat Orchestration Template **MUST** have a
corresponding environment file for an Incremental module.
.. container:: note
R-67205
The VNF Heat Orchestration Template **MUST** have a corresponding
environment file for a Base Module.
Monitoring & Management > Data Structure Specification of the Event Record
--------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-120182`
The xNF provider **MUST** indicate specific conditions that may arise, and
recommend actions that may be taken at specific thresholds, or if specific
conditions repeat within a specified time interval, using the semantics and
syntax described by the :doc:`VES Event Registration specification<../../../../vnfsdk/module.git/files/VESEventRegistration_3_0>`.
.. container:: note
:need:`R-123044`
The xNF Provider **MAY** require that specific events, identified by their
``eventName``, require that certain fields, which are optional in the common
event format, must be present when they are published.
.. container:: note
:need:`R-520802`
The xNF provider **MUST** provide a YAML file formatted in adherence with
the :doc:`VES Event Registration specification<../../../../vnfsdk/module.git/files/VESEventRegistration_3_0>`
that defines the following information for each event produced by the VNF:
* ``eventName``
* Required fields
* Optional fields
* Any special handling to be performed for that event
.. container:: note
:need:`R-570134`
The events produced by the xNF **MUST** must be compliant with the common
event format defined in the
:doc:`VES Event Listener<../../../../vnfsdk/model.git/docs/files/VESEventListener_7_0_1>`
specification.
Monitoring & Management > Event Records - Data Structure Description > Common Event Header
------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-528866`
The VNF **MUST** produce VES events that include the following mandatory
fields in the common event header.
* ``domain`` - the event domain enumeration
* ``eventId`` - the event key unique to the event source
* ``eventName`` - the unique event name
* ``lastEpochMicrosec`` - the latest unix time (aka epoch time) associated
with the event
* ``priority`` - the processing priority enumeration
* ``reportingEntityName`` - name of the entity reporting the event or
detecting a problem in another xNF
* ``sequence`` - the ordering of events communicated by an event source
* ``sourceName`` - name of the entity experiencing the event issue, which
may be detected and reported by a separate reporting entity
* ``startEpochMicrosec`` - the earliest unix time (aka epoch time)
associated with the event
* ``version`` - the version of the event header
* ``vesEventListenerVersion`` - Version of the VES event listener API spec
that this event is compliant with
Monitoring & Management > Event Records - Data Structure Description > Miscellaneous
------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-283988`
The VNF, when publishing events, **MUST NOT** send information through
extensible structures if the event specification has explicitly defined
fields for that information.
.. container:: note
:need:`R-408813`
The VNF, when publishing events, **MUST** pass all information it is
able to collect even if the information field is identified as optional.
However, if the data cannot be collected, then optional fields can be
omitted.
.. container:: note
:need:`R-470963`
The VNF, when publishing events, **MUST** leverage camel case to separate
words and acronyms used as keys that will be sent through extensible fields.
When an acronym is used as the key, then only the first letter shall be
capitalized.
Monitoring & Management > Monitoring & Management Requirements > Asynchronous and Synchronous Data Delivery
-----------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-332680`
The xNF **SHOULD** deliver all syslog messages to the VES Collector per the
specifications in Monitoring and Management chapter.
Monitoring & Management > Monitoring & Management Requirements > Bulk Performance Measurement
---------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-440220`
The xNF **SHOULD** support File transferring protocol, such as FTPES or SFTP,
when supporting the event-driven bulk transfer of monitoring data.
.. container:: note
:need:`R-75943`
The xNF **SHOULD** support the data schema defined in 3GPP TS 32.435, when
supporting the event-driven bulk transfer of monitoring data.
.. container:: note
:need:`R-841740`
The xNF **SHOULD** support FileReady VES event for event-driven bulk transfer
of monitoring data.
Monitoring & Management > Monitoring & Management Requirements > Google Protocol Buffers (GPB)
----------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-257367`
The xNF, when leveraging Google Protocol Buffers for events, **MUST**
serialize the events using native Google Protocol Buffers (GPB) according
to the following guidelines:
* The keys are represented as integers pointing to the system resources
for the xNF being monitored
* The values correspond to integers or strings that identify the
operational state of the VNF resource, such a statistics counters and
the state of an xNF resource.
* The required Google Protocol Buffers (GPB) metadata is provided in the
form of .proto files.
.. container:: note
:need:`R-978752`
The xNF providers **MUST** provide the Service Provider the following
artifacts to support the delivery of high-volume xNF telemetry to
DCAE via GPB over TLS/TCP:
* A valid VES Event .proto definition file, to be used validate and
decode an event
* A valid high volume measurement .proto definition file, to be used for
processing high volume events
* A supporting PM content metadata file to be used by analytics
applications to process high volume measurement events
Monitoring & Management > Monitoring & Management Requirements > JSON
---------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-19624`
The xNF, when leveraging JSON for events, **MUST** encode and serialize
content delivered to ONAP using JSON (RFC 7159) plain text format.
High-volume data is to be encoded and serialized using
`Avro `_, where the Avro [#7.4.1]_ data
format are described using JSON.
Monitoring & Management > Monitoring & Management Requirements > Reporting Frequency
------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-146931`
The xNF **MUST** report exactly one Measurement event per period
per source name.
Monitoring & Management > Monitoring & Management Requirements > VNF telemetry via standardized interface
---------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-821473`
The xNF MUST produce heartbeat indicators consisting of events containing
the common event header only per the VES Listener Specification.
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-51910
The xNF **MUST** provide all telemetry (e.g., fault event
records, syslog records, performance records etc.) to ONAP using the
model, format and mechanisms described in this section.
Monitoring & Management > Transports and Protocols Supporting Resource Interfaces
---------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-798933`
The xNF **SHOULD** deliver event records that fall into the event domains
supported by VES.
.. container:: note
:need:`R-821839`
The xNF **MUST** deliver event records to ONAP using the common transport
mechanisms and protocols defined in this document.
.. container:: note
:need:`R-932071`
The xNF provider **MUST** reach agreement with the Service Provider on
the selected methods for encoding, serialization and data delivery
prior to the on-boarding of the xNF into ONAP SDC Design Studio.
Monitoring & Management > Transports and Protocols Supporting Resource Interfaces > Bulk Telemetry Transmission
---------------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-908291`
The XNF **MAY** leverage bulk xNF telemetry transmission mechanism, as
depicted in Figure 4, in instances where other transmission methods are not
practical or advisable.
Monitoring & Management > Transports and Protocols Supporting Resource Interfaces > xNF Telemetry using Google Protocol Buffers
-------------------------------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-697654`
The xNF **MAY** leverage the Google Protocol Buffers (GPB) delivery model
depicted in Figure 3 to support real-time performance management (PM) data.
In this model the VES events are streamed as binary-encoded GBPs over via
TCP sockets.
Monitoring & Management > Transports and Protocols Supporting Resource Interfaces > xNF Telemetry using VES/JSON Model
----------------------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-659655`
The xNF **SHOULD** leverage the JSON-driven model, as depicted in Figure 2,
for data delivery unless there are specific performance or operational
concerns agreed upon by the Service Provider that would warrant using an
alternate model.
ONAP Heat Cinder Volumes
------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-270358`
A VNF's Heat Orchestration Template's Cinder Volume Template **MUST**
contain either
* An ``OS::Cinder::Volume`` resource
* An ``OS::Heat::ResourceGroup`` resource that references a Nested YAML
file that contains an ``OS::Cinder::Volume`` resource
* A resource that defines the property ``type`` as a Nested YAML file
(i.e., static nesting) and the Nested YAML contains
an ``OS::Cinder::Volume`` resource
ONAP Heat Heat Template Constructs > Heat Files Support (get_file)
------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-76718`
If a VNF's Heat Orchestration Template uses the intrinsic function
``get_file``, the ``get_file`` target **MUST** be referenced in
the Heat Orchestration Template by file name.
.. container:: note
:need:`R-41888`
A VNF's Heat Orchestration Template intrinsic function
``get_file`` **MUST NOT** utilize URL-based file retrieval.
.. container:: note
:need:`R-87848`
When using the intrinsic function get_file, ONAP does not support
a directory hierarchy for included files. All files must be in a
single, flat directory per VNF. A VNF's Heat Orchestration
Template's ``get_file`` target files **MUST** be in the same
directory hierarchy as the VNF's Heat Orchestration Templates.
.. container:: note
:need:`R-05050`
A VNF's Heat Orchestration Templates intrinsic function
``get_file`` **MAY** be used:
* more than once in a VNF's Heat Orchestration Template
* in two or more of a VNF's Heat Orchestration Templates
* in a VNF's Heat Orchestration Templates nested YAML file
ONAP Heat Heat Template Constructs > Nested Heat Templates > Nested Heat Template Requirements
----------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-70112`
A VNF's Heat Orchestration Template **MUST** reference a Nested YAML
file by name. The use of ``resource_registry`` in the VNF's Heat
Orchestration Templates Environment File **MUST NOT** be used.
ONAP Heat Networking > External Networks
----------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-00606`
A VNF **MAY** be connected to zero, one or more than one external
network.
ONAP Heat Networking > Internal Networks
----------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-52425`
A VNF's port connected to an internal network **MUST**
use the port for the purpose of reaching VMs in the same VNF.
.. container:: note
:need:`R-87096`
A VNF **MAY** contain zero, one or more than one internal network.
.. container:: note
:need:`R-46461`
A VNF's port connected to an internal network **MUST NOT** use the port
for the purpose of reaching VMs in another VNF and/or an
external gateway and/or
external router.
ONAP Heat Orchestration Template Format
---------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-92635`
A VNF's Heat Orchestration Template **MUST** be compliant with the
OpenStack Template Guide.
ONAP Heat Orchestration Template Format > Environment File Format
-----------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-86285`
A VNF's Heat Orchestration template **MUST** have a
corresponding environment file.
.. container:: note
:need:`R-03324`
A VNF's Heat Orchestration template's Environment File **MUST**
contain the ``parameters:`` section.
.. container:: note
:need:`R-68198`
A VNF's Heat Orchestration template's Environment File's
``parameters:`` section **MAY** (or **MAY NOT**) enumerate parameters.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > parameters
--------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-90279`
A VNF Heat Orchestration's template's parameter **MUST** be used
in a resource with the exception of the parameters for the
``OS::Nova::Server`` resource property ``availability_zone``.
.. container:: note
:need:`R-91273`
A VNF Heat Orchestration's template's parameter for the
``OS::Nova::Server`` resource property ``availability_zone``
**MAY NOT** be used in any ``OS::Nova::Server``.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > parameters > constraints
----------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-79817`
A VNF's Heat Orchestration Template's parameter defined
in a non-nested YAML file as
type ``comma_delimited_list`` **MAY** have a parameter constraint defined.
.. container:: note
:need:`R-00011`
A VNF's Heat Orchestration Template's parameter defined
in a nested YAML file
**MUST NOT** have a parameter constraint defined.
.. container:: note
:need:`R-96227`
A VNF's Heat Orchestration Template's parameter defined
in a non-nested YAML file as type
``json`` **MAY** have a parameter constraint defined.
.. container:: note
:need:`R-88863`
A VNF's Heat Orchestration Template's parameter defined
in a non-nested YAML file as type
``number`` **MUST** have a parameter constraint of ``range`` or
``allowed_values`` defined.
.. container:: note
:need:`R-40518`
A VNF's Heat Orchestration Template's parameter defined
in a non-nested YAML file as type
``string`` **MAY** have a parameter constraint defined.
.. container:: note
:need:`R-06613`
A VNF's Heat Orchestration Template's parameter defined
in a non-nested YAML file as type
``boolean`` **MAY** have a parameter constraint defined.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > parameters > default
------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-26124`
If a VNF Heat Orchestration Template parameter has a default value,
it **MUST** be enumerated in the environment file.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > parameters > type
---------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-11441`
A VNF's Heat Orchestration Template's parameter type **MUST** be one of
the following values:
* ``string``
* ``number``
* ``json``
* ``comma_delimited_list``
* ``boolean``
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > resources
-------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-40551`
A VNF's Heat Orchestration Template's Nested YAML files **MAY**
(or **MAY NOT**) contain the section ``resources:``.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > resources > deletion_policy
-------------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-43740`
VNF's Heat Orchestration Template's Resource **MAY** declare the
attribute ``deletion_policy:``.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > resources > external_id
---------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-78569`
VNF's Heat Orchestration Template's Resource **MAY** declare the
attribute ``external_id:``.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > resources > metadata
------------------------------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-67386`
A VNF's Heat Orchestration Template's Resource **MAY** declare the
attribute ``metadata``.
ONAP Heat Orchestration Template Format > Heat Orchestration Template Structure > resources > properties
--------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-10834`
If a VNF's Heat Orchestration Template resource attribute
``property:`` uses a nested ``get_param``, the nested
``get_param`` **MUST** reference an index.
ONAP Heat Orchestration Templates Overview > ONAP Heat Orchestration Template Filenames > Base Modules
------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-81339`
A VNF Heat Orchestration Template's Base Module file name **MUST** include
case insensitive 'base' in the filename and
**MUST** match one of the following four
formats:
1.) ``base_.y[a]ml``
2.) ``_base.y[a]ml``
3.) ``base.y[a]ml``
4.) ``_base_``.y[a]ml
where ```` **MUST** contain only alphanumeric characters and
underscores '_' and **MUST NOT** contain the case insensitive word ``base``.
ONAP Heat Orchestration Templates Overview > ONAP Heat Orchestration Template Filenames > Cinder Volume Modules
---------------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-82732`
A VNF Heat Orchestration Template's Cinder Volume Module **MUST**
be named identical to the base or incremental module it is supporting with
``_volume`` appended.
.. container:: note
:need:`R-31141`
VNF Heat Orchestration Template's Cinder Volume Module's Environment File
**MUST** be named identical to the VNF Heat Orchestration Template's
Cinder Volume Module with ``.y[a]ml`` replaced with ``.env``.
ONAP Heat Orchestration Templates Overview > ONAP Heat Orchestration Template Filenames > Incremental Modules
-------------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-87247`
VNF Heat Orchestration Template's Incremental Module file name
**MUST** contain only alphanumeric characters and underscores
'_' and **MUST NOT** contain the case insensitive word ``base``.
ONAP Heat Orchestration Templates Overview > ONAP Heat Orchestration Template Filenames > Nested Heat file
----------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-76057`
VNF Heat Orchestration Template's Nested YAML file name **MUST** contain
only alphanumeric characters and underscores '_' and
**MUST NOT** contain the case insensitive word ``base``.
ONAP Heat Orchestration Templates Overview > ONAP VNF Modularity Overview
-------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-11200`
A VNF's Cinder Volume Module, when it exists, **MUST** be 1:1
with a Base module or Incremental module.
.. container:: note
:need:`R-33132`
A VNF's Heat Orchestration Template **MAY** be
1.) Base Module Heat Orchestration Template (also referred to as a
Base Module),
2.) Incremental Module Heat Orchestration Template (referred to as
an Incremental Module), or
3.) a Cinder Volume Module Heat Orchestration Template (referred to as
Cinder Volume Module).
.. container:: note
:need:`R-37028`
A VNF **MUST** be composed of one Base Module
.. container:: note
:need:`R-20974`
At orchestration time, the VNF's Base Module **MUST**
be deployed first, prior to any incremental modules.
.. container:: note
:need:`R-81725`
A VNF's Incremental Module **MUST** have a corresponding Environment File
.. container:: note
:need:`R-53433`
A VNF's Cinder Volume Module **MUST** have a corresponding environment file
.. container:: note
:need:`R-38474`
A VNF's Base Module **MUST** have a corresponding Environment File.
ONAP Heat Orchestration Templates Overview > Output Parameters > ONAP Volume Module Output Parameters
-----------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-07443`
A VNF's Heat Orchestration Templates' Cinder Volume Module Output
Parameter's name and type **MUST** match the input parameter name and type
in the corresponding Base Module or Incremental Module unless the Output
Parameter is of the type ``comma_delimited_list``, then the corresponding
input parameter **MUST** be declared as type ``json``.
.. container:: note
:need:`R-89913`
A VNF's Heat Orchestration Template's Cinder Volume Module Output
Parameter(s)
**MUST** include the
UUID(s) of the Cinder Volumes created in template,
while others **MAY** be included.
ONAP Heat VNF Modularity
------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-61001`
A shared Heat Orchestration Template resource is a resource that **MUST**
be defined in the base module and will be referenced by one or
more resources in one or more incremental modules.
The UUID of the shared resource (created in the base module) **MUST** be
exposed by declaring a parameter in the
``outputs`` section of the base module.
For ECOMP to provided the UUID value of the shared resource to the
incremental module, the parameter name defined in the ``outputs``
section of the base module **MUST** be defined as a parameter
in the ``parameters`` section of the incremental module.
ECOMP will capture the output parameter name and value in the base module
and provide the value to the corresponding parameter(s) in the
incremental module(s).
ONAP Output Parameter Names > Predefined Output Parameters > OAM Management IP Addresses
----------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-48987`
If the VNF's OAM Management IP Address is cloud assigned and
and the OAM IP Address is required to be inventoried in ONAP A&AI,
then the parameter **MUST** be obtained by the
resource ``OS::Neutron::Port``
attribute ``ip_address``.
.. container:: note
:need:`R-56287`
If the VNF's OAM Management IP Address is assigned by ONAP SDN-C and
assigned in the VNF's Heat Orchestration Template's via a heat resource
``OS::Neutron::Port`` property ``fixed_ips`` map property
``ip_adress`` parameter (e.g., ``{vm-type}_{network-role}_ip_{index}``,
``{vm-type}_{network-role}_v6_ip_{index}``)
and the OAM IP Address is required to be inventoried in ONAP A&AI,
then the parameter **MUST** be echoed in an output statement.
.. code-block:: yaml
outputs:
oam_management_v4_address:
value: {get_param: {vm-type}_{network-role}_ip_{index} }
oam_management_v6_address:
value: {get_param: {vm-type}_{network-role}_v6_ip_{index} }
.. container:: note
:need:`R-94669`
If a VNF has one IPv6 OAM Management IP Address and the
IP Address needs to be inventoried in ONAP's A&AI
database, an output parameter **MUST** be declared in only one of the
VNF's Heat Orchestration Templates and the parameter **MUST** be named
``oam_management_v6_address``.
ONAP TOSCA VNFD Requirements > TOSCA VNF Descriptor > Capability Types
----------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-67895`
The VNFD provided by VNF vendor may use the below described TOSCA
capabilities. An on-boarding entity (ONAP SDC) **MUST** support them.
**tosca.capabilities.nfv.VirtualBindable**
A node type that includes the VirtualBindable capability indicates
that it can be pointed by **tosca.relationships.nfv.VirtualBindsTo**
relationship type.
**tosca.capabilities.nfv.VirtualLinkable**
A node type that includes the VirtualLinkable capability indicates
that it can be pointed by **tosca.relationships.nfv.VirtualLinksTo**
relationship.
**tosca.capabilities.nfv.ExtVirtualLinkable**
A node type that includes the ExtVirtualLinkable capability
indicates that it can be pointed by
**tosca.relationships.nfv.VirtualLinksTo** relationship.
**Note**: This capability type is used in Casablanca how it does
not exist in the last SOL001 draft
**tosca.capabilities.nfv.VirtualCompute** and
**tosca.capabilities.nfv.VirtualStorage** includes flavours of VDU
ONAP TOSCA VNFD Requirements > TOSCA VNF Descriptor > Data Types
----------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-54356`
The below table includes the data types used by NFV node and is based
on TOSCA/YAML constructs specified in draft GS NFV-SOL 001. The node
data definitions/attributes used in VNFD **MUST** comply with the below
table.
.. container:: note
:need:`R-54876`
The below table describes the data types used for LCM configuration
and is based on TOSCA constructs specified in draft GS NFV-SOL 001.
The LCM configuration data elements used in VNFD **MUST** comply
with the below table.
ONAP TOSCA VNFD Requirements > TOSCA VNF Descriptor > General
-------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-15837`
The following table defines the major TOSCA Types specified in
ETSI NFV-SOL001 standard draft. The VNFD provided by a VNF vendor
**MUST** comply with the below definitions:
.. container:: note
:need:`R-17852`
The VNFD **MAY** include TOSCA/YAML definitions that are not part of
NFV Profile. If provided, these definitions MUST comply with TOSCA
Simple Profile in YAML v.1.2.
.. container:: note
:need:`R-35854`
The VNF Descriptor (VNFD) provided by VNF vendor **MUST** comply with
TOSCA/YAML based Service template for VNF descriptor specified in
ETSI NFV-SOL001.
**Note**: As the ETSI NFV-SOL001 is work in progress the below tables
summarizes the TOSCA definitions agreed to be part of current version
of NFV profile and that VNFD MUST comply with in ONAP Release 2+
Requirements.
.. container:: note
:need:`R-46527`
A VNFD is a deployment template which describes a VNF in terms of
deployment and operational behavior requirements. It contains
virtualized resources (nodes) requirements as well as connectivity
and interfaces requirements and **MUST** comply with info elements
specified in ETSI GS NFV-IFA 011. The main parts of the VNFD are
the following:
- VNF topology: it is modeled in a cloud agnostic way using virtualized
containers and their connectivity. Virtual Deployment Units (VDU)
describe the capabilities of the virtualized containers, such as
virtual CPU, RAM, disks; their connectivity is modeled with VDU
Connection Point Descriptors (VduCpd), Virtual Link Descriptors
(VnfVld) and VNF External Connection Point Descriptors
(VnfExternalCpd);
- VNF deployment aspects: they are described in one or more
deployment flavours, including configurable parameters, instantiation
levels, placement constraints (affinity / antiaffinity), minimum and
maximum VDU instance numbers. Horizontal scaling is modeled with
scaling aspects and the respective scaling levels in the deployment
flavours;
**Note**: The deployment aspects (deployment flavour etc.) are postponed
for future ONAP releases.
- VNF lifecycle management (LCM) operations: describes the LCM operations
supported per deployment flavour, and their input parameters;
Note, thatthe actual LCM implementation resides in a different layer,
namely referring to additional template artifacts.
.. container:: note
:need:`R-65486`
The VNFD **MUST** comply with ETSI GS NFV-SOL001 document endorsing
the above mentioned NFV Profile and maintaining the gaps with the
requirements specified in ETSI GS NFV-IFA011 standard.
ONAP TOSCA VNFD Requirements > TOSCA VNF Descriptor > Interface Types
---------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-32155`
The VNFD provided by VNF vendor may use the below described TOSCA
interface types. An on-boarding entity (ONAP SDC) **MUST** support them.
**tosca.interfaces.nfv.vnf.lifecycle.Nfv** supports LCM operations
ONAP TOSCA VNFD Requirements > TOSCA VNF Descriptor > Relationship Types
------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-95321`
The VNFD provided by VNF vendor may use the below described TOSCA
relationships. An on-boarding entity (ONAP SDC) **MUST** support them.
**tosca.relationships.nfv.VirtualBindsTo**
This relationship type represents an association relationship between
VDU and CP node types.
**tosca.relationships.nfv.VirtualLinksTo**
This relationship type represents an association relationship between
the VduCpd's and VirtualLinkDesc node types.
ONAP TOSCA VNFD Requirements > VNF CSAR Package > VNF Package Contents
----------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-01123`
The VNF package Manifest file **MUST** contain: VNF package meta-data, a
list of all artifacts (both internal and external) entry's including
their respected URI's, an algorithm to calculate a digest and a digest
result calculated on the content of each artifacts, as specified in
ETSI GS NFV-SOL004. The VNF Package MUST include VNF Identification
Data to uniquely identify the resource for a given VNF provider. The
identification data must include: an identifier for the VNF, the name
of the VNF as was given by the VNF provider, VNF description, VNF
provider, and version.
.. container:: note
:need:`R-10087`
The VNF package **MUST** contain all standard artifacts as specified in
ETSI GS NFV-SOL004 including Manifest file, VNFD (or Main TOSCA/YAML
based Service Template) and other optional artifacts. CSAR Manifest
file as per SOL004 - for example ROOT\\ **MainServiceTemplate.mf**
.. container:: note
:need:`R-21322`
The VNF provider **MUST** provide their testing scripts to support
testing as specified in ETSI NFV-SOL004 - Testing directory in CSAR
.. container:: note
:need:`R-26885`
The VNF provider **MUST** provide the binaries and images needed to
instantiate the VNF (VNF and VNFC images) either as:
- Local artifact in CSAR: ROOT\\Artifacts\\ **VNF_Image.bin**
- externally referred (by URI) artifact in Manifest file (also may be
referred by VNF Descriptor)
Note: Currently, ONAP doesn't have the capability of Image management,
we upload the image into VIM/VNFM manually.
.. container:: note
:need:`R-40820`
The VNF provider MUST enumerate all of the open source licenses
their VNF(s) incorporate. CSAR License directory as per ETSI SOL004.
for example ROOT\\Licenses\\ **License_term.txt**
ONAP TOSCA VNFD Requirements > VNF CSAR Package > VNF Package Structure and Format
----------------------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-51347`
The VNF package **MUST** be arranged as a CSAR archive as specified in
TOSCA Simple Profile in YAML 1.2.
.. container:: note
:need:`R-87234`
The VNF package provided by a VNF vendor **MAY** be either with
TOSCA-Metadata directory (CSAR Option 1) or without TOSCA-Metadata
directory (CSAR Option 2) as specified in ETSI GS NFV-SOL004. On-boarding
entity (ONAP SDC) must support both options.
**Note:** SDC supports only the CSAR Option 1 in Casablanca. The Option 2
will be considered in future ONAP releases,
PNF Plug and Play > PNF Plug and Play
-------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-01427`
The PNF **MUST** support the provisioning of security and authentication
parameters (HTTP username and password) in order to be able to authenticate
with DCAE (in ONAP).
Note: In R3, a username and password are used with the DCAE VES Event
Listener which are used for HTTP Basic Authentication.
Note: The configuration management and provisioning software are specific
to a vendor architecture.
.. container:: note
:need:`R-106240`
The following VES Events **MUST** be supported by the PNF: pnfRegistration
VES Event, HVol VES Event, and Fault VES Event. These are onboarded via
he SDC Design Studio.
Note: these VES Events are emitted from the PNF to support PNF Plug and
Play, High Volume Measurements, and Fault events respectively.
.. container:: note
:need:`R-17624`
The PNF **MAY** support the optional parameters for Service
Configuration Parameters.
Note: These are detailed in the Stage 5 PnP
Note: These parameters are optional, and not all PNFs will support any
or all of these parameters, it is up to the vendor and service provider
to ascertain which ones are supported up to an including all of the ones
that have been defined. Note: It is expected that there will be a growing
list of supported configuration parameters in future releases of ONAP.
.. container:: note
:need:`R-256347`
The PNF **MUST** support the Ansible protocol for a Service Configuration
message exchange between the PNF and PNF Controller (in ONAP).
Note: this exchange may be either Ansible, Chef, or NetConf depending on
the PNF. Note: The PNF Controller may be VF-C, APP-C or SDN-C based on the
PNF and PNF domain. Note: for R3 (Casablanca) only Ansible is supported.
.. container:: note
:need:`R-258352`
The PNF **MUST** support & accept the provisioning of an ONAP contact IP
address (in IPv4 or IPv6 format).
Note: For example, it a possibility is that an external EMS would configure
& provision the ONAP contact IP address to the PNF (in either IPv4 or
IPv6 format). For the PNF Plug and Play Use Case, this IP address is the
service provider's "point of entry" to the DCAE VES Listener.
Note: different service provider's network architecture may also require
special setup to allow an external PNF to contact the ONAP installation.
For example, in the AT&T network, a maintenance tunnel is used to access
ONAP.
.. container:: note
:need:`R-284934`
If the PNF encounters an error authenticating, reaching the ONAP DCAE VES
Event listener or recieves an error response from sending the pnfRegistration
VES Event, it **MAY** log the error, and notify the operator.
Note: the design of how errors are logged, retrieved and reported
will be a vendor-specific architecture. Reporting faults and errors
is also a vendor specific design. It is expected that the PNF shall
have a means to log an error and notify a user when a fault condition
occurs in trying to contact ONAP, authenticate or send a pnfRegistration
event.
.. container:: note
:need:`R-378131`
(Error Case) - If an error is encountered by the PNF during a
Service Configuration exchange with ONAP, the PNF **MAY** log the
error and notify an operator.
.. container:: note
:need:`R-56718`
The PNF Vendor **MAY** provide software version(s) to be supported by PNF
for SDC Design Studio PNF Model. This is set in the PNF Model property
software_versions.
.. container:: note
:need:`R-579051`
The PNF **MAY** support a HTTP connection to the DCAE VES Event Listener.
Note: HTTP is allowed but not recommended.
.. container:: note
:need:`R-638216`
(Error Case) - The PNF **MUST** support a configurable timer to stop the
periodicity sending of the pnfRegistration VES event. If this timer expires
during a Service Configuration exchange between the PNF and ONAP, it
MAY log a time-out error and notify an operator.
Note: It is expected that each vendor will enforce and define a PNF
service configuration timeout period. This is because the PNF cannot
wait indefinitely as there may also be a technician on-site trying to
complete installation & commissioning. The management of the VES event
exchange is also a requirement on the PNF to be developed by the PNF
vendor.
.. container:: note
:need:`R-686466`
The PNF **MUST** support sending a pnfRegistration VES event.
.. container:: note
:need:`R-707977`
When the PNF receives a Service configuration from ONAP, the PNF **MUST**
cease sending the pnfRegistration VES Event.
.. container:: note
:need:`R-763774`
The PNF **MUST** support a HTTPS connection to the DCAE VES Event
Listener.
.. container:: note
:need:`R-793716`
The PNF **MUST** have "ONAP Aware" software which is capable of performing
PNF PnP registration with ONAP. The "ONAP Aware" software is capable of
performing the PNF PnP Registration with ONAP MUST either be loaded
separately or integrated into the PNF software upon physical delivery
and installation of the PNF.
Note: It is up to the specific vendor to design the software management
functions.
.. container:: note
:need:`R-809261`
The PNF **MUST** use a IP address to contact ONAP.
Note: it is expected that an ONAP operator can ascertain the ONAP IP
address or the security gateway to reach ONAP on the VID or ONAP portal
GUI.
Note: The ONAP contact IP address has been previously configured and
provisioned prior to this step.
Note: The ONAP IP address could be provisioned or resolved through
FQDN & DNS.
.. container:: note
:need:`R-894004`
When the PNF sets up a HTTP or HTTPS connection, it **MUST** provide a
username and password to the DCAE VES Collector for HTTP Basic
Authentication.
Note: HTTP Basic Authentication has 4 steps: Request, Authenticate,
Authorization with Username/Password Credentials, and Authentication Status
as per RFC7617 and RFC 2617.
.. container:: note
:need:`R-952314`
If the PNF set up a TLS connection and mutual (two-way) authentication is
being used, then the PNF **MUST** provide its own X.509v3 Certificate to
the DCAE VES Collector for authentication.
Note: This allows TLS authentication by DCAE VES Collector.
Note: The PNF got its X.509 certificate through Enrollment with an
operator certificate authority or a X.509 vendor certificate from the
vendor factory CA.
Note: In R3 three authentication options are supported:
(1) HTTP with Username & Password and no TLS.
(2) HTTP with Username & Password & TLS with two-way certificate
authentication.
(3) HTTP with Username & Password & TLS with server-side
certificate authentication.
.. container:: note
:need:`R-980039`
The PNF **MUST** send the pnfRegistration VES event periodically.
.. container:: note
:need:`R-981585`
The pnfRegistration VES event periodicity **MUST** be configurable.
Note: The PNF uses the service configuration request as a semaphore to
stop sending the pnfRegistration sent. See the requirement PNP-5360
requirement.
Resource IDs
------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-82115`
When a VNF's Heat Orchestration Template's resource is associated with a
single ``{vm-type}``
and a single external network, the Resource ID text **MUST** contain both
the ``{vm-type}``
and the ``{network-role}``
- the ``{vm-type}`` **MUST** appear before the ``{network-role}`` and
**MUST** be separated by an underscore '_'
- e.g., ``{vm-type}_{network-role}``, ``{vm-type}_{index}_{network-role}``
- note that an ``{index}`` value **MAY** separate the ``{vm-type}`` and the
``{network-role}`` and when this occurs underscores **MUST** separate the
three values. (e.g., ``{vm-type}_{index}_{network-role}``).
.. container:: note
:need:`R-82551`
When a VNF's Heat Orchestration Template's resource is associated with a
single ``{vm-type}`` and a single internal network, the Resource ID **MUST**
contain both the ``{vm-type}`` and the ``int_{network-role}`` and
- the ``{vm-type}`` **MUST** appear before the ``int_{network-role}`` and
**MUST** be separated by an underscore '_'
- (e.g., ``{vm-type}_int_{network-role}``,
``{vm-type}_{index}_int_{network-role}``)
- note that an ``{index}`` value **MAY** separate the
``{vm-type}`` and the ``int_{network-role}`` and when this occurs
underscores **MUST** separate the three values.
(e.g., ``{vm-type}_{index}_int_{network-role}``).
.. container:: note
:need:`R-67793`
When a VNF's Heat Orchestration Template's resource is associated
with more than one ``{vm-type}`` and/or more than one internal and/or
external network, the Resource ID **MUST** not contain the ``{vm-type}``
and/or ``{network-role}``/``int_{network-role}``. It also should contain the
term ``shared`` and/or contain text that identifies the VNF.
.. container:: note
:need:`R-98138`
When a VNF's Heat Orchestration Template's resource is associated with a
single internal network, the Resource ID **MUST** contain the text
``int_{network-role}``.
Resource IDs > Contrail Heat Resources Resource ID Naming Convention > OS::ContrailV2::VirtualNetwork
-----------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-99110`
A VNF's Heat Orchestration Template's Resource
``OS::ContrailV2::VirtualNetwork`` Resource ID **MUST** use the naming convention
1) ``int_{network-role}_network``
or
2) ``int_{network-role}_RVN`` where RVN represents Resource Virtual
Network
VNF Heat Orchestration Templates can only create internal networks.
There is no ``{index}`` after ``{network-role}`` because ``{network-role}``
**MUST** be unique in the scope of the VNF's
Heat Orchestration Template.
Note that option 1 is preferred.
Resource IDs > OpenStack Heat Resources Resource ID Naming Convention > OS::Neutron::Net
----------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-25720`
A VNF's Heat Orchestration Template's Resource ``OS::Neutron::Net``
Resource ID **MUST** use the naming convention
* ``int_{network-role}_network``
VNF Heat Orchestration Templates can only create internal networks.
There is no ``{index}`` after ``{network-role}`` because ``{network-role}``
**MUST** be unique in the scope of the VNF's
Heat Orchestration Template.
Resource: OS::Neutron::Port - Parameters > Introduction > Items to Note
-----------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-48880`
If a VNF's Port is attached to an external network and the port's
IP addresses are assigned by ONAP's SDN-Controller,
the ``OS::Neutron::Port`` Resource's
* property ``fixed_ips`` map property ``ip_address`` **MUST** be used
* property ``fixed_ips`` map property ``subnet``
**MUST NOT** be used
.. container:: note
:need:`R-45602`
If a VNF's Port is attached to a network (internal or external)
and the port's IP addresses are cloud assigned by OpenStack's DHCP
Service, the ``OS::Neutron::Port`` Resource's
* property ``fixed_ips`` map property ``ip_address`` **MUST NOT** be used
* property ``fixed_ips`` map property ``subnet``
**MAY** be used
.. container:: note
:need:`R-70964`
If a VNF's Port is attached to an internal network and the port's
IP addresses are statically assigned by the VNF's Heat Orchestration\
Template (i.e., enumerated in the Heat Orchestration Template's
environment file), the ``OS::Neutron::Port`` Resource's
* property ``fixed_ips`` map property ``ip_address`` **MUST** be used
* property ``fixed_ips`` map property ``subnet``
**MUST NOT** be used
Resource: OS::Neutron::Port - Parameters > Property: allowed_address_pairs, Map Property: ip_address > VIP Assignment, External Networks, Supported by Automation
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-41492`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv4 Virtual IP (VIP)
address is assigned via ONAP automation
using the property ``allowed_address_pairs``
map property ``ip_address`` and
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_floating_ip``
where
* ``{vm-type}`` is the {vm-type} associated with the
OS::Nova::Server
* ``{network-role}`` is the {network-role} of the external
network
And the parameter **MUST** be declared as type ``string``.
.. container:: note
:need:`R-35735`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv6 Virtual IP (VIP)
address is assigned via ONAP automation
using the property ``allowed_address_pairs``
map property ``ip_address``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_floating_v6_ip``
where
* ``{vm-type}`` is the {vm-type} associated with the
OS::Nova::Server
* ``{network-role}`` is the {network-role} of the external
network
And the parameter **MUST** be declared as type ``string``.
Resource: OS::Neutron::Port - Parameters > Property: fixed_ips, Map Property: ip_address
----------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-40971`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv4 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a string,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_ip_{index}``
where
* ``{vm-type}`` is the {vm-type} associated with the
``OS::Nova::Server``
* ``{network-role}`` is the {network-role} of the external
network
* the value for ``{index}`` must start at zero (0) and increment by one
.. container:: note
:need:`R-98569`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_int_{network-role}_v6_ips``
**MUST** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-04697`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv4 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a
``comma_delimited_list``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_ips``
where
* ``{vm-type}`` is the {vm-type} associated with the
``OS::Nova::Server``
* ``{network-role}`` is the {network-role} of the external
network
.. container:: note
:need:`R-90206`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_int_{network-role}_int_ips``
**MUST** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-87123`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_{network-role}_v6_ip_{index}``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-93496`
The VNF's Heat Orchestration Template's Resource ``OS::Neutron::Port``
property ``fixed_ips``
map property ``ip_address``
parameter associated with an internal network, i.e.,
* ``{vm-type}_int_{network-role}_ip_{index}``
* ``{vm-type}_int_{network-role}_v6_ip_{index}``
* ``{vm-type}_int_{network-role}_ips``
* ``{vm-type}_int_{network-role}_v6_ips``
**MUST** be enumerated in the Heat Orchestration
Template's Environment File and IP addresses **MUST** be
assigned.
.. container:: note
:need:`R-85235`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see Requirements R-52425 and R-46461),
and an IPv4 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a
``comma_delimited_list``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_int_{network-role}_ips``
where
* ``{vm-type}`` is the {vm-type} associated with the
``OS::Nova::Server``
* ``{network-role}`` is the {network-role} of the internal
network
.. container:: note
:need:`R-23503`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv6 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a
``comma_delimited_list``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_v6_ips``
where
* ``{vm-type}`` is the {vm-type} associated with the
OS::Nova::Server
* ``{network-role}`` is the {network-role} of the external
network
.. container:: note
:need:`R-27818`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see RRequirements R-52425 and R-46461),
and an IPv6 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a
``string``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_int_{network-role}_v6_ip_{index}``
where
* ``{vm-type}`` is the {vm-type} associated with the
``OS::Nova::Server``
* ``{network-role}`` is the {network-role} of the internal
network
* the value for ``{index}`` must start at zero (0) and increment by one
.. container:: note
:need:`R-71577`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424),
and an IPv6 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a string,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_{network-role}_v6_ip_{index}``
where
* ``{vm-type}`` is the {vm-type} associated with the
OS::Nova::Server
* ``{network-role}`` is the {network-role} of the external
network
* the value for ``{index}`` must start at zero (0) and increment by one
.. container:: note
:need:`R-78380`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see Requirements R-52425 and R-46461),
and an IPv4 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is
defined as a ``string``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_int_{network-role}_ip_{index}``
where
* ``{vm-type}`` is the {vm-type} associated with the
OS::Nova::Server
* ``{network-role}`` is the {network-role} of the internal
network
* the value for ``{index`` must start at zero (0) and increment by one
.. container:: note
:need:`R-28795`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_int_{network-role}_ip_{index}``
**MUST** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-62590`
The VNF's Heat Orchestration Template's Resource ``OS::Neutron::Port``
property ``fixed_ips``
map property ``ip_address``
parameter associated with an external network, i.e.,
* ``{vm-type}_{network-role}_ip_{index}``
* ``{vm-type}_{network-role}_v6_ip_{index}``
* ``{vm-type}_{network-role}_ips``
* ``{vm-type}_{network-role}_v6_ips``
**MUST NOT** be enumerated in the Heat Orchestration
Template's Environment File. ONAP provides the IP address
assignments at orchestration time.
.. container:: note
:need:`R-97201`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_int_{network-role}_v6_ip_{index}``
**MUST** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-29765`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see Requirements R-52425 and R-46461),
and an IPv6 address is assigned
using the property ``fixed_ips``
map property ``ip_address`` and the parameter type is defined as a
``comma_delimited_list``,
the parameter name **MUST** follow the
naming convention
* ``{vm-type}_int_{network-role}_v6_ips``
where
* ``{vm-type}`` is the {vm-type} associated with the
``OS::Nova::Server``
* ``{network-role}`` is the {network-role} of the internal
network
.. container:: note
:need:`R-39841`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``ip_address`` parameter
``{vm-type}_{network-role}_ip_{index}``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
Resource: OS::Neutron::Port - Parameters > Property: fixed_ips, Map Property: subnet
------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-38236`
The VNF's Heat Orchestration Template's
resource ``OS::Neutron::Port`` property ``fixed_ips``
map property ``subnet`` parameter
**MUST** be declared type ``string``.
.. container:: note
:need:`R-76160`
When
* the VNF's Heat Orchestration Template's
resource ``OS::Neutron::Port`` in an Incremental Module is attaching
to an internal network (per the ONAP definition, see Requirements
R-52425 and R-46461)
that is created in the Base Module, AND
* an IPv6 address is being cloud assigned by OpenStack's DHCP Service AND
* the internal network IPv6 subnet is to be specified
using the property ``fixed_ips`` map property ``subnet``,
the parameter **MUST** follow the naming convention
``int_{network-role}_v6_subnet_id``,
where ``{network-role}`` is the network role of the internal network.
Note that the parameter **MUST** be defined as an ``output`` parameter in
the base module.
.. container:: note
:need:`R-22288`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``subnet`` parameter
``int_{network-role}_v6_subnet_id``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-83677`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``subnet`` parameter
``{network-role}_subnet_id``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-15287`
When the VNF's Heat Orchestration Template's
resource ``OS::Neutron::Port`` is attaching
to an external network (per the ONAP definition, see
Requirement R-57424),
and an IPv6 address is being cloud assigned by OpenStack's DHCP Service
and the external network IPv6 subnet is to be specified
using the property ``fixed_ips``
map property ``subnet``, the parameter
**MUST** follow the naming convention
* ``{network-role}_v6_subnet_id``
where
* ``{network-role}`` is the network role of the network.
.. container:: note
:need:`R-84123`
When
* the VNF's Heat Orchestration Template's
resource ``OS::Neutron::Port`` in an Incremental Module is attaching
to an internal network (per the ONAP definition, see
Requirements R-52425 and R-46461)
that is created in the Base Module, AND
* an IPv4 address is being cloud assigned by OpenStack's DHCP Service AND
* the internal network IPv4 subnet is to be specified
using the property ``fixed_ips`` map property ``subnet``,
the parameter **MUST** follow the naming convention
* ``int_{network-role}_subnet_id``
where
* ``{network-role}`` is the network role of the internal network
Note that the parameter **MUST** be defined as an ``output`` parameter in
the base module.
.. container:: note
:need:`R-80829`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``subnet`` parameter
``{network-role}_v6_subnet_id``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-69634`
The VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` property ``fixed_ips``
map property ``subnet`` parameter
``int_{network-role}_subnet_id``
**MUST NOT** be enumerated in the
VNF's Heat Orchestration Template's Environment File.
.. container:: note
:need:`R-62802`
When the VNF's Heat Orchestration Template's
resource ``OS::Neutron::Port`` is attaching
to an external network (per the ONAP definition, see
Requirement R-57424),
and an IPv4 address is being cloud assigned by OpenStack's DHCP Service
and the external network IPv4 subnet is to be specified
using the property ``fixed_ips``
map property ``subnet``, the parameter
**MUST** follow the naming convention
* ``{network-role}_subnet_id``
where
* ``{network-role}`` is the network role of the network.
Resource: OS::Neutron::Port - Parameters > Property: network
------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-62983`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an external network (per the
ONAP definition, see Requirement R-57424), the
``network`` parameter name **MUST**
* follow the naming convention ``{network-role}_net_id`` if the Neutron
network UUID value is used to reference the network
* follow the naming convention ``{network-role}_net_name`` if the
OpenStack network name is used to reference the network.
where ``{network-role}`` is the network-role of the external network
and a ``get_param`` **MUST** be used as the intrinsic function.
.. container:: note
:need:`R-93177`
When the VNF's Heat Orchestration Template's resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see Requirements R-52425 and R-46461),
and the internal network is created in the
same Heat Orchestration Template as the ``OS::Neutron::Port``,
the ``network`` property value **MUST** obtain the UUID
of the internal network by using the intrinsic function
``get_resource``
and referencing the Resource ID of the internal network.
.. container:: note
:need:`R-29872`
The VNF's Heat Orchestration Template's Resource ``OS::Neutron::Port``
property ``network``
parameter **MUST NOT** be enumerated in the Heat Orchestration
Template's Environment File.
.. container:: note
:need:`R-86182`
When the VNF's Heat Orchestration Template's Resource
``OS::Neutron::Port`` is attaching to an internal network (per the
ONAP definition, see Requirements R-52425 and R-46461),
and the internal network is created in a
different Heat Orchestration Template than the ``OS::Neutron::Port``,
the ``network`` parameter name **MUST**
* follow the naming convention ``int_{network-role}_net_id`` if the Neutron
network UUID value is used to reference the network
* follow the naming convention ``int_{network-role}_net_name`` if the
OpenStack network name in is used to reference the network.
where ``{network-role}`` is the network-role of the internal network and
a ``get_param`` **MUST** be used as the intrinsic function.
Resource: OS::Nova::Server - Parameters
---------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-304011`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource's
* Resource ID
* property ``image`` parameter name
* property ``flavor`` parameter name
* property ``name`` parameter name
**MUST** contain the identical ``{vm-type}``
and **MUST** follow the naming conventions defined
in R-58670, R-45188, R-54171, R-87817, and R-29751.
Resource: OS::Nova::Server - Parameters > Property: Name
--------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-663631`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property ``name`` value **MUST** be be obtained via a ``get_param``.
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-51430`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property
``name`` parameter **MUST** be declared as either type ``string``
or type ``comma_delimited_list``.
.. container:: note
:need:`R-54171`
When the VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property ``name`` parameter is defined as a ``string``,
the parameter name **MUST** follow the naming convention
``{vm-type}_name_{index}``, where ``{index}`` is a numeric
value that starts at
zero and increments by one.
.. container:: note
:need:`R-40899`
When the VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property ``name`` parameter is defined as a ``string``, a parameter
**MUST** be delcared for
each ``OS::Nova::Server`` resource associated with the ``{vm-type}``.
Resource: OS::Nova::Server - Parameters > Property: Name > Contrail Issue with Values for OS::Nova::Server Property Name
------------------------------------------------------------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-44271`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property
``name`` parameter value **SHOULD NOT** contain special characters
since the Contrail GUI has a limitation displaying special characters.
However, if special characters must be used, the only special characters
supported are: --- \" ! $ ' (\ \ ) = ~ ^ | @ ` { } [ ] > , . _
Resource: OS::Nova::Server - Parameters > Property: availability_zone
---------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-01359`
A VNF's Heat Orchestration Template that contains an ``OS::Nova:Server``
Resource **MAY** define a parameter for the property
``availability_zone`` that is not utilized in any ``OS::Nova::Server``
resources in the Heat Orchestration Template.
.. container:: note
:need:`R-98450`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property
``availability_zone`` parameter name **MUST** follow the naming convention
``availability_zone_{index}`` where the ``{index}``
**MUST** start at zero and
increment by one.
Resource: OS::Nova::Server - Parameters > Property: flavor
----------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-481670`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property ``flavor`` value **MUST** be be obtained via a ``get_param``.
Resource: OS::Nova::Server - Parameters > Property: image
---------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-901331`
The VNF's Heat Orchestration Template's Resource ``OS::Nova::Server``
property ``image`` value **MUST** be be obtained via a ``get_param``.
Resource: OS::Nova::Server Metadata Parameters > environment_context
--------------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-56183`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata``key/value pair ``environment_context``
parameter ``environment_context`` **MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-20308`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``environment_context``
parameter **MUST** be declared as ``environment_context`` and the
parameter type **MUST** be defined as type: ``string``.
.. container:: note
:need:`R-13194`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``environment_context`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
Resource: OS::Nova::Server Metadata Parameters > vf_module_id
-------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-98374`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource property
``metadata`` key/value pair ``vf_module_id`` parameter ``vf_module_id``
**MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-71493`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` **MUST**
contain the key/value pair ``vf_module_id``
and the value MUST be obtained via a ``get_param``.
.. container:: note
:need:`R-72871`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource property
``metadata`` key/value pair ``vf_module_id`` parameter ``vf_module_id``
**MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
.. container:: note
:need:`R-86237`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vf_module_id`` is passed into a
Nested YAML
file, the key/value pair name ``vf_module_id`` **MUST NOT** change.
.. container:: note
:need:`R-82134`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource property
``metadata`` key/value pair ``vf_module_id`` parameter **MUST**
be declared as ``vf_module_id`` and the parameter **MUST**
be defined as type: ``string``.
Resource: OS::Nova::Server Metadata Parameters > vf_module_index
----------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-37039`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vf_module_index`` parameter
``vf_module_index`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
.. container:: note
:need:`R-50816`
A VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property ``metadata`` **MAY**
contain the key/value pair ``vf_module_index``
and the value **MUST** be obtained via a ``get_param``.
.. container:: note
:need:`R-09811`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vf_module_index`` **MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-55306`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vf_module_index`` **MUST NOT**
be used in a ``OS::Cinder::Volume`` resource and **MUST NOT** be
used in VNF's Volume template;
it is not supported.
.. container:: note
:need:`R-54340`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vf_module_index`` parameter **MUST**
be declared as ``vf_module_index`` and the parameter **MUST** be
defined as type: ``number``.
.. container:: note
:need:`R-22441`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vf_module_index`` is passed into a
Nested YAML file, the key/value pair
``vf_module_index`` **MUST NOT** change.
Resource: OS::Nova::Server Metadata Parameters > vf_module_name
---------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-15480`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vf_module_name`` parameter ``vf_module_name``
**MUST NOT** have parameter constraints defined.
.. container:: note
:need:`R-80374`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vf_module_name``
parameter ``vf_module_name`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
.. container:: note
:need:`R-39067`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vf_module_name`` parameter **MUST** be
declared as ``vf_module_name`` and the parameter **MUST**
be defined as type: ``string``.
.. container:: note
:need:`R-68023`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` **SHOULD**
contain the key/value pair ``vf_module_name`` and the value **MUST**
be obtained via a ``get_param``.
.. container:: note
:need:`R-49177`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vf_module_name`` is passed into a
Nested YAML
file, the key/value pair name ``vf_module_name`` **MUST NOT** change.
Resource: OS::Nova::Server Metadata Parameters > vm_role
--------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-67597`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vm_role`` parameter ``vm_role``
**MUST NOT** have parameter constraints defined.
.. container:: note
:need:`R-86476`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vm_role`` value **MUST**
only contain alphanumeric characters and underscores (i.e., '_').
.. container:: note
:need:`R-70757`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vm_role`` is passed into a Nested
YAML
file, the key/value pair name ``vm_role`` **MUST NOT** change.
.. container:: note
:need:`R-95430`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property
``metadata`` key/value pair ``vm_role`` value is obtained via
``get_param``, the parameter **MUST** be declared as ``vm_role``
and the parameter **MUST** be defined as type: ``string``.
.. container:: note
:need:`R-85328`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource property
``metadata`` **MAY**
contain the key/value pair ``vm_role`` and the value **MUST** be
obtained either via
- ``get_param``
- hard coded in the key/value pair ``vm_role``.
Resource: OS::Nova::Server Metadata Parameters > vnf_id
-------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-55218`
A VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property
``metadata`` key/value pair ``vnf_id`` parameter ``vnf_id`` **MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-37437`
A VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property ``metadata`` **MUST**
contain the key/value pair ``vnf_id``
and the value **MUST** be obtained via a ``get_param``.
.. container:: note
:need:`R-44491`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vnf_id`` is passed into a Nested YAML
file, the key/value pair name ``vnf_id`` **MUST NOT** change.
.. container:: note
:need:`R-07507`
A VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property
``metadata`` key/value pair ``vnf_id`` parameter
**MUST** be declared as ``vnf_id`` and the parameter **MUST**
be defined as type: ``string``.
.. container:: note
:need:`R-20856`
A VNF's Heat Orchestration Template's ``OS::Nova::Server``
resource property
``metadata`` key/value pair ``vnf_id`` parameter ``vnf_id`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
Resource: OS::Nova::Server Metadata Parameters > vnf_name
---------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-36542`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vnf_name`` parameter
``vnf_name`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
.. container:: note
:need:`R-16576`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property
``metadata`` key/value pair ``vnf_name`` is passed into a Nested YAML
file, the key/value pair name ``vnf_name`` **MUST NOT** change.
.. container:: note
:need:`R-44318`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vnf_name``
parameter ``vnf_name`` **MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-72483`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource property
``metadata`` **MUST** contain the key/value pair ``vnf_name`` and the
value **MUST** be obtained via a ``get_param``.
.. container:: note
:need:`R-62428`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``vnf_name`` parameter **MUST**
be declared as ``vnf_name`` and the parameter **MUST** be defined as
type: ``string``.
Resource: OS::Nova::Server Metadata Parameters > workload_context
-----------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-34055`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``workload_context``
parameter ``workload_context`` **MUST NOT**
have parameter constraints defined.
.. container:: note
:need:`R-75202`
If a VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``workload_context``
is passed into a Nested YAML
file, the key/value pair name ``workload_context`` **MUST NOT** change.
.. container:: note
:need:`R-74978`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``workload_context``
parameter **MUST**
be declared as ``workload_context`` and the parameter **MUST**
be defined as type: ``string``.
.. container:: note
:need:`R-02691`
A VNF's Heat Orchestration Template's ``OS::Nova::Server`` resource
property ``metadata`` key/value pair ``workload_context``
parameter ``workload_context`` **MUST NOT**
be enumerated in the Heat Orchestration Template's environment file.
VNF On-boarding and package management > Resource Description
-------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-22346`
The VNF package MUST provide `VES Event Registration `_ for all VES events provided by that xNF.
VNF On-boarding and package management > Testing
------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-43958`
The xNF Package **MUST** include documentation describing
the tests that were conducted by the xNF provider and the test results.
VNF Resiliency > Virtual Function - Container Recovery Requirements
-------------------------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-46851`
The VNF **MUST** support ONAP Controller's Evacuate command.
.. container:: note
:need:`R-48761`
The VNF **MUST** support ONAP Controller's Snapshot command.
VNF Security > VNF API Security Requirements
--------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-21210`
The VNF **MUST** implement the following input validation control
on APIs: Validate that any input file has a correct and valid
Multipurpose Internet Mail Extensions (MIME) type. Input files
should be tested for spoofed MIME types.
.. container:: note
:need:`R-54930`
The VNF **MUST** implement the following input validation controls:
Do not permit input that contains content or characters inappropriate
to the input expected by the design. Inappropriate input, such as
SQL expressions, may cause the system to execute undesirable and
unauthorized transactions against the database or allow other
inappropriate access to the internal network (injection attacks).
.. container:: note
:need:`R-43884`
The VNF **SHOULD** integrate with the Operator's authentication and
authorization services (e.g., IDAM).
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-02137
The VNF **MUST** implement all monitoring and logging as
described in the Security Analytics section.
.. container:: note
R-15659
The VNF **MUST** restrict changing the criticality level of
a system security alarm to administrator(s).
.. container:: note
R-19367
The VNF **MUST** monitor API invocation patterns to detect
anomalous access patterns that may represent fraudulent access or
other types of attacks, or integrate with tools that implement anomaly
and abuse detection.
.. container:: note
R-19804
The VNF **MUST** validate the CA signature on the certificate,
ensure that the date is within the validity period of the certificate,
check the Certificate Revocation List (CRL), and recognize the identity
represented by the certificate where PKI-based authentication is used.
.. container:: note
R-23772
The VNF **MUST** validate input at all layers implementing VNF APIs.
.. container:: note
R-25878
The VNF **MUST** use certificates issued from publicly
recognized Certificate Authorities (CA) for the authentication process
where PKI-based authentication is used.
.. container:: note
R-37608
The VNF **MUST** provide a mechanism to restrict access based
on the attributes of the VNF and the attributes of the subject.
.. container:: note
R-78066
The VNF **MUST** support requests for information from law
enforcement and government agencies.
.. container:: note
R-87135
The VNF **MUST** comply with NIST standards and industry
best practices for all implementations of cryptography.
VNF Security > VNF Cryptography Requirements
--------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-49109`
The VNF **MUST** support HTTP/S using TLS v1.2 or higher
with strong cryptographic ciphers.
.. container:: note
:need:`R-48080`
The VNF **SHOULD** support an automated certificate management protocol
such as CMPv2, Simple Certificate Enrollment Protocol (SCEP) or
Automated Certificate Management Environment (ACME).
.. container:: note
:need:`R-93860`
The VNF **SHOULD** provide the capability to integrate with an
external encryption service.
VNF Security > VNF Data Protection Requirements
-----------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-58964`
The VNF **MUST** provide the capability to restrict read
and write access to data handled by the VNF.
.. container:: note
:need:`R-95864`
The VNF **MUST** support digital certificates that comply with X.509
standards.
.. container:: note
:need:`R-69610`
The VNF **MUST** provide the capability of using X.509 certificates
issued by an external Certificate Authority.
.. container:: note
:need:`R-73067`
The VNF **MUST** use NIST and industry standard cryptographic
algorithms and standard modes of operations when implementing
cryptography.
.. container:: note
:need:`R-32641`
The VNF **MUST** provide the capability to encrypt data on
non-volatile memory.Non-volative memory is storage that is
capable of retaining data without electrical power, e.g.
Complementary metal-oxide-semiconductor (CMOS) or hard drives.
.. container:: note
:need:`R-70933`
The VNF **MUST** provide the ability to migrate to newer
versions of cryptographic algorithms and protocols with minimal impact.
.. container:: note
:need:`R-12467`
The VNF **MUST NOT** use compromised encryption algorithms.
For example, SHA, DSS, MD5, SHA-1 and Skipjack algorithms.
Acceptable algorithms can be found in the NIST FIPS publications
(https://csrc.nist.gov/publications/fips) and in the
NIST Special Publications (https://csrc.nist.gov/publications/sp).
.. container:: note
:need:`R-02170`
The VNF **MUST** use, whenever possible, standard implementations
of security applications, protocols, and formats, e.g., S/MIME, TLS, SSH,
IPSec, X.509 digital certificates for cryptographic implementations.
These implementations must be purchased from reputable vendors or obtained
from reputable open source communities and must not be developed in-house.
.. container:: note
:need:`R-47204`
The VNF **MUST** be capable of protecting the confidentiality and integrity
of data at rest and in transit from unauthorized access and modification.
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-22645
The VNF **SHOULD** use commercial algorithms only when there
are no applicable governmental standards for specific cryptographic
functions, e.g., public key cryptography, message digests.
.. container:: note
R-99112
The VNF **MUST** provide the capability to restrict access
to data to specific users.
VNF Security > VNF General Security Requirements
------------------------------------------------
Requirements Added
~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-638682`
The VNF **MUST** log any security event required by the VNF Requirements to
Syslog using LOG_AUTHPRIV for any event that would contain sensitive
information and LOG_AUTH for all other relevant events.
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-21819`
The VNF **MUST** provide functionality that enables the Operator to comply
with requests for information from law enforcement and government agencies.
.. container:: note
:need:`R-23882`
The VNF **SHOULD** provide the capability for the Operator to run security
vulnerability scans of the operating system and all application layers.
.. container:: note
:need:`R-92207`
The VNF **SHOULD** provide a mechanism for performing automated
system configuration auditing at configurable time intervals.
.. container:: note
:need:`R-19082`
The VNF **MUST** allow the Operator to disable or remove any security
testing tools or programs included in the VNF, e.g., password cracker,
port scanner.
.. container:: note
:need:`R-40813`
The VNF **SHOULD** support the use of virtual trusted platform
module.
.. container:: note
:need:`R-61354`
The VNF **MUST** provide a mechanism (e.g., access control list) to
permit and/or restrict access to services on the VNF by source,
destination, protocol, and/or port.
.. container:: note
:need:`R-19768`
The VNF **SHOULD** support Layer 3 VPNs that enable segregation of
traffic by application (i.e., AVPN, IPSec VPN for Internet routes).
.. container:: note
:need:`R-69649`
The VNF Provider **MUST** have patches available for vulnerabilities
in the VNF as soon as possible. Patching shall be controlled via change
control process with vulnerabilities disclosed along with
mitigation recommendations.
.. container:: note
:need:`R-99771`
The VNF **MUST** have all code (e.g., QCOW2) and configuration files
(e.g., HEAT template, Ansible playbook, script) hardened, or with
documented recommended configurations for hardening and interfaces that
allow the Operator to harden the VNF. Actions taken to harden a system
include disabling all unnecessary services, and changing default values
such as default credentials and community strings.
.. container:: note
:need:`R-23740`
The VNF **MUST** implement and enforce the principle of least privilege
on all protected interfaces.
.. container:: note
:need:`R-62498`
The VNF **MUST** support encrypted access protocols, e.g., TLS,
SSH, SFTP.
.. container:: note
:need:`R-80335`
For all GUI and command-line interfaces, the VNF **MUST** provide the
ability to present a warning notice that is set by the Operator. A warning
notice is a formal statement of resource intent presented to everyone
who accesses the system.
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-26586
The VNF **SHOULD** support the ability to work with aliases
(e.g., gateways, proxies) to protect and encapsulate resources.
.. container:: note
R-33981
The VNF **SHOULD** interoperate with various access control
mechanisms for the Network Cloud execution environment (e.g.,
Hypervisors, containers).
.. container:: note
R-39342
The VNF **MUST**, if not using the NCSP's IDAM API, comply
with "password changes (includes default passwords)" policy. Products
will support password aging, syntax and other credential management
practices on a configurable basis.
.. container:: note
R-40521
The VNF **MUST**, if not using the NCSP's IDAM API, support
use of common third party authentication and authorization tools such
as TACACS+, RADIUS.
.. container:: note
R-42681
The VNF **MUST** use the NCSP's IDAM API or comply with
the requirements if not using the NCSP's IDAM API, for identification,
authentication and access control of OA&M and other system level
functions.
.. container:: note
R-49956
The VNF **MUST** pass all access to applications (Bearer,
signaling and OA&M) through various security tools and platforms from
ACLs, stateful firewalls and application layer gateways depending on
manner of deployment. The application is expected to function (and in
some cases, interwork) with these security tools.
.. container:: note
R-52085
The VNF **MUST**, if not using the NCSP's IDAM API, provide
the ability to support Multi-Factor Authentication (e.g., 1st factor =
Software token on device (RSA SecureID); 2nd factor = User Name+Password,
etc.) for the users.
.. container:: note
R-55830
The VNF **MUST** distribute all production code from NCSP
internal sources only. No production code, libraries, OS images, etc.
shall be distributed from publically accessible depots.
.. container:: note
R-63217
The VNF **MUST**, if not using the NCSP's IDAM API, support
logging via ONAP for a historical view of "who did what and when."
.. container:: note
R-68589
The VNF **MUST**, if not using the NCSP's IDAM API, support
User-IDs and passwords to uniquely identify the user/application. VNF
needs to have appropriate connectors to the Identity, Authentication
and Authorization systems that enables access at OS, Database and
Application levels as appropriate.
.. container:: note
R-85633
The VNF **MUST** implement Data Storage Encryption
(database/disk encryption) for Sensitive Personal Information (SPI)
and other subscriber identifiable data.
Note: Subscribers SPI/data must be encrypted at rest, and other
subscriber identifiable data should be encrypted at rest. Other
data protection requirements exist and should be well understood
by the developer.
VNF Security > VNF Identity and Access Management Requirements
--------------------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-59391`
The VNF **MUST NOT** not allow the assumption of the permissions of
another account to mask individual accountability.
.. container:: note
:need:`R-15671`
The VNF **MUST** provide access controls that allow the Operator
to restrict access to VNF functions and data to authorized entities.
.. container:: note
:need:`R-75041`
The VNF **MUST**, if not integrated the Operator's Identity and Access
Management system, support configurable password expiration.
.. container:: note
:need:`R-99174`
The VNF **MUST** allow the creation of multiple IDs so that
individual accountability can be supported.
.. container:: note
:need:`R-23135`
The VNF **MUST** authenticate all access to protected GUIs, CLIs,
and APIs.
.. container:: note
:need:`R-46908`
The VNF **MUST**, if not integrated with the Operator's Identity
and Access Management system, comply with "password complexity"
policy. When passwords are used, they shall be complex and shall at
least meet the following password construction requirements: (1) be a
minimum configurable number of characters in length, (2) include 3 of
the 4 following types of characters: upper-case alphabetic, lower-case
alphabetic, numeric, and special, (3) not be the same as the UserID
with which they are associated or other common strings as specified
by the environment, (4) not contain repeating or sequential characters
or numbers, (5) not to use special characters that may have command
functions, and (6) new passwords must not contain sequences of three
or more characters from the previous password.
.. container:: note
:need:`R-42874`
The VNF **MUST** allow the Operator to restrict access based on
the assigned permissions associated with an ID in order to support
Least Privilege (no more privilege than required to perform job
functions).
.. container:: note
:need:`R-98391`
The VNF **MUST**, if not integrated with the Operator's Identity and
Access Management system, support Role-Based Access Control to enforce
least privilege.
.. container:: note
:need:`R-71787`
Each layer of the VNF **MUST** support access restriction
independently of all other layers so that Segregation of Duties
can be implemented.
.. container:: note
:need:`R-79107`
The VNF **MUST**, if not integrated with the Operator's Identity
and Access Management system, support the ability to disable the
userID after a configurable number of consecutive unsuccessful
authentication attempts using the same userID.
.. container:: note
:need:`R-86835`
The VNF **MUST** set the default settings for user access
to deny authorization, except for a super user type of account.
When a VNF is added to the network, nothing should be able to use
it until the super user configures the VNF to allow other users
(human and application) have access.
.. container:: note
:need:`R-85419`
The VNF **SHOULD** support OAuth 2.0 authorization using an external
Authorization Server.
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-05470
The VNF **MUST** host connectors for access to the database layer.
.. container:: note
R-14025
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Session Hijacking.
.. container:: note
R-19790
The VNF **MUST NOT** include authentication credentials
in security audit logs, even if encrypted.
.. container:: note
R-24825
The VNF **MUST** provide Context awareness data (device,
location, time, etc.) and be able to integrate with threat detection system.
.. container:: note
R-29301
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Password Attacks.
.. container:: note
R-31412
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for XSS / CSRF.
.. container:: note
R-31751
The VNF **MUST** subject VNF provider access to privilege
reconciliation tools to prevent access creep and ensure correct
enforcement of access policies.
.. container:: note
R-44032
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Man in the Middle (MITM).
.. container:: note
R-45496
The VNF **MUST** host connectors for access to the OS (Operating System) layer.
.. container:: note
R-49945
The VNF **MUST** authorize VNF provider access through a
client application API by the client application owner and the resource
owner of the VNF before provisioning authorization through Role Based
Access Control (RBAC), Attribute Based Access Control (ABAC), or other
policy based mechanism.
.. container:: note
R-51883
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Replay.
.. container:: note
R-58977
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Eavesdropping.
.. container:: note
R-58998
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Malware (Key Logger).
.. container:: note
R-72243
The VNF **MUST** provide or support the Identity and Access
Management (IDAM) based threat detection data for Phishing / SMishing.
.. container:: note
R-73541
The VNF **MUST** use access controls for VNFs and their
supporting computing systems at all times to restrict access to
authorized personnel only, e.g., least privilege. These controls
could include the use of system configuration or access control
software.
.. container:: note
R-77157
The VNF **MUST** conform to approved request, workflow
authorization, and authorization provisioning requirements when
creating privileged users.
.. container:: note
R-85028
The VNF **MUST** authenticate system to system access and
do not conceal a VNF provider user's individual accountability for
transactions.
.. container:: note
R-89753
The VNF **MUST NOT** install or use systems, tools or
utilities capable of capturing or logging data that was not created
by them or sent specifically to them in production, without
authorization of the VNF system owner.
.. container:: note
R-95105
The VNF **MUST** host connectors for access to the application layer.
VNF Security > VNF Security Analytics Requirements
--------------------------------------------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-74958`
The VNF **MUST** activate security alarms automatically when
it detects an unsuccessful attempt to gain permissions
or assume the identity of another user.
.. container:: note
:need:`R-29705`
The VNF **MUST** restrict changing the criticality level of a
system security alarm to users with administrative privileges.
.. container:: note
:need:`R-43332`
The VNF **MUST** activate security alarms automatically when
it detects the successful modification of a critical system or
application file.
.. container:: note
:need:`R-41825`
The VNF **MUST** activate security alarms automatically when
a configurable number of consecutive unsuccessful login attempts
is reached.
.. container:: note
:need:`R-94525`
The VNF **MUST** log connections to the network listeners of the
resource.
.. container:: note
:need:`R-04492`
The VNF **MUST** generate security audit logs that can be sent
to Security Analytics Tools for analysis.
.. container:: note
:need:`R-07617`
The VNF **MUST** log success and unsuccessful creation, removal, or
change to the inherent privilege level of users.
.. container:: note
:need:`R-34552`
The VNF **MUST** be implemented so that it is not vulnerable to OWASP
Top 10 web application security risks.
.. container:: note
:need:`R-58370`
The VNF **MUST** operate with anti-virus software which produces
alarms every time a virus is detected.
.. container:: note
:need:`R-63330`
The VNF **MUST** detect when its security audit log storage
medium is approaching capacity (configurable) and issue an alarm.
.. container:: note
:need:`R-54520`
The VNF **MUST** log successful and unsuccessful authentication
attempts, e.g., authentication associated with a transaction,
authentication to create a session, authentication to assume elevated
privilege.
.. container:: note
:need:`R-30932`
The VNF **MUST** log successful and unsuccessful access to VNF
resources, including data.
Requirements Removed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
R-08598
The VNF **MUST** log successful and unsuccessful changes to a privilege level.
.. container:: note
R-19219
The VNF **MUST** provide audit logs that include user ID, dates,
times for log-on and log-off, and terminal location at minimum.
.. container:: note
R-20912
The VNF **MUST** support alternative monitoring capabilities
when VNFs do not expose data or control traffic or use proprietary and
optimized protocols for inter VNF communication.
.. container:: note
R-25094
The VNF **MUST** perform data capture for security functions.
.. container:: note
R-31961
The VNF **MUST** support integrated DPI/monitoring functionality
as part of VNFs (e.g., PGW, MME).
.. container:: note
R-56786
The VNF **MUST** implement "Closed Loop" automatic implementation
(without human intervention) for Known Threats with detection rate in low
false positives.
.. container:: note
R-57271
The VNF **MUST** provide the capability of generating security
audit logs by interacting with the operating system (OS) as appropriate.
.. container:: note
R-61648
The VNF **MUST** support event logging, formats, and delivery
tools to provide the required degree of event data to ONAP.
{network-role}
--------------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-96983`
A VNF's Heat Orchestration Template's Resource ID that is associated
with an internal network **MUST** include ``int_{network-role}`` as part
of the Resource ID, where ``int_`` is a hard coded string.
.. container:: note
:need:`R-26506`
A VNF's Heat Orchestration Template's ``{network-role}`` **MUST** contain
only alphanumeric characters and/or underscores '_' and
**MUST NOT** contain any of the following strings:
``_int`` or ``int_`` or ``_int_``.
.. container:: note
:need:`R-84322`
A VNF's Heat Orchestration Template's Resource property parameter that
is associated with an internal network **MUST** include
``int_{network-role}`` as part of the parameter name,
where ``int_`` is a hard coded string.
{vm-type}
---------
Requirements Changed
~~~~~~~~~~~~~~~~~~~~
.. container:: note
:need:`R-01455`
When a VNF's Heat Orchestration Template creates a Virtual Machine
(i.e., ``OS::Nova::Server``),
each "class" of VMs **MUST** be assigned a VNF unique
``{vm-type}``; where "class" defines VMs that
**MUST** have the following identical characteristics:
1.) ``OS::Nova::Server`` resource property ``flavor`` value
2.) ``OS::Nova::Server`` resource property ``image`` value
3.) Cinder Volume attachments
- Each VM in the "class" **MUST** have the identical Cinder Volume
configuration
4.) Network attachments and IP address requirements
- Each VM in the "class" **MUST** have the the identical number of
ports connecting to the identical networks and requiring the identical
IP address configuration.
.. container:: note
:need:`R-82481`
A VNF's Heat Orchestration Template's Resource property parameter that is
associated with a unique Virtual Machine type **MUST** include
``{vm-type}`` as part of the parameter name with two exceptions:
1.) The Resource ``OS::Nova::Server`` property ``availability_zone``
parameter **MUST NOT** be prefixed with a common ``{vm-type}`` identifier,
2.) The Resource ``OS::Nova::Server`` eight mandatory and optional
``metadata``
parameters (i.e., ``vnf_name``, ``vnf_id``, ``vf_module_id``,
``vf_module_name``, ``vm_role``,
``vf_module_index``, ``environment_context``, ``workload_context``)
**MUST NOT** be prefixed with a common ``{vm-type}`` identifier.
.. container:: note
:need:`R-98407`
A VNF's Heat Orchestration Template's ``{vm-type}`` **MUST** contain only
alphanumeric characters and/or underscores '_' and **MUST NOT**
contain any of the following strings:
``_int`` or ``int_`` or ``_int_``.