{ "schema-information": { "instance-number": { "id": "instance-number", "type": "uint16", "order-number": 1, "is-read-only": true, "description": ["There is only one clock per device in the 4th PoC - value 1 should be used as instance-number."] }, "two-step-flag": { "id": "two-step-flag", "type": "boolean", "order-number": 80, "is-read-only": true, "description": ["Indicates whether PTP clock is a two-step clock"] }, "clock-quality": { "id": "clock-quality", "type": "", "order-number": 6, "is-read-only": true, "description": [""] }, "clock-class": { "id": "clock-class", "type": "", "order-number": 7, "is-read-only": true, "description": ["Clock Class acc. to IEEE 1588-2008, 7.6.2.4 and ITU-T G.8275.1, 6.4"] }, "clock-accuracy": { "id": "clock-accuracy", "type": "", "order-number": 8, "is-read-only": true, "description": ["Clock accuracy acc. to IEEE 1588-2008, 7.6.2.5 and ITU-T G.8275.1, 6.3.5"] }, "offset-scaled-log-variance": { "id": "offset-scaled-log-variance", "type": "", "order-number": 9, "is-read-only": true, "description": ["Offset of scaled log variance acc. to IEEE 1588-2008, 7.6.3.5 and ITU-T G.8275.1, 6.3.5"] }, "priority1": { "id": "priority1", "type": "number", "min": 0, "max": 255, "order-number": 10, "is-read-only": true, "description": ["Priority 1 acc. to IEEE 1588-2008, 7.6.2.2"] }, "priority2": { "id": "priority2", "type": "number", "min": 0, "max": 255, "order-number": 11, "is-read-only": false, "description": ["Priority 2 acc. to IEEE 1588-2008, 7.6.2.3"] }, "domain-number": { "id": "domain-number", "type": "number", "min": 24, "max": 43, "order-number": 12, "is-read-only": false, "description": ["PTP domain number acc. to IEEE 1588-2008, 7.1. See ptpDS.domainNumber."] }, "slave-only": { "id": "slave-only", "type": "boolean", "order-number": 81, "is-read-only": false, "description": ["Indicates whether PTP clock may only operate as SC. See IEEE 1588-2008, 9.2."] }, "current-ds": { "id": "current-ds", "type": "", "order-number": 14, "is-read-only": true, "description": [""] }, "steps-removed": { "id": "steps-removed", "type": "", "order-number": 15, "is-read-only": true, "description": ["Number of communication paths traversed between local clock and GM"] }, "offset-from-master": { "id": "offset-from-master", "type": "", "order-number": 16, "is-read-only": true, "unit": "ns*2^16", "description": ["Time off-set from master"] }, "mean-path-delay": { "id": "mean-path-delay", "type": "", "order-number": 17, "is-read-only": true, "unit": "ns*2^16", "description": ["Mean propagation time between master and slave"] }, "parrent-ds": { "id": "parrent-ds", "type": "", "order-number": 18, "is-read-only": true, "description": [""] }, "parent-port-identity": { "id": "parent-port-identity", "type": "", "order-number": 19, "is-read-only": true, "description": [""] }, "parent-stats": { "id": "parent-stats", "type": "", "order-number": 22, "is-read-only": true, "description": ["Indicates whether there are valid parent stats."] }, "observed-parent-offset-scaled-log-variance": { "id": "observed-parent-offset-scaled-log-variance", "type": "", "order-number": 23, "is-read-only": true, "description": ["Estimate of parent's clock PTP variance as observed by slave clock acc. to IEEE 1588-2008, 7.6.4.4."] }, "observed-parent-clock-phase-change-rate": { "id": "observed-parent-clock-phase-change-rate", "type": "", "order-number": 24, "is-read-only": true, "description": ["Estimate of parent's clock PTP phase change rate as observed by slave clock acc. to IEEE 1588-2008, 7.6.4.4."] }, "grandmaster-identity": { "id": "grandmaster-identity", "type": "", "order-number": 25, "is-read-only": true, "description": ["Grandmaster clock ID acc. to IEEE 1588-2008, 7.6.2.1"] }, "grandmaster-clock-quality": { "id": "grandmaster-clock-quality", "type": "", "order-number": 26, "is-read-only": true, "description": [""] }, "grandmaster-priority1": { "id": "grandmaster-priority1", "type": "", "order-number": 30, "is-read-only": true, "description": ["Grandmaster's priority 1 acc. to IEEE 1588-2008, 7.6.2.2"] }, "grandmaster-priority2": { "id": "grandmaster-priority2", "type": "", "order-number": 31, "is-read-only": true, "description": ["Grandmaster's priority 2 acc. to IEEE 1588-2008, 7.6.2.3"] }, "time-properties-ds": { "id": "time-properties-ds", "type": "", "order-number": 32, "is-read-only": true, "description": [""] }, "current-utc-offset-valid": { "id": "current-utc-offset-valid", "type": "", "order-number": 33, "is-read-only": true, "description": ["Indicates wheterh current UTC offset is correct."] }, "current-utc-offset": { "id": "current-utc-offset", "type": "", "order-number": 34, "is-read-only": true, "description": ["Offset between TAI and UTC acc. to IEEE 1588-2008, 7.2.3"] }, "leap59": { "id": "leap59", "type": "", "order-number": 35, "is-read-only": true, "description": ["Inidcates that last minute of current UTC day has 59 seconds."] }, "leap61": { "id": "leap61", "type": "", "order-number": 36, "is-read-only": true, "description": ["Inidcates that last minute of current UTC day has 61 seconds."] }, "time-tracable": { "id": "time-tracable", "type": "", "order-number": 37, "is-read-only": true, "description": ["Indicates that current UTC offset and timescale are traceable to a PRC"] }, "frequency-tracable": { "id": "frequency-tracable", "type": "", "order-number": 38, "is-read-only": true, "description": ["Indicates that frequency determining timescale is traceable to a PRC"] }, "ptp-timescale": { "id": "ptp-timescale", "type": "", "order-number": 39, "is-read-only": true, "description": ["Indicates thet timescale of grandmaster clock is PTP."] }, "time-source": { "id": "time-source", "type": "", "order-number": 40, "is-read-only": true, "description": ["Time source used by grandmaster. See IEEE 1588-2008, 7.6.2.6."] }, "port-state": { "id": "port-state", "type": "", "order-number": 45, "is-read-only": true, "description": ["State of this local port"] }, "log-min-delay-req-interval": { "id": "log-min-delay-req-interval", "type": "", "order-number": 46, "is-read-only": true, "description": ["Minimum permitted mean time interval between successive Delay_Req messages"] }, "peer-mean-path-delay": { "id": "peer-mean-path-delay", "type": "", "order-number": 47, "is-read-only": true, "unit": "ns*2^16", "description": ["Not applicable with this profile"] }, "log-announce-interval": { "id": "log-announce-interval", "type": "", "order-number": 48, "is-read-only": true, "description": ["Mean time interval between successive Announce messages"] }, "announce-receipt-timeout": { "id": "announce-receipt-timeout", "type": "", "order-number": 49, "is-read-only": true, "description": ["Number of announce intervals w/o announce message before timeout acc. to IEEE 1588-2008, 7.7.3.1."] }, "log-sync-interval": { "id": "log-sync-interval", "type": "", "order-number": 50, "is-read-only": true, "description": ["Mean SyncInterval for multicast messages"] }, "delay-mechanism": { "id": "delay-mechanism", "type": "string", "controlType": "text", "order-number": 51, "is-read-only": true, "description": ["Delay mechanism acc. to IEEE 1588-2008, 8.2.5.4.4."] }, "version-number": { "id": "version-number", "type": "", "order-number": 53, "is-read-only": true, "description": ["PTP version used on this port"] }, "transparent-clock-default-ds": { "id": "transparent-clock-default-ds", "type": "", "order-number": 54, "is-read-only": true, "description": [""] }, "number-ports": { "id": "number-ports", "type": "", "order-number": -6, "is-read-only": true, "description": ["Number of ports of the device"] }, "primary-domain": { "id": "primary-domain", "type": "", "order-number": 58, "is-read-only": true, "description": ["Domain number of primary syntonization domain acc. to IEEE 1588-2008, 10.1"] }, "transparent-clock-port-ds-list": { "id": "transparent-clock-port-ds-list", "type": "", "order-number": 59, "is-read-only": true, "description": [""] }, "log-min-pdelay-req-interval": { "id": "log-min-pdelay-req-interval", "type": "", "order-number": 63, "is-read-only": true, "description": ["Not applicable with this profile"] }, "faulty-flag": { "id": "faulty-flag", "type": "", "order-number": 64, "is-read-only": true, "description": ["Indicates whether port is faulty."] }, "default-ds": { "id": "default-ds", "type": "", "order-number": 68, "is-read-only": true, "description": [""] }, "local-priority": { "id": "local-priority", "type": "number", "min": 1, "max": 255, "order-number": 69, "is-read-only": true, "description": ["See ITU-T G.8275.1, 6.3.2."] }, "max-steps-removed": { "id": "max-steps-removed", "type": "number", "min": 1, "max": 255, "order-number": 70, "is-read-only": true, "description": ["See ITU-T G.8275.1, 6.3."] }, "port-ds-list": { "id": "port-ds-list", "type": "", "order-number": 73, "is-read-only": true, "description": [""] }, "clock-identity": { "id": "clock-identity", "type": "", "order-number": -10, "is-read-only": true, "description": ["ID of the local clock"] }, "port-number": { "id": "port-number", "type": "", "order-number": 76, "is-read-only": true, "description": ["Port number of this port on the local clock"] }, "onf-ptp-dataset:master-only": { "id": "onf-ptp-dataset:master-only", "type": "boolean", "order-number": 83, "is-read-only": false, "description": ["Indicates that port can only be a master."] }, "onf-ptp-dataset:local-priority": { "id": "onf-ptp-dataset:local-priority", "type": "number", "min":1, "max":255, "order-number": -2, "is-read-only": false, "description": ["Local priority as used for Alternate BMCA. See ITU-T G.8275.1, 6.3.2."] }, "onf-ptp-dataset:designated-enabled": { "id": "onf-ptp-dataset:designated-enabled", "type": "boolean", "order-number": 82, "is-read-only": false, "description": ["A PTP Port needs to be enabled by management acc. to IEEE 1588-2008, 9.2."] }, "onf-ptp-dataset:delay-asymmetry": { "id": "onf-ptp-dataset:delay-asymmetry", "type": "number", "order-number": 80, "is-read-only": true, "description": ["Known path asymmetry in ns acc. to IEEE 1588-2008, 7.4.2."] }, "onf-ptp-dataset:logical-termination-point": { "id": "onf-ptp-dataset:logical-termination-point ", "type": "string", "order-number": 81, "is-read-only": true, "description": [""] }, "onf-ptp-dataset:multicast-mac-address": { "id": "onf-ptp-dataset:multicast-mac-address", "type": "", "order-number": -5, "is-read-only": true, "description": ["In 4th PoC the value is fixed."] }, "onf-ptp-dataset:max-steps-removed": { "id": "onf-ptp-dataset:max-steps-removed", "type": "number", "min":1, "max":255, "order-number": 70, "is-read-only": false, "description": ["See ITU-T G.8275.1, 6.3."] } } }