From 42c920baf4dbb9fe8775843a6d4c9f70fa29f064 Mon Sep 17 00:00:00 2001 From: amitjai Date: Fri, 27 Apr 2018 13:28:57 +0530 Subject: Rename packages from openecomp to onap. This task is all about package name space change also make changes to pom for common module Change-Id: Ie9bda0f958a9a05826c0374830cc9cb7d6d196b6 Issue-ID: SDC-1272 Signed-off-by: amitjai --- .../src/main/resources/MMSC_VF.yaml | 976 +++++++++++++++++++++ 1 file changed, 976 insertions(+) create mode 100644 common/onap-sdc-artifact-generator-lib/onap-sdc-artifact-generator-test/src/main/resources/MMSC_VF.yaml (limited to 'common/onap-sdc-artifact-generator-lib/onap-sdc-artifact-generator-test/src/main/resources/MMSC_VF.yaml') diff --git a/common/onap-sdc-artifact-generator-lib/onap-sdc-artifact-generator-test/src/main/resources/MMSC_VF.yaml b/common/onap-sdc-artifact-generator-lib/onap-sdc-artifact-generator-test/src/main/resources/MMSC_VF.yaml new file mode 100644 index 0000000000..7398e45e95 --- /dev/null +++ b/common/onap-sdc-artifact-generator-lib/onap-sdc-artifact-generator-test/src/main/resources/MMSC_VF.yaml @@ -0,0 +1,976 @@ +tosca_definitions_version: tosca_simple_profile_for_ecomp_1_0 + +description: vMMSC VF Topology Template + +metadata: + invariantUUID: b8643c59-e2c2-4f86-880d-571d4d9d5d22 + UUID: b020ed1e-4bc7-4fc0-ba7e-cc7af6da7ffc + name: vMMC VF + description: | + Delivers messages composed of text, images, and other media types (for example audio and video) + in an operator's network. It is responsible for storing and handling incoming and outgoing Multimedia + Messages (MMs); therefore, acting as an MMS Relay and MMS Server at the same time. + type: VF + category: Mobility + subCategory: MMC + vendor: Nokia + vendorVersion: 6.0.2.14 + + + # reference to template definitions +imports: + - tosca_simple_profile_for_ecomp_1_0.yml + +topology_template: + + # This section provides the parameters which OPENECOMP is not providing values to during + # instantiation. + # It is expected that node template parameters which are not mapped to the Inputs section recieve value from OPENECOMP + # during the orchestration + + inputs: + + node_templates: + + vMMSC: # vMMSC VFC + type: org.openecomp.resource.vfc.Generic + + metadata: + invariantUUID: 673f8d08-2223-4a97-127c-11ab729d23bc + UUID: 2714db52-2116-a3af-1240-a236221ca004 + version: 1.0 + name: vMMC VFC + description: + type: VFC + category: Generic + subCategory: Generic_VFC + vendor: Nokia + vendorVersion: 6.0.2.14 + + properties: + vfc_ecomp_name: true + vfc_instance_name: # to be set by OPENECOMP during instantiation + vfc_type_tag: # from HEAT ENV + vfc_description: vMMSC VFC + vfc_image_name: mmsc-6.0.2_v14.qcow2 # from HEAT / HEAT ENV + vfc_availability_zone: + + + capabilities: + nfv_compute: + properties: + vfc_flavor: mmsc_flavor # from HEAT ENV + scaling: + properties: + min_instances: 5 + max_instances: 5 + initial_instance: + + vNEMS_FE: # vNEMS VFC + type: org.openecomp.resource.vfc.Generic + + metadata: + invariantUUID: 673f8d08-2223-4a97-127c-11ab729d23bc + UUID: 2714db52-2116-a3af-1240-a236221ca004 + version: 1.0 + name: vNEMS_FE VFC + description: | + Legacy support that makes it possible for subscribers without MMS-enabled phones to receive + multimedia messages (MMs) through a web or WAP interface. + E-mail smart push that lets subscribers send and receive MMs to and from the Internet (MM3 interface). + type: VFC + category: Generic_VFC + subCategory: Generic_VFC + vendor: Nokia + vendorVersion: 2.1.2.44 + + properties: + vfc_ecomp_name: true + vfc_instance_name: # to be set by OPENECOMP during instantiation + vfc_type_tag: # from HEAT ENV + vfc_description: vNEMS_FE VFC + vfc_image_name: nems-2.1.2_v44.qcow2 # from HEAT / HEAT ENV + vfc_availability_zone: + + + + capabilities: + nfv_compute: + properties: + vfc_flavor: nems_fe_flavor # from HEAT ENV + scaling: + properties: + min_instances: 2 # set by service designer + max_instances: 4 # set by service designer + + vNEMS_BE: # vNEMS VFC + type: org.openecomp.resource.vfc.Generic + + metadata: + invariantUUID: 673f8d08-2223-4a97-127c-11ab729d23bc + UUID: 2714db52-2116-a3af-1240-a236221ca004 + version: 1.0 + name: vNEMS_BE VFC + description: | + Legacy support that makes it possible for subscribers without MMS-enabled phones to receive + multimedia messages (MMs) through a web or WAP interface. + E-mail smart push that lets subscribers send and receive MMs to and from the Internet (MM3 interface). + type: VFC + category: Generic_VFC + subCategory: Generic_VFC + vendor: Nokia + vendorVersion: 2.1.2.44 + + properties: + vfc_ecomp_name: true + vfc_instance_name: # to be set by OPENECOMP during instantiation + vfc_type_tag: # from HEAT ENV + vfc_description: vNEMS_FE VFC + vfc_image_name: nems-2.1.2_v44.qcow2 # from HEAT / HEAT ENV + vfc_availability_zone: + + + + capabilities: + nfv_compute: + properties: + vfc_flavor: nems_be_flavor # from HEAT ENV + scaling: + properties: + min_instances: 1 # set by service designer + max_instances: 2 # set by service designer + + vECA_TRX: # vNEMS VFC + type: org.openecomp.resource.vfc.Generic + + metadata: + invariantUUID: 673f8d08-2223-4a97-127c-11ab729d23bc + UUID: 2714db52-2116-a3af-1240-a236221ca004 + version: 1.0 + name: vECA_TRX VFC + description: Traffic handling + type: VFC + category: Generic_VFC + subCategory: Generic_VFC + vendor: Nokia + vendorVersion: 13 + + properties: + vfc_ecomp_name: true + vfc_instance_name: # to be set by OPENECOMP during instantiation + vfc_type_tag: # from HEAT ENV + vfc_description: vECA_TRX VFC + vfc_image_name: eca-v13-release.qcow2 # from HEAT / HEAT ENV + vfc_availability_zone: + + + + capabilities: + nfv_compute: + properties: + vfc_flavor: eca_trx_flavor # from HEAT ENV + scaling: + properties: + min_instances: 20 # set by service designer + max_instances: 20 # set by service designer + + vLB: # F5 VFC + type: org.openecomp.resource.vfc.Generic + + metadata: + invariantUUID: 673f8d08-2223-4a97-127c-11ab729d23bc + UUID: 2714db52-2116-a3af-1240-a236221ca004 + version: 1.0 + name: F5 LB VFC + description: Load Balancer + type: VFC + category: Generic + subCategory: Generic_VFC + vendor: F5 Networks + vendorVersion: 11.5.3.163 + + properties: + vfc_ecomp_name: true + vfc_instance_name: # to be set by OPENECOMP during instantiation + vfc_type_tag: # from HEAT ENV + vfc_description: F5 VFC + vfc_image_name: F5-11_5_3-EngHF-34_163.qcow2 # from HEAT / HEAT ENV + vfc_availability_zone: + + + + capabilities: + nfv_compute: + properties: + vfc_flavor: bigip_flavor # from HEAT ENV + scaling: + properties: + min_instances: 2 + max_instances: 2 + + # Internal VF Connection Points (VFCs connection points) + + mmsc_oam: # external OAM CP to mobility OAM network + type: org.openecomp.cp.OAM + + metadata: + invariantUUID: 553f8d08-2223-4a97-127c-11ab729d1234 # generated by ASDC + UUID: ab14db52-2116-a3af-1240-a236221ca82a # generated by ASDC + version: 1.0 # set by ASDC + name: OAM CP + description: OAM CP + type: CP + category: CP + vendor: AT&T + + properties: + address_Info: + ip_address: # provided by OPENECOMP (SDNC) + + + + mmsc_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_fe_oam: # external OAM CP to mobility OAM network + type: org.openecomp.cp.OAM + + metadata: + invariantUUID: 553f8d08-2223-4a97-127c-11ab729d1234 # generated by ASDC + UUID: ab14db52-2116-a3af-1240-a236221ca82a # generated by ASDC + version: 1.0 # set by ASDC + name: OAM CP + description: OAM CP + type: CP + category: CP + vendor: AT&T + + properties: + address_Info: + ip_address: # provided by OPENECOMP (SDNC) + + + + nems_fe_internal: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_fe_imap: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_fe_web: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_fe_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_be_oam: # external OAM CP to mobility OAM network + type: org.openecomp.cp.OAM + + metadata: + invariantUUID: 553f8d08-2223-4a97-127c-11ab729d1234 # generated by ASDC + UUID: ab14db52-2116-a3af-1240-a236221ca82a # generated by ASDC + version: 1.0 # set by ASDC + name: OAM CP + description: OAM CP + type: CP + category: CP + vendor: AT&T + properties: + address_Info: + ip_address: # provided by OPENECOMP (SDNC) + + + nems_be_internal: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + nems_be_imap: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + eca_trx_oam: # external OAM CP to mobility OAM network + type: org.openecomp.cp.OAM + + metadata: + invariantUUID: 553f8d08-2223-4a97-127c-11ab729d1234 # generated by ASDC + UUID: ab14db52-2116-a3af-1240-a236221ca82a # generated by ASDC + version: 1.0 # set by ASDC + name: OAM CP + description: OAM CP + type: CP + category: CP + vendor: AT&T + + properties: + address_Info: + ip_address: # provided by OPENECOMP (SDNC) + + + + eca_trx_internal: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + eca_trx_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_ha: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_mmsc_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_nems_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_nems_web: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_eca_traffic: + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_oam: # external OAM CP to mobility OAM network + type: org.openecomp.cp.OAM + + metadata: + invariantUUID: 553f8d08-2223-4a97-127c-11ab729d1234 # generated by ASDC + UUID: ab14db52-2116-a3af-1240-a236221ca82a # generated by ASDC + version: 1.0 # set by ASDC + name: OAM CP + description: OAM CP + type: CP + category: CP + vendor: AT&T + + properties: + address_Info: + ip_address: # provided by OPENECOMP (SDNC) + + + + lb_dmz_protected: # external CP to mobility DMZ protected network + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + lb_core_direct: # external CP to mobility core direct network + type: org.openecomp.cp.CP + + metadata: + invariantUUID: 55df8d08-2ab3-4a97-127c-11ab729d100a # generated by ASDC + UUID: 12b4db52-2116-b5af-1240-a236221ca145 # generated by ASDC + version: 1.0 # set by ASDC + name: VFC CP + description: VFC CP + type: CP + category: CP + vendor: AT&T + + properties: + address_info: + mac_address: # provided by OPENECOMP (SDNC) + + + + # Intra-VF Virtual Links (Networks) + + mmsc_traffic_net: + type: org.openecomp.resource.vl.VL + + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: MMSC traffic network + description: mmsc traffic network + type: VL + category: VL + vendor: Nokia + properties: + network_type: Tenant_Layer_3 + network_role: Intra-service + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_1 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.253.0.0/17 # HEAT ENV + gateway_ip: 169.253.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + nems_imap_net: + type: org.openecomp.resource.vl.VL + + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: NEMS IMAP network + description: NEMS internal IMAP network + type: VL + category: VL + vendor: Nokia + + properties: + network_type: Tenant_Layer_3 + network_role: Intra-service + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_1 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.253.0.0/17 # HEAT ENV + gateway_ip: 169.253.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + nems_internal_net: + type: org.openecomp.resource.vl.VL + + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: NEMS internal traffic network + description: NEMS internal traffic network + type: VL + category: VL + vendor: Nokia + + properties: + network_type: Tenant_Layer_3 + network_role: Intra-service + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_1 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.253.0.0/17 # HEAT ENV + gateway_ip: 169.253.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + nems_web_net: + type: org.openecomp.resource.vl.VL + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: NEMS web network + description: nems web nwtwork + type: VL + category: VL + vendor: Nokia + properties: + network_type: Tenant_Layer_3 + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_2 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.255.0.0/17 # HEAT ENV + gateway_ip: 169.255.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + nems_traffic_net: + type: org.openecomp.resource.vl.VL + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: NEMS traffic network + description: NEMS traffic network + type: VL + category: VL + vendor: Nokia + properties: + network_type: Tenant_Layer_3 + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + network_name: # provided by OPENECOMP (SDNC) + route_targets: 13979:105717 + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 107.243.37.0/27 # HEAT ENV + gateway_ip: 107.243.37.1 # HEAT ENV + start_ip: 107.243.37.3 # HEAT ENV + end_ip: 107.243.37.30 # HEAT ENV + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + eca_traffic_net: + type: org.openecomp.resource.vl.VL + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: ECA traffic network + description: ECA traffic network + type: VL + category: VL + vendor: Nokia + + properties: + network_type: Tenant_Layer_3 + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + network_name: # provided by OPENECOMP (SDNC) + route_targets: 13979:105719 + network_id: + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 107.243.37.32/24 # HEAT ENV + gateway_ip: 107.243.37.33 # HEAT ENV + start_ip: 107.243.37.35 # HEAT ENV + end_ip: 107.243.37.62 # HEAT ENV + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + eca_internal_net: + type: org.openecomp.resource.vl.VL + + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: ECA internal traffic network + description: ECA internal traffic network + type: VL + category: VL + vendor: Nokia + + properties: + network_type: Tenant_Layer_3 + network_role: Intra-service + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_1 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.253.0.0/17 # HEAT ENV + gateway_ip: 169.253.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP # service level network + + lb_ha_net: + type: org.openecomp.resource.vl.VL + + metadata: + invariantUUID: 14a25c59-e2c2-4f86-880d-371d4d9dc88c + UUID: 1a20ed2e-abcd-3f20-ca4e-cc7af4da1234 + version: 1.0 + name: LB HA network + description: LB sync network + type: VL + category: VL + vendor: Nokia + properties: + network_type: Tenant_Layer_3 + network_role: Intra-service + network_technology: Contrail + network_ecomp_name: false + network_homing: false + network_deployment_node: { get_input: network_deployment_node } + contrail_virtual_network: + vn_name: MME-24474-Ericsson-WTC-lab_int_MMEX36_net_1 + vn_forwarding_mode: l2 + vn_shared: false + vn_external: false + layer_protocol: IP + flow_pattern: E-LAN + test_access: none + l3_access_parameters: + ip_version: 4 + cidr: 169.253.0.0/17 # HEAT ENV + gateway_ip: 169.253.0.3 # HEAT ENV + dhcp_enabled: false # HEAT ENV + capabilities: + virtual_linkable: + valid_source_types: org.openecomp.resource.cp.CP + + + groups: + + # Server Groups for applying placement policy + LbGroup: + type: tosca.groups.Root + members: [vLB] + + mmscGroup: + type: tosca.groups.Root + members: [vMMSC] + + nemas_feGroup: + type: tosca.groups.Root + members: [vNEMS_FE] + + eca_trxGroup: + type: tosca.groups.Root + members: [vECA_TRX] + + # VF Modules + VFModuleMMSC_Expansion: + type: org.openecomp.groups.VfModule + + metadata: + vfModuleModelName: vMMSC::module-1 + vfModuleModelInvariantUUID: adf1a10a-f788-492f-9ea7-7ff91dd55f8c + vfModuleModelUUID: b020dd1e-4bc7-4fc0-ba7e-cc7af6da7ffc + vfModuleModelVersion: 1 + + properties: + vf_module_type: Expansion # set by service designer + vf_module_description: vMMSC growth unit # set by service designer + contrail_service_instance: true # from HEAT + availability_zone_count: 1 # from HEAT + volume_group: false # from HEAT / service Designer + artifacts: # HEAT Templates + - 099a6909-290f-4293-a347-736f11b8ff18 + - 0db84f21-d298-4a4b-b11e-37b92a734066 + + members: + - vMMSC + - vNEMS_FE + - vNEMS_BE + - vECA_TRX + - vLB + - mmsc_oam + - mmsc_traffic + - nems_fe_web + - mmsc_traffic_net + - nems_imap_net + - nems_internal_net + + + policies: + # Autoscaling policy + - mmsc_autoscale_policy: + type: org.openecomp.policy.Autoscaling + + properties: + min_instances: 1 + max_instances: 4 + increment: 1 + factor: bandwidth + threshold: 5 Gpbs + + target: [ VFModuleMMSC_Expansion ] + + # Placement policy + - mmsc_anti_affinity_placement_policy: + type: org.openecomp.policy.Placement + + properties: + conatiner_type: compute + policy: anti_affinity + + target: [ LbGroup, mmscGroup, nemas_feGroup, eca_trxGroup, eca_oamGroup, cmauiGroup ] \ No newline at end of file -- cgit 1.2.3-korg